Preoperative three-dimensional simulation and clinical evaluation of in-situ bone harvesting in anterior cervical discectomy and fusion surgery.

IF 2.9 2区 医学 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Quantitative Imaging in Medicine and Surgery Pub Date : 2025-03-03 Epub Date: 2025-01-16 DOI:10.21037/qims-24-1726
Chong Chen, Yifan Chen, Yongyu Ye, Guoyan Liang, Wenlin Ye, Yuhui Yang, Yunbing Chang
{"title":"Preoperative three-dimensional simulation and clinical evaluation of <i>in-situ</i> bone harvesting in anterior cervical discectomy and fusion surgery.","authors":"Chong Chen, Yifan Chen, Yongyu Ye, Guoyan Liang, Wenlin Ye, Yuhui Yang, Yunbing Chang","doi":"10.21037/qims-24-1726","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The supplemental harvesting of <i>in-situ</i> bone obtained from cervical vertebrae as cage-filling material in anterior cervical discectomy and fusion (ACDF) results in a good fusion outcome. This study aimed to further quantitatively evaluate the obtainable bone volume and clinical outcomes of cervical <i>in-situ</i> autogenous bone grafting based on a three-dimensional (3D) preoperative simulation.</p><p><strong>Methods: </strong>This study included 78 patients who underwent single-level ACDF. Prior to the surgical procedure, a 3D simulated surgery was performed by constructing several cutting planes in the cervical vertebrae based on Mimics software. The volumes of the harvested <i>in-situ</i> bone graft, including the anterior lip, posterior osteophytes, and Luschka's joint volumes, were measured during the simulated surgery. Immediate postoperative computed tomography (CT) scans were performed to evaluate the efficacy of the preoperative planning. During the postoperative follow-up period, the neurological function and cervical fusion state were also evaluated.</p><p><strong>Results: </strong>The average volume of the cage's bone graft groove was 373.1±74.4 mm<sup>3</sup>, which was lower than that calculated in the preoperative planning (501.6±179.6 mm<sup>3</sup>, P<0.001). In 88.5% (69/78) of the simulated surgery cases, the harvested bone met the volume of the cage's bone graft groove, aligning with the intraoperative scenario. Male patients, elderly patients, patients with lower surgical segments, and patients with higher-grade facet joint degeneration had a more sufficient availability of <i>in-situ</i> autologous bone. The mean follow-up time was 18.02±4.9 months. At the final follow-up, the pain and functional status scores of the patients had improved significantly following surgery (P<0.05).</p><p><strong>Conclusions: </strong>Preoperative planning for ACDF using Mimics software was shown to be both feasible and accurate. The 3D simulated surgery revealed that the majority of patients could supply a sufficient volume of cervical autologous bone for intraoperative grafting. The comprehensive analysis of the <i>in-situ</i> bone harvesting in ACDF provided precise reference data for the clinical implementation.</p>","PeriodicalId":54267,"journal":{"name":"Quantitative Imaging in Medicine and Surgery","volume":"15 3","pages":"1741-1752"},"PeriodicalIF":2.9000,"publicationDate":"2025-03-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11948444/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Quantitative Imaging in Medicine and Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.21037/qims-24-1726","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/16 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The supplemental harvesting of in-situ bone obtained from cervical vertebrae as cage-filling material in anterior cervical discectomy and fusion (ACDF) results in a good fusion outcome. This study aimed to further quantitatively evaluate the obtainable bone volume and clinical outcomes of cervical in-situ autogenous bone grafting based on a three-dimensional (3D) preoperative simulation.

Methods: This study included 78 patients who underwent single-level ACDF. Prior to the surgical procedure, a 3D simulated surgery was performed by constructing several cutting planes in the cervical vertebrae based on Mimics software. The volumes of the harvested in-situ bone graft, including the anterior lip, posterior osteophytes, and Luschka's joint volumes, were measured during the simulated surgery. Immediate postoperative computed tomography (CT) scans were performed to evaluate the efficacy of the preoperative planning. During the postoperative follow-up period, the neurological function and cervical fusion state were also evaluated.

Results: The average volume of the cage's bone graft groove was 373.1±74.4 mm3, which was lower than that calculated in the preoperative planning (501.6±179.6 mm3, P<0.001). In 88.5% (69/78) of the simulated surgery cases, the harvested bone met the volume of the cage's bone graft groove, aligning with the intraoperative scenario. Male patients, elderly patients, patients with lower surgical segments, and patients with higher-grade facet joint degeneration had a more sufficient availability of in-situ autologous bone. The mean follow-up time was 18.02±4.9 months. At the final follow-up, the pain and functional status scores of the patients had improved significantly following surgery (P<0.05).

Conclusions: Preoperative planning for ACDF using Mimics software was shown to be both feasible and accurate. The 3D simulated surgery revealed that the majority of patients could supply a sufficient volume of cervical autologous bone for intraoperative grafting. The comprehensive analysis of the in-situ bone harvesting in ACDF provided precise reference data for the clinical implementation.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Quantitative Imaging in Medicine and Surgery
Quantitative Imaging in Medicine and Surgery Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
4.20
自引率
17.90%
发文量
252
期刊介绍: Information not localized
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信