RISC Fault of Non-Salient Wound-Rotor Synchronous Generator: A Detection Method and Effect Analysis of Insulation

IF 1 4区 工程技术 Q4 ENGINEERING, ELECTRICAL & ELECTRONIC
Kai Sun, Yu-ling He, Xue-wei Wu, Wen Wang, David Gerada, Hong-hua Bai, Wei-ling Huang
{"title":"RISC Fault of Non-Salient Wound-Rotor Synchronous Generator: A Detection Method and Effect Analysis of Insulation","authors":"Kai Sun,&nbsp;Yu-ling He,&nbsp;Xue-wei Wu,&nbsp;Wen Wang,&nbsp;David Gerada,&nbsp;Hong-hua Bai,&nbsp;Wei-ling Huang","doi":"10.1002/tee.24234","DOIUrl":null,"url":null,"abstract":"<p>Rotor interturn short circuit (RISC) fault is one of the most prevalent fault types in the non-salient wound-rotor synchronous generator (WRSG). In the paper, the theoretical mechanism of the RISC fault is studied in detail. Building upon this understanding, from the fault detection and harm consequences, the further work of this article includes proposing a RISC detection method and analyzing the influence of RISC on the insulation thermal damage. On the one hand, a new detection for RISC fault is first proposed based on the phase voltage. The proposed detection method innovatively allows for accurate determination of both the severity and location of RISC faults. On the other hand, the loss and the temperature of the stator core-winding system are comprehensively investigated with varied RISC degrees and positions. The thermal responses of the winding insulation are obtained under the joint action of the external magnetic heat source and the internal electric heat source. The study identifies critical points of insulation vulnerability, particularly noting areas prone to noise and connection joints. This research contributes to the timely online identification of RISC faults and supports preventive maintenance strategies for protecting winding insulation. © 2024 Institute of Electrical Engineers of Japan and Wiley Periodicals LLC.</p>","PeriodicalId":13435,"journal":{"name":"IEEJ Transactions on Electrical and Electronic Engineering","volume":"20 5","pages":"722-735"},"PeriodicalIF":1.0000,"publicationDate":"2024-11-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEJ Transactions on Electrical and Electronic Engineering","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/tee.24234","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Rotor interturn short circuit (RISC) fault is one of the most prevalent fault types in the non-salient wound-rotor synchronous generator (WRSG). In the paper, the theoretical mechanism of the RISC fault is studied in detail. Building upon this understanding, from the fault detection and harm consequences, the further work of this article includes proposing a RISC detection method and analyzing the influence of RISC on the insulation thermal damage. On the one hand, a new detection for RISC fault is first proposed based on the phase voltage. The proposed detection method innovatively allows for accurate determination of both the severity and location of RISC faults. On the other hand, the loss and the temperature of the stator core-winding system are comprehensively investigated with varied RISC degrees and positions. The thermal responses of the winding insulation are obtained under the joint action of the external magnetic heat source and the internal electric heat source. The study identifies critical points of insulation vulnerability, particularly noting areas prone to noise and connection joints. This research contributes to the timely online identification of RISC faults and supports preventive maintenance strategies for protecting winding insulation. © 2024 Institute of Electrical Engineers of Japan and Wiley Periodicals LLC.

无凸极绕线转子同步发电机的RISC故障:一种绝缘检测方法及影响分析
转子匝间短路(RISC)故障是非凸极绕线转子同步发电机(WRSG)中最常见的故障类型之一。本文详细研究了RISC断层的理论机理。在此基础上,从故障检测和危害后果两方面,提出了一种RISC检测方法,并分析了RISC对绝缘热损伤的影响。一方面,首次提出了一种基于相位电压的RISC故障检测方法。提出的检测方法创新地允许准确确定RISC故障的严重程度和位置。另一方面,全面研究了不同RISC度和位置下定子铁芯-绕组系统的损耗和温度。得到了绕组绝缘在外部磁热源和内部电热源共同作用下的热响应。该研究确定了绝缘脆弱的关键点,特别是注意到容易产生噪音和连接接头的区域。该研究有助于实时在线识别RISC故障,并为保护绕组绝缘的预防性维护策略提供支持。©2024日本电气工程师协会和Wiley期刊有限责任公司。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
IEEJ Transactions on Electrical and Electronic Engineering
IEEJ Transactions on Electrical and Electronic Engineering 工程技术-工程:电子与电气
CiteScore
2.70
自引率
10.00%
发文量
199
审稿时长
4.3 months
期刊介绍: IEEJ Transactions on Electrical and Electronic Engineering (hereinafter called TEEE ) publishes 6 times per year as an official journal of the Institute of Electrical Engineers of Japan (hereinafter "IEEJ"). This peer-reviewed journal contains original research papers and review articles on the most important and latest technological advances in core areas of Electrical and Electronic Engineering and in related disciplines. The journal also publishes short communications reporting on the results of the latest research activities TEEE ) aims to provide a new forum for IEEJ members in Japan as well as fellow researchers in Electrical and Electronic Engineering from around the world to exchange ideas and research findings.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信