Percutaneous C1C2 transarticular screw fixation for atlantoaxial osteoarthritis with 3D navigation: technical note and functional outcomes.

IF 1.4 Q3 ORTHOPEDICS
Paul-Emile Borge, Camille Damade, William Gerbeaux, Gaelle Kerdiles, Ibrahim Obeid, Benjamin Bouyer, Olivier Gille, Louis Boissiere
{"title":"Percutaneous C1C2 transarticular screw fixation for atlantoaxial osteoarthritis with 3D navigation: technical note and functional outcomes.","authors":"Paul-Emile Borge, Camille Damade, William Gerbeaux, Gaelle Kerdiles, Ibrahim Obeid, Benjamin Bouyer, Olivier Gille, Louis Boissiere","doi":"10.1007/s00590-025-04254-z","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Atlantoaxial osteoarthritis is a debilitating condition often resistant to conservative management. In refractory cases, C1-C2 fusion becomes a surgical option. Recent advancements, particularly in 3D navigation, have allowed for more precise and minimally invasive approaches, though there are limited reports on isolated percutaneous C1-C2 arthrodesis for osteoarthritis. This study aims to evaluate the feasibility, accuracy, and clinical outcomes of percutaneous C1-C2 transarticular screw fixation using 3D navigation in patients with disabling atlantoaxial osteoarthritis.</p><p><strong>Methods: </strong>Ten patients (median age: 75.5 years), all female, underwent percutaneous C1-C2 screw fixation using the Magerl technique, guided by 3D navigation. Preoperative assessment included CT and contrast-enhanced imaging to ensure safe screw placement. Postoperative evaluations included pain assessment, radiographic analysis, and patient satisfaction.</p><p><strong>Results: </strong>Transarticular screws were inserted in all of patients, with no significant intraoperative complications. Median operative time was 65 min with blood loss under 100 mL. Postoperative pain improved with the median VAS decreasing from 10 preoperatively to 1 at one year. Screw backout was observed in one patient without clinical repercussions. All patients expressed satisfaction and would undergo the procedure again.</p><p><strong>Conclusion: </strong>Percutaneous C1-C2 transarticular screw fixation with 3D navigation is a safe and effective treatment for severe atlantoaxial osteoarthritis. It offers significant pain relief, accurate screw placement, and reduced postoperative morbidity. Preoperative anatomical evaluation remains critical to minimize risks. Level of Evidence Level III, Retrospective Cohort.</p>","PeriodicalId":50484,"journal":{"name":"European Journal of Orthopaedic Surgery and Traumatology","volume":"35 1","pages":"138"},"PeriodicalIF":1.4000,"publicationDate":"2025-03-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Orthopaedic Surgery and Traumatology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s00590-025-04254-z","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Atlantoaxial osteoarthritis is a debilitating condition often resistant to conservative management. In refractory cases, C1-C2 fusion becomes a surgical option. Recent advancements, particularly in 3D navigation, have allowed for more precise and minimally invasive approaches, though there are limited reports on isolated percutaneous C1-C2 arthrodesis for osteoarthritis. This study aims to evaluate the feasibility, accuracy, and clinical outcomes of percutaneous C1-C2 transarticular screw fixation using 3D navigation in patients with disabling atlantoaxial osteoarthritis.

Methods: Ten patients (median age: 75.5 years), all female, underwent percutaneous C1-C2 screw fixation using the Magerl technique, guided by 3D navigation. Preoperative assessment included CT and contrast-enhanced imaging to ensure safe screw placement. Postoperative evaluations included pain assessment, radiographic analysis, and patient satisfaction.

Results: Transarticular screws were inserted in all of patients, with no significant intraoperative complications. Median operative time was 65 min with blood loss under 100 mL. Postoperative pain improved with the median VAS decreasing from 10 preoperatively to 1 at one year. Screw backout was observed in one patient without clinical repercussions. All patients expressed satisfaction and would undergo the procedure again.

Conclusion: Percutaneous C1-C2 transarticular screw fixation with 3D navigation is a safe and effective treatment for severe atlantoaxial osteoarthritis. It offers significant pain relief, accurate screw placement, and reduced postoperative morbidity. Preoperative anatomical evaluation remains critical to minimize risks. Level of Evidence Level III, Retrospective Cohort.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.00
自引率
5.90%
发文量
265
审稿时长
3-8 weeks
期刊介绍: The European Journal of Orthopaedic Surgery and Traumatology (EJOST) aims to publish high quality Orthopedic scientific work. The objective of our journal is to disseminate meaningful, impactful, clinically relevant work from each and every region of the world, that has the potential to change and or inform clinical practice.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信