{"title":"Establishing Diagnostic Reference Levels for Mammography Digital Breast Tomosynthesis, Contrast Enhance, Implants, Spot Compression, Magnification and Stereotactic Biopsy in Dubai Health Sector.","authors":"Entesar Z Dalah, Maryam K Alkaabi, Nisha A Antony, Hashim M Al-Awadhi","doi":"10.3390/jimaging11030079","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of this patient dose review is to establish a thorough diagnostic reference level (DRL) system. This entails calculating a DRL value for each possible image technique/view considered to perform a diagnostic mammogram in our practice. Diagnostic mammographies from a total of 1191 patients who underwent a diagnostic mammogram study in our designated diagnostic mammography center were collected and retrospectively analyzed. The DRL representing our health sector was set as the median of the mean glandular dose (MGD) for each possible image technique/view, including the 2D standard bilateral craniocaudal (LCC/RCC) and mediolateral oblique (LMLO/RMLO), the 2D bilateral spot compression CC and MLO (RSCC/LSCC and RSMLO/LSMLO), the 2D bilateral spot compression with magnification (RMSCC/LMSCC and RMSMLO/LMSMLO), the 3D digital breast tomosynthesis CC and MLO (RCC/LCC and RMLO/LMLO), the 2D bilateral implant CC and MLO (RIMCC/LIMCC and RIMMLO/LIMMLO), the 2D bilateral contrast enhanced CC and MLO (RCECC/LCECC and RCEMLO/LCEMLO) and the 2D bilateral stereotactic biopsy guided CC (SBRCC/SBLCC). This patient dose review revealed that the highest MGD was associated with the 2D bilateral spot compression with magnification (MSCC/MSMLO) image view. For the compressed breast thickness (CBT) group 60-69 mm, the median and 75th percentile of the MGD values obtained were MSCC: 3.35 and 3.96, MSMLO: 4.14 and 5.25 mGy respectively. Obvious MGD variations were witnessed across the different possible views even for the same CBT group. Our results are in line with the published DRLs when using same statistical quantity and CBT group.</p>","PeriodicalId":37035,"journal":{"name":"Journal of Imaging","volume":"11 3","pages":""},"PeriodicalIF":2.7000,"publicationDate":"2025-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11943081/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/jimaging11030079","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"IMAGING SCIENCE & PHOTOGRAPHIC TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

The aim of this patient dose review is to establish a thorough diagnostic reference level (DRL) system. This entails calculating a DRL value for each possible image technique/view considered to perform a diagnostic mammogram in our practice. Diagnostic mammographies from a total of 1191 patients who underwent a diagnostic mammogram study in our designated diagnostic mammography center were collected and retrospectively analyzed. The DRL representing our health sector was set as the median of the mean glandular dose (MGD) for each possible image technique/view, including the 2D standard bilateral craniocaudal (LCC/RCC) and mediolateral oblique (LMLO/RMLO), the 2D bilateral spot compression CC and MLO (RSCC/LSCC and RSMLO/LSMLO), the 2D bilateral spot compression with magnification (RMSCC/LMSCC and RMSMLO/LMSMLO), the 3D digital breast tomosynthesis CC and MLO (RCC/LCC and RMLO/LMLO), the 2D bilateral implant CC and MLO (RIMCC/LIMCC and RIMMLO/LIMMLO), the 2D bilateral contrast enhanced CC and MLO (RCECC/LCECC and RCEMLO/LCEMLO) and the 2D bilateral stereotactic biopsy guided CC (SBRCC/SBLCC). This patient dose review revealed that the highest MGD was associated with the 2D bilateral spot compression with magnification (MSCC/MSMLO) image view. For the compressed breast thickness (CBT) group 60-69 mm, the median and 75th percentile of the MGD values obtained were MSCC: 3.35 and 3.96, MSMLO: 4.14 and 5.25 mGy respectively. Obvious MGD variations were witnessed across the different possible views even for the same CBT group. Our results are in line with the published DRLs when using same statistical quantity and CBT group.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Imaging
Journal of Imaging Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
5.90
自引率
6.20%
发文量
303
审稿时长
7 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信