Comparison of three blood collection tubes for 16 biochemical analytes and stability assessment of selected analytes: VACUETTE® CAT serum Sep clot activator tube, VACUETTE® LH lithium heparin Sep tube, and VACUETTE® CAT serum fast separator tube.

IF 2.1 4区 医学 Q3 MEDICAL LABORATORY TECHNOLOGY
Jong Do Seo, Yeon Jae Lee, Changhee Ha, Ju Hee Choi, Seon-Hyeon Shin, Hye Young Han, Hyun-Joong Kim, Sung Hea Kim, Bum Sung Kim, Hanah Kim, Hee-Won Moon, Mina Hur, Yeo-Min Yun
{"title":"Comparison of three blood collection tubes for 16 biochemical analytes and stability assessment of selected analytes: VACUETTE<sup>®</sup> CAT serum Sep clot activator tube, VACUETTE<sup>®</sup> LH lithium heparin Sep tube, and VACUETTE<sup>®</sup> CAT serum fast separator tube.","authors":"Jong Do Seo, Yeon Jae Lee, Changhee Ha, Ju Hee Choi, Seon-Hyeon Shin, Hye Young Han, Hyun-Joong Kim, Sung Hea Kim, Bum Sung Kim, Hanah Kim, Hee-Won Moon, Mina Hur, Yeo-Min Yun","doi":"10.1177/00045632251329272","DOIUrl":null,"url":null,"abstract":"<p><p>BackgroundAnalytical performance of VACUETTE® CAT Serum Fast Separator Tube (SFT; Greiner Bio-One, Austria), recently developed quick-clotting serum separator, was evaluated for correlation and stability, comparing with VACUETTE® CAT Serum Sep Clot Activator Tube (SST; Greiner Bio-One) and VACUETTE® LH Lithium Heparin Sep Tube (LiHep Tube; Greiner Bio-One).MethodFor 107 paired samples, 16 analytes (glucose, potassium, LDH, CRP, creatinine, AST, ALT, ALP, GGT, AFP, PSA, TSH, free T4, iPTH, CK-MB, and cardiac troponin I[cTnI]) were measured. Correlations were assessed using Passing-Bablok regression and paired t-tests. Differences were evaluated by comparing the mean percentage difference and estimated difference at medical decision limits (MDLs), to the acceptable desirable difference. For six analytes - glucose, potassium, LDH, AST, iPTH, and cTnI - known for different stabilities between sample types, stability was evaluated by comparing changes over time with desirable differences.ResultsAcross the evaluated range, SFT showed clinically comparable differences to SST, except for CK-MB which showed significant positive bias. Plasma exhibited unacceptable biases: negative for potassium and positive for LDH and CK-MB. Estimated differences at MDLs were acceptable in SFT except for potassium and CK-MB, while plasma showed unacceptable differences in potassium, LDH, creatinine, and CK-MB. LiHep Tube showed reduced stability than SST for all analytes except for iPTH, impairing retest reliability. SFT showed comparable stability except for LDH and iPTH, which showed slightly shortened stability.ConclusionsThe SFT demonstrated high correlation and comparable stability to SST, making it a suitable replacement for the LiHep Tube, as an alternative to SST for rapid testing.</p>","PeriodicalId":8005,"journal":{"name":"Annals of Clinical Biochemistry","volume":" ","pages":"45632251329272"},"PeriodicalIF":2.1000,"publicationDate":"2025-03-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Clinical Biochemistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/00045632251329272","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

BackgroundAnalytical performance of VACUETTE® CAT Serum Fast Separator Tube (SFT; Greiner Bio-One, Austria), recently developed quick-clotting serum separator, was evaluated for correlation and stability, comparing with VACUETTE® CAT Serum Sep Clot Activator Tube (SST; Greiner Bio-One) and VACUETTE® LH Lithium Heparin Sep Tube (LiHep Tube; Greiner Bio-One).MethodFor 107 paired samples, 16 analytes (glucose, potassium, LDH, CRP, creatinine, AST, ALT, ALP, GGT, AFP, PSA, TSH, free T4, iPTH, CK-MB, and cardiac troponin I[cTnI]) were measured. Correlations were assessed using Passing-Bablok regression and paired t-tests. Differences were evaluated by comparing the mean percentage difference and estimated difference at medical decision limits (MDLs), to the acceptable desirable difference. For six analytes - glucose, potassium, LDH, AST, iPTH, and cTnI - known for different stabilities between sample types, stability was evaluated by comparing changes over time with desirable differences.ResultsAcross the evaluated range, SFT showed clinically comparable differences to SST, except for CK-MB which showed significant positive bias. Plasma exhibited unacceptable biases: negative for potassium and positive for LDH and CK-MB. Estimated differences at MDLs were acceptable in SFT except for potassium and CK-MB, while plasma showed unacceptable differences in potassium, LDH, creatinine, and CK-MB. LiHep Tube showed reduced stability than SST for all analytes except for iPTH, impairing retest reliability. SFT showed comparable stability except for LDH and iPTH, which showed slightly shortened stability.ConclusionsThe SFT demonstrated high correlation and comparable stability to SST, making it a suitable replacement for the LiHep Tube, as an alternative to SST for rapid testing.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Annals of Clinical Biochemistry
Annals of Clinical Biochemistry Biochemistry, Genetics and Molecular Biology-Clinical Biochemistry
CiteScore
5.20
自引率
4.50%
发文量
61
期刊介绍: Annals of Clinical Biochemistry is the fully peer reviewed international journal of the Association for Clinical Biochemistry and Laboratory Medicine. Annals of Clinical Biochemistry accepts papers that contribute to knowledge in all fields of laboratory medicine, especially those pertaining to the understanding, diagnosis and treatment of human disease. It publishes papers on clinical biochemistry, clinical audit, metabolic medicine, immunology, genetics, biotechnology, haematology, microbiology, computing and management where they have both biochemical and clinical relevance. Papers describing evaluation or implementation of commercial reagent kits or the performance of new analysers require substantial original information. Unless of exceptional interest and novelty, studies dealing with the redox status in various diseases are not generally considered within the journal''s scope. Studies documenting the association of single nucleotide polymorphisms (SNPs) with particular phenotypes will not normally be considered, given the greater strength of genome wide association studies (GWAS). Research undertaken in non-human animals will not be considered for publication in the Annals. Annals of Clinical Biochemistry is also the official journal of NVKC (de Nederlandse Vereniging voor Klinische Chemie) and JSCC (Japan Society of Clinical Chemistry).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信