{"title":"Haemodynamic monitoring and management during non-cardiac surgery: a survey among German anaesthesiologists.","authors":"Benjamin Vojnar, Patrick Achenbach, Moritz Flick, Daniel Reuter, Michael Sander, Bernd Saugel, Ann-Kristin Schubert, Christine Gaik","doi":"10.1007/s10877-025-01284-0","DOIUrl":null,"url":null,"abstract":"<p><p>In 2023, the first German guideline on intraoperative haemodynamic monitoring and management for adults having non-cardiac surgery was published. The aim of this survey was to identify how anaesthetists in Germany managed intraoperative haemodynamics and blood pressure before its publication. In September to October 2023, members of the German Society of Anaesthesiology and Intensive Care Medicine (DGAI) were invited via email to participate in this anonymous online survey. Thirty-one questions covered demographics, clinical experience, approaches to perioperative blood pressure measurement and common thresholds, as well as the use of advanced haemodynamic monitoring and its potential therapeutic implications. 1,079 fully completed questionnaires were included in the analysis. When intermittent oscillometry was used to measure blood pressure, a 3-minute interval was usually applied during induction of anaesthesia (42%; 451/1,079). For invasive blood pressure monitoring, more than half (53%; 574/1,079) inserted an arterial line after induction of anaesthesia. Nearly all (94%; 1,012/1,079) focused on the mean arterial pressure for blood pressure monitoring, with a large majority (77%; 779/1012) considering values below 60-65 mmHg to be critically low. Intraoperative hypotension was managed based on an internal protocol by only 21% (223/1,079). Regarding advanced haemodynamic monitoring, 43% (459/1,079) frequently used pulse contour analysis, while 67% (721/1,079) reported that monitors with finger-cuff technology were not available in their department. 47% (504/1,079) cited a lack of experience as one of the main reasons for the infrequent use of cardiac output monitoring. This survey among DGAI members provides important insights into current practices of haemodynamic monitoring and management prior to the publication of the recent German guideline on 'Intraoperative haemodynamic monitoring and management of adults having non-cardiac surgery'.</p>","PeriodicalId":15513,"journal":{"name":"Journal of Clinical Monitoring and Computing","volume":" ","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2025-03-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Monitoring and Computing","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10877-025-01284-0","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
In 2023, the first German guideline on intraoperative haemodynamic monitoring and management for adults having non-cardiac surgery was published. The aim of this survey was to identify how anaesthetists in Germany managed intraoperative haemodynamics and blood pressure before its publication. In September to October 2023, members of the German Society of Anaesthesiology and Intensive Care Medicine (DGAI) were invited via email to participate in this anonymous online survey. Thirty-one questions covered demographics, clinical experience, approaches to perioperative blood pressure measurement and common thresholds, as well as the use of advanced haemodynamic monitoring and its potential therapeutic implications. 1,079 fully completed questionnaires were included in the analysis. When intermittent oscillometry was used to measure blood pressure, a 3-minute interval was usually applied during induction of anaesthesia (42%; 451/1,079). For invasive blood pressure monitoring, more than half (53%; 574/1,079) inserted an arterial line after induction of anaesthesia. Nearly all (94%; 1,012/1,079) focused on the mean arterial pressure for blood pressure monitoring, with a large majority (77%; 779/1012) considering values below 60-65 mmHg to be critically low. Intraoperative hypotension was managed based on an internal protocol by only 21% (223/1,079). Regarding advanced haemodynamic monitoring, 43% (459/1,079) frequently used pulse contour analysis, while 67% (721/1,079) reported that monitors with finger-cuff technology were not available in their department. 47% (504/1,079) cited a lack of experience as one of the main reasons for the infrequent use of cardiac output monitoring. This survey among DGAI members provides important insights into current practices of haemodynamic monitoring and management prior to the publication of the recent German guideline on 'Intraoperative haemodynamic monitoring and management of adults having non-cardiac surgery'.
期刊介绍:
The Journal of Clinical Monitoring and Computing is a clinical journal publishing papers related to technology in the fields of anaesthesia, intensive care medicine, emergency medicine, and peri-operative medicine.
The journal has links with numerous specialist societies, including editorial board representatives from the European Society for Computing and Technology in Anaesthesia and Intensive Care (ESCTAIC), the Society for Technology in Anesthesia (STA), the Society for Complex Acute Illness (SCAI) and the NAVAt (NAVigating towards your Anaestheisa Targets) group.
The journal publishes original papers, narrative and systematic reviews, technological notes, letters to the editor, editorial or commentary papers, and policy statements or guidelines from national or international societies. The journal encourages debate on published papers and technology, including letters commenting on previous publications or technological concerns. The journal occasionally publishes special issues with technological or clinical themes, or reports and abstracts from scientificmeetings. Special issues proposals should be sent to the Editor-in-Chief. Specific details of types of papers, and the clinical and technological content of papers considered within scope can be found in instructions for authors.