{"title":"Preliminary study on the feasibility of united compressed sensing with radial acquisition as a routine method for liver dynamic contrast-enhanced examination in elderly patients with malignancy.","authors":"Heping Deng, Xiaolei Dong, Yu Zhang, Peng Zhou, Yakun He, Liu Yang","doi":"10.1186/s13244-025-01936-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To explore the value of the united imaging compressed sensing with radial acquisition (uCSR) in liver dynamic contrast-enhanced examinations for elderly patients with malignancy.</p><p><strong>Methods: </strong>Hundred patients aged 65 years or over were randomly divided into two groups: 50 patients underwent liver dynamic contrast-enhanced scanning using the uCSR sequence during free breathing, and 50 patients underwent scanning using the three-dimensional volume interpolated breath-hold examination (3D-VIBE) sequence while holding breath. Two radiologists independently and subjectively evaluated the overall image quality and image artifacts with a five-point scale. Concurrently, two technologists measured the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the arterial, portal venous and delay phase images in both groups.</p><p><strong>Results: </strong>uCSR has superior overall image-quality and image-artifact scores (z = 2.342, p = 0.019; z = 2.105, p = 0.035). The 3D-VIBE images of the arterial phase have higher SNR than uCSR (t = 4.988, p = 0.000), with no significant difference in the CNR (z = 0.676, p = 0.499). In the portal venous phase, the SNR and CNR of the 3D-VIBE images are superior to those of uCSR (z = 5.674, p = 0.000; t = 3.638, p = 0.000). In the delay phase, the SNR of the 3D-VIBE is slightly better than the uCSR (t = 5.471, p = 0.000), and the CNR shows no significant difference (z = 1.258, p = 0.208).</p><p><strong>Conclusion: </strong>uCSR can be used as a method for liver dynamic contrast-enhanced scans in elderly patients with malignancy. It can improve patient comfort and reduce the failure rate of scans.</p><p><strong>Critical relevance statement: </strong>Our findings suggested that uCSR can be used for liver dynamic contrast-enhanced scans in elderly patients with malignancy, this preliminary study provided basis for it.</p><p><strong>Key points: </strong>The uCSR can suppress the impact of respiratory motion artifacts on images. The UCSR can perform dynamic enhanced scanning of the liver under free breathing dynamics. The uCSR is suitable for dynamic contrast-enhanced MR imaging of the liver in elderly patients with malignancy.</p>","PeriodicalId":13639,"journal":{"name":"Insights into Imaging","volume":"16 1","pages":"65"},"PeriodicalIF":4.1000,"publicationDate":"2025-03-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11929642/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Insights into Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s13244-025-01936-4","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: To explore the value of the united imaging compressed sensing with radial acquisition (uCSR) in liver dynamic contrast-enhanced examinations for elderly patients with malignancy.
Methods: Hundred patients aged 65 years or over were randomly divided into two groups: 50 patients underwent liver dynamic contrast-enhanced scanning using the uCSR sequence during free breathing, and 50 patients underwent scanning using the three-dimensional volume interpolated breath-hold examination (3D-VIBE) sequence while holding breath. Two radiologists independently and subjectively evaluated the overall image quality and image artifacts with a five-point scale. Concurrently, two technologists measured the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the arterial, portal venous and delay phase images in both groups.
Results: uCSR has superior overall image-quality and image-artifact scores (z = 2.342, p = 0.019; z = 2.105, p = 0.035). The 3D-VIBE images of the arterial phase have higher SNR than uCSR (t = 4.988, p = 0.000), with no significant difference in the CNR (z = 0.676, p = 0.499). In the portal venous phase, the SNR and CNR of the 3D-VIBE images are superior to those of uCSR (z = 5.674, p = 0.000; t = 3.638, p = 0.000). In the delay phase, the SNR of the 3D-VIBE is slightly better than the uCSR (t = 5.471, p = 0.000), and the CNR shows no significant difference (z = 1.258, p = 0.208).
Conclusion: uCSR can be used as a method for liver dynamic contrast-enhanced scans in elderly patients with malignancy. It can improve patient comfort and reduce the failure rate of scans.
Critical relevance statement: Our findings suggested that uCSR can be used for liver dynamic contrast-enhanced scans in elderly patients with malignancy, this preliminary study provided basis for it.
Key points: The uCSR can suppress the impact of respiratory motion artifacts on images. The UCSR can perform dynamic enhanced scanning of the liver under free breathing dynamics. The uCSR is suitable for dynamic contrast-enhanced MR imaging of the liver in elderly patients with malignancy.
目的:探讨联合成像压缩感知与径向采集(uCSR)在老年恶性肿瘤患者肝脏动态增强检查中的应用价值。方法:将100例65岁及以上的患者随机分为两组:50例患者在自由呼吸时使用uCSR序列进行肝脏动态对比增强扫描,50例患者在屏气时使用三维体积内插屏气检查(3D-VIBE)序列进行扫描。两名放射科医生独立和主观地用五分制评估整体图像质量和图像伪影。同时,两名技术人员测量了两组动脉、门静脉和延迟期图像的信噪比(SNR)和噪声对比比(CNR)。结果:uCSR具有较好的整体图像质量和图像伪影评分(z = 2.342, p = 0.019;Z = 2.105, p = 0.035)。动脉期3D-VIBE图像的信噪比高于uCSR (t = 4.988, p = 0.000),而CNR差异无统计学意义(z = 0.676, p = 0.499)。门静脉期,3D-VIBE图像的信噪比和CNR优于uCSR (z = 5.674, p = 0.000;T = 3.638, p = 0.000)。在延迟阶段,3D-VIBE的信噪比略好于uCSR (t = 5.471, p = 0.000),而CNR无显著差异(z = 1.258, p = 0.208)。结论:uCSR可作为老年恶性肿瘤患者肝脏动态增强扫描的一种方法。提高患者舒适度,降低扫描失败率。关键相关性声明:我们的研究结果提示uCSR可用于老年恶性肿瘤患者的肝脏动态对比增强扫描,本初步研究为其提供了依据。重点:uCSR可以抑制呼吸运动伪影对图像的影响。UCSR可以在自由呼吸动力下对肝脏进行动态增强扫描。uCSR适用于老年恶性肿瘤患者肝脏动态增强磁共振成像。
期刊介绍:
Insights into Imaging (I³) is a peer-reviewed open access journal published under the brand SpringerOpen. All content published in the journal is freely available online to anyone, anywhere!
I³ continuously updates scientific knowledge and progress in best-practice standards in radiology through the publication of original articles and state-of-the-art reviews and opinions, along with recommendations and statements from the leading radiological societies in Europe.
Founded by the European Society of Radiology (ESR), I³ creates a platform for educational material, guidelines and recommendations, and a forum for topics of controversy.
A balanced combination of review articles, original papers, short communications from European radiological congresses and information on society matters makes I³ an indispensable source for current information in this field.
I³ is owned by the ESR, however authors retain copyright to their article according to the Creative Commons Attribution License (see Copyright and License Agreement). All articles can be read, redistributed and reused for free, as long as the author of the original work is cited properly.
The open access fees (article-processing charges) for this journal are kindly sponsored by ESR for all Members.
The journal went open access in 2012, which means that all articles published since then are freely available online.