Transitioning from concept to application: Comprehensive analytical validation of antibody-based smart sampling

IF 3.1 3区 医学 Q2 CHEMISTRY, ANALYTICAL
Ago Mrsa , Ridja Ishaq, Laila Brandoli, Trine Grønhaug Halvorsen , Léon Reubsaet
{"title":"Transitioning from concept to application: Comprehensive analytical validation of antibody-based smart sampling","authors":"Ago Mrsa ,&nbsp;Ridja Ishaq,&nbsp;Laila Brandoli,&nbsp;Trine Grønhaug Halvorsen ,&nbsp;Léon Reubsaet","doi":"10.1016/j.jpba.2025.116825","DOIUrl":null,"url":null,"abstract":"<div><div>Smart sampling, introduced in 2018, is a technique that integrates crucial sample preparation steps for LC-MS protein analysis directly into the sampling process, improving efficiency. Currently most studies in this area are limited to proof of concept with a brief evaluation. Therefore, our objective is to fully validate the utility of smart samplers for quantitative analysis of bioactive proteins in biological matrices. This study builds on previous work where a paper-based antibody sampler was developed, and human chorionic gonadotropin (hCG) was used as a model protein. hCG is both a biomarker, a drug, and on the doping list for male athletes. Initially, the fabrication of the sampler was optimized, resulting in a reduction of antibody amount per sampler from 50 µg to 5 µg, reducing manufacturing cost while maintaining acceptable performance. It was also shown that removing the sampler before trypsination, but after reduction and alkylation greatly improved signal output while reducing the peptide background, suggesting a cleanser extract was achieved. The optimized smart sampler was validated for hCG in human serum using EMA’s ICH M10 guidelines on bioanalytical methods as a guide. Three calibration curves (seven levels) were made in the concentration range of 0.5 ng/mL to 75 ng/mL all displaying excellent linearity (r<sup>2</sup> ≥ 0.9955). The accuracy and precision both for the between-run (precision ≤ 10 % CV and accuracy 91–105 % (n = 3)) and within-run (precision ≤ 14 % CV and accuracy 94–105 % (n = 5)) runs were all well within the guideline's acceptance limits. The samplers also showed to be stable for at least ten weeks at room temperature. The optimization and validation of the antibody sampler detailed in this paper marks a notable progression, advancing the concept of \"smart sampling\" a step closer from the lab to practical application.</div></div>","PeriodicalId":16685,"journal":{"name":"Journal of pharmaceutical and biomedical analysis","volume":"260 ","pages":"Article 116825"},"PeriodicalIF":3.1000,"publicationDate":"2025-03-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of pharmaceutical and biomedical analysis","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0731708525001669","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Smart sampling, introduced in 2018, is a technique that integrates crucial sample preparation steps for LC-MS protein analysis directly into the sampling process, improving efficiency. Currently most studies in this area are limited to proof of concept with a brief evaluation. Therefore, our objective is to fully validate the utility of smart samplers for quantitative analysis of bioactive proteins in biological matrices. This study builds on previous work where a paper-based antibody sampler was developed, and human chorionic gonadotropin (hCG) was used as a model protein. hCG is both a biomarker, a drug, and on the doping list for male athletes. Initially, the fabrication of the sampler was optimized, resulting in a reduction of antibody amount per sampler from 50 µg to 5 µg, reducing manufacturing cost while maintaining acceptable performance. It was also shown that removing the sampler before trypsination, but after reduction and alkylation greatly improved signal output while reducing the peptide background, suggesting a cleanser extract was achieved. The optimized smart sampler was validated for hCG in human serum using EMA’s ICH M10 guidelines on bioanalytical methods as a guide. Three calibration curves (seven levels) were made in the concentration range of 0.5 ng/mL to 75 ng/mL all displaying excellent linearity (r2 ≥ 0.9955). The accuracy and precision both for the between-run (precision ≤ 10 % CV and accuracy 91–105 % (n = 3)) and within-run (precision ≤ 14 % CV and accuracy 94–105 % (n = 5)) runs were all well within the guideline's acceptance limits. The samplers also showed to be stable for at least ten weeks at room temperature. The optimization and validation of the antibody sampler detailed in this paper marks a notable progression, advancing the concept of "smart sampling" a step closer from the lab to practical application.
从概念到应用的过渡:基于抗体的智能采样的全面分析验证
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.70
自引率
5.90%
发文量
588
审稿时长
37 days
期刊介绍: This journal is an international medium directed towards the needs of academic, clinical, government and industrial analysis by publishing original research reports and critical reviews on pharmaceutical and biomedical analysis. It covers the interdisciplinary aspects of analysis in the pharmaceutical, biomedical and clinical sciences, including developments in analytical methodology, instrumentation, computation and interpretation. Submissions on novel applications focusing on drug purity and stability studies, pharmacokinetics, therapeutic monitoring, metabolic profiling; drug-related aspects of analytical biochemistry and forensic toxicology; quality assurance in the pharmaceutical industry are also welcome. Studies from areas of well established and poorly selective methods, such as UV-VIS spectrophotometry (including derivative and multi-wavelength measurements), basic electroanalytical (potentiometric, polarographic and voltammetric) methods, fluorimetry, flow-injection analysis, etc. are accepted for publication in exceptional cases only, if a unique and substantial advantage over presently known systems is demonstrated. The same applies to the assay of simple drug formulations by any kind of methods and the determination of drugs in biological samples based merely on spiked samples. Drug purity/stability studies should contain information on the structure elucidation of the impurities/degradants.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信