{"title":"Evaluation of early implant failure in Japanese patients undergoing unrestricted kinematic alignment total knee arthroplasty","authors":"Shuji Toyono ,&nbsp;Shigenobu Fukushima ,&nbsp;Takao Yamamoto ,&nbsp;Takashi Ito ,&nbsp;Takahiro Miyaji ,&nbsp;Akemi Suzuki ,&nbsp;Michiaki Takagi","doi":"10.1016/j.jjoisr.2025.02.004","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><div>Total knee arthroplasty (TKA) traditionally involves mechanical alignment with a target range of ±3°. However, unrestricted kinematic alignment (urKA) has emerged as a viable alternative, potentially maintaining a favorable implant survival rate without the constraints of neutral alignment. Japanese people have more pronounced tibial varus than other populations. This study evaluated early implant failures in Japanese patients with osteoarthritis who underwent urKA-TKA.</div></div><div><h3>Methods</h3><div>In this study, 557 knees of 460 patients who underwent urKA-TKA between June 2019 and September 2021 were retrospectively analyzed. Surgeries were conducted by four surgeons using standardized urKA techniques, ensuring consistent ligament balancing and component positioning. The primary outcome was the rate of revision for aseptic loosening over at least 2 years, with secondary outcomes focusing on post-operative alignment.</div></div><div><h3>Results</h3><div>The follow-up rate was 95%, with a mean of 3.0 years. The implant survival rate was 100% considering implant revision as the endpoint, and 99% when re-operation was included. Post-operative alignment revealed that 60.3% of tibial components and 39.3% of limbs had varus alignment exceeding 3°; however, this did not compromise implant survival during the follow-up period.</div></div><div><h3>Conclusions</h3><div>The follow-up of at least 2 years for urKA-TKA in a Japanese cohort demonstrated no early implant failures with no significant effect on outcomes from deviations in varus alignment. These results support the use of urKA-TKA and underscore the need for long-term studies to further substantiate these findings in the Japanese population.</div></div>","PeriodicalId":100795,"journal":{"name":"Journal of Joint Surgery and Research","volume":"3 2","pages":"Pages 79-83"},"PeriodicalIF":0.0000,"publicationDate":"2025-03-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Joint Surgery and Research","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2949705125000076","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose

Total knee arthroplasty (TKA) traditionally involves mechanical alignment with a target range of ±3°. However, unrestricted kinematic alignment (urKA) has emerged as a viable alternative, potentially maintaining a favorable implant survival rate without the constraints of neutral alignment. Japanese people have more pronounced tibial varus than other populations. This study evaluated early implant failures in Japanese patients with osteoarthritis who underwent urKA-TKA.

Methods

In this study, 557 knees of 460 patients who underwent urKA-TKA between June 2019 and September 2021 were retrospectively analyzed. Surgeries were conducted by four surgeons using standardized urKA techniques, ensuring consistent ligament balancing and component positioning. The primary outcome was the rate of revision for aseptic loosening over at least 2 years, with secondary outcomes focusing on post-operative alignment.

Results

The follow-up rate was 95%, with a mean of 3.0 years. The implant survival rate was 100% considering implant revision as the endpoint, and 99% when re-operation was included. Post-operative alignment revealed that 60.3% of tibial components and 39.3% of limbs had varus alignment exceeding 3°; however, this did not compromise implant survival during the follow-up period.

Conclusions

The follow-up of at least 2 years for urKA-TKA in a Japanese cohort demonstrated no early implant failures with no significant effect on outcomes from deviations in varus alignment. These results support the use of urKA-TKA and underscore the need for long-term studies to further substantiate these findings in the Japanese population.
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信