{"title":"Efficiency Improvement of the Clinical Pathway in Cardiac Monitor Insertion and Follow-Up: Retrospective Analysis.","authors":"Ville Vanhala, Outi Surakka, Vilma Multisilta, Mette Lundsby Johansen, Jonas Villinger, Emmanuelle Nicolle, Johanna Heikkilä, Pentti Korhonen","doi":"10.2196/67774","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The insertable cardiac monitor (ICM) clinical pathway in Tampere Heart Hospital, Finland, did not correspond to the diagnostic needs of the population. There has been growing evidence of delegating the insertion from cardiologists to specially trained nurses and outsourcing the remote follow-up. However, it is unclear if the change in the clinical pathway is safe and improves efficiency.</p><p><strong>Objective: </strong>We aim to describe and assess the efficiency of the change in the ICM clinical pathway.</p><p><strong>Methods: </strong>Pathway improvements included initiating nurse-performed insertions, relocating the procedure from the catheterization laboratory to a procedure room, and outsourcing part of the remote follow-up to manage ICM workload. Data were collected from electronic health records of all patients who received an ICM in the Tampere Heart Hospital in 2018 and 2020. Follow-up time was 36 months after insertion.</p><p><strong>Results: </strong>The number of inserted ICMs doubled from 74 in 2018 to 159 in 2020. In 2018, cardiologists completed all insertions, while in 2020, a total of 70.4% (n=112) were completed by nurses. The waiting time from referral to procedure was significantly shorter in 2020 (mean 36, SD 27.7 days) compared with 2018 (mean 49, SD 37.3 days; P=.02). The scheduled ICM procedure time decreased from 60 minutes in 2018 to 45 minutes in 2020. Insertions performed in the catheterization laboratory decreased significantly (n=14, 18.9% in 2018 and n=3, 1.9% in 2020; P=<.001). Patients receiving an ICM after syncope increased from 71 to 94 patients. Stroke and transient ischemic attack as an indication increased substantially from 2018 to 2020 (2 and 62 patients, respectively). In 2018, nurses analyzed all remote transmissions. In 2020, the external monitoring service escalated only 11.2% (204/1817) of the transmissions to the clinic for revision. This saved 296 hours of nursing time in 2020. Having nurses insert ICMs in 2020 saved 48 hours of physicians' time and the shorter scheduling for the procedure saved an additional 40 hours of nursing time compared with the process in 2018. Additionally, the catheterization laboratory was released for other procedures (27 h/y). The complication rate did not change significantly (n=2, 2.7% in 2018 and n=5, 3.1% in 2020; P=.85). The 36-month diagnostic yield for syncope remained high in 2018 and 2020 (n=32, 45.1% and n=36, 38.3%; P=.38). The diagnostic yield for patients who had stroke with a procedure in 2020 was 43.5% (n=27).</p><p><strong>Conclusions: </strong>The efficiency of the clinical pathway for patients eligible for an ICM insertation can be increased significantly by shifting to nurse-led insertions in procedure rooms and to the use of an external monitoring and triaging service.</p>","PeriodicalId":14706,"journal":{"name":"JMIR Cardio","volume":"9 ","pages":"e67774"},"PeriodicalIF":0.0000,"publicationDate":"2025-03-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11951822/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JMIR Cardio","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2196/67774","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The insertable cardiac monitor (ICM) clinical pathway in Tampere Heart Hospital, Finland, did not correspond to the diagnostic needs of the population. There has been growing evidence of delegating the insertion from cardiologists to specially trained nurses and outsourcing the remote follow-up. However, it is unclear if the change in the clinical pathway is safe and improves efficiency.

Objective: We aim to describe and assess the efficiency of the change in the ICM clinical pathway.

Methods: Pathway improvements included initiating nurse-performed insertions, relocating the procedure from the catheterization laboratory to a procedure room, and outsourcing part of the remote follow-up to manage ICM workload. Data were collected from electronic health records of all patients who received an ICM in the Tampere Heart Hospital in 2018 and 2020. Follow-up time was 36 months after insertion.

Results: The number of inserted ICMs doubled from 74 in 2018 to 159 in 2020. In 2018, cardiologists completed all insertions, while in 2020, a total of 70.4% (n=112) were completed by nurses. The waiting time from referral to procedure was significantly shorter in 2020 (mean 36, SD 27.7 days) compared with 2018 (mean 49, SD 37.3 days; P=.02). The scheduled ICM procedure time decreased from 60 minutes in 2018 to 45 minutes in 2020. Insertions performed in the catheterization laboratory decreased significantly (n=14, 18.9% in 2018 and n=3, 1.9% in 2020; P=<.001). Patients receiving an ICM after syncope increased from 71 to 94 patients. Stroke and transient ischemic attack as an indication increased substantially from 2018 to 2020 (2 and 62 patients, respectively). In 2018, nurses analyzed all remote transmissions. In 2020, the external monitoring service escalated only 11.2% (204/1817) of the transmissions to the clinic for revision. This saved 296 hours of nursing time in 2020. Having nurses insert ICMs in 2020 saved 48 hours of physicians' time and the shorter scheduling for the procedure saved an additional 40 hours of nursing time compared with the process in 2018. Additionally, the catheterization laboratory was released for other procedures (27 h/y). The complication rate did not change significantly (n=2, 2.7% in 2018 and n=5, 3.1% in 2020; P=.85). The 36-month diagnostic yield for syncope remained high in 2018 and 2020 (n=32, 45.1% and n=36, 38.3%; P=.38). The diagnostic yield for patients who had stroke with a procedure in 2020 was 43.5% (n=27).

Conclusions: The efficiency of the clinical pathway for patients eligible for an ICM insertation can be increased significantly by shifting to nurse-led insertions in procedure rooms and to the use of an external monitoring and triaging service.

求助全文
约1分钟内获得全文 求助全文
来源期刊
JMIR Cardio
JMIR Cardio Computer Science-Computer Science Applications
CiteScore
3.50
自引率
0.00%
发文量
25
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信