Tailoring antiseizure treatment with a wearable device: A proof-of-concept study in absence epilepsy.

IF 6.6 1区 医学 Q1 CLINICAL NEUROLOGY
Epilepsia Pub Date : 2025-03-21 DOI:10.1111/epi.18384
Jaiver Macea, Christos Chatzichristos, Miguel Bhagubai, Maarten De Vos, Wim Van Paesschen
{"title":"Tailoring antiseizure treatment with a wearable device: A proof-of-concept study in absence epilepsy.","authors":"Jaiver Macea, Christos Chatzichristos, Miguel Bhagubai, Maarten De Vos, Wim Van Paesschen","doi":"10.1111/epi.18384","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Typical absence seizures are underreported. We aimed to improve patient care using a wearable electroencephalograph (wEEG) at home and assess a machine learning (ML) pipeline for absence detection.</p><p><strong>Methods: </strong>Patients with typical absences used a wEEG device 12-24 h 1 week after antiseizure medication (ASM) adjustments. Three-hertz generalized spike-wave discharges (SWDs) ≥ 3 s were used as absence surrogates. After manual inspection, we used the results to guide medical treatment. The outcomes were seizure freedom, number of consecutive measurements without relapse, and side effects. Afterward, we used the ML pipeline on the recordings, and a neurologist reviewed the output. Review time and diagnostic performance were compared with manual inspection.</p><p><strong>Results: </strong>Nineteen patients (12 female, median age = 24 years) were followed for a median of 5 months (range = 1-12). The median recording time for each session was 21.3 h (range = 10-24). Fifteen patients (79%) were seizure-free during the last measurement, including seven of 11 (63%) diagnosed with refractory epilepsy. Ten patients relapsed after a median of 1-2 recordings (range = 1-6) without 3-Hz SWDs. Side effects occurred in 21% of patients. Manual file inspection identified 806 3-Hz SWDs of ≥3 s. The ML pipeline reduced a neurologist's median review time for 24-h wEEG from 27 (range = 10-45) to 4.3 min (range = .1-10), with a sensitivity, precision, F1-score, and false positives per hour of .8, .95, .87, and .007, respectively.</p><p><strong>Significance: </strong>Home-based wEEG allows patient monitoring after ASM adjustments, improving absence seizure management. The ML-based pipeline performed well and was crucial in reducing review time.</p>","PeriodicalId":11768,"journal":{"name":"Epilepsia","volume":" ","pages":""},"PeriodicalIF":6.6000,"publicationDate":"2025-03-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Epilepsia","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/epi.18384","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: Typical absence seizures are underreported. We aimed to improve patient care using a wearable electroencephalograph (wEEG) at home and assess a machine learning (ML) pipeline for absence detection.

Methods: Patients with typical absences used a wEEG device 12-24 h 1 week after antiseizure medication (ASM) adjustments. Three-hertz generalized spike-wave discharges (SWDs) ≥ 3 s were used as absence surrogates. After manual inspection, we used the results to guide medical treatment. The outcomes were seizure freedom, number of consecutive measurements without relapse, and side effects. Afterward, we used the ML pipeline on the recordings, and a neurologist reviewed the output. Review time and diagnostic performance were compared with manual inspection.

Results: Nineteen patients (12 female, median age = 24 years) were followed for a median of 5 months (range = 1-12). The median recording time for each session was 21.3 h (range = 10-24). Fifteen patients (79%) were seizure-free during the last measurement, including seven of 11 (63%) diagnosed with refractory epilepsy. Ten patients relapsed after a median of 1-2 recordings (range = 1-6) without 3-Hz SWDs. Side effects occurred in 21% of patients. Manual file inspection identified 806 3-Hz SWDs of ≥3 s. The ML pipeline reduced a neurologist's median review time for 24-h wEEG from 27 (range = 10-45) to 4.3 min (range = .1-10), with a sensitivity, precision, F1-score, and false positives per hour of .8, .95, .87, and .007, respectively.

Significance: Home-based wEEG allows patient monitoring after ASM adjustments, improving absence seizure management. The ML-based pipeline performed well and was crucial in reducing review time.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Epilepsia
Epilepsia 医学-临床神经学
CiteScore
10.90
自引率
10.70%
发文量
319
审稿时长
2-4 weeks
期刊介绍: Epilepsia is the leading, authoritative source for innovative clinical and basic science research for all aspects of epilepsy and seizures. In addition, Epilepsia publishes critical reviews, opinion pieces, and guidelines that foster understanding and aim to improve the diagnosis and treatment of people with seizures and epilepsy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信