Study of factors influencing the insertion failure of single balloon enteroscopy-assisted ERCP treatment after bilioenteric Roux-en-Y anastomosis.

IF 2.5 3区 医学 Q2 GASTROENTEROLOGY & HEPATOLOGY
Weng Hao, Fan Qingquan, Gu Jun, Weng Mingzhe, Zhao Mingning, Zhang Yi, Xu Leiming, Shu Yijun, Wei Ding, AWang Suo Lang, Wang Xuefeng, Song Xiaoling
{"title":"Study of factors influencing the insertion failure of single balloon enteroscopy-assisted ERCP treatment after bilioenteric Roux-en-Y anastomosis.","authors":"Weng Hao, Fan Qingquan, Gu Jun, Weng Mingzhe, Zhao Mingning, Zhang Yi, Xu Leiming, Shu Yijun, Wei Ding, AWang Suo Lang, Wang Xuefeng, Song Xiaoling","doi":"10.1186/s12876-025-03689-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and study aims: </strong>Fail to reach the bilioenteric anastomosis is the main cause of treatment failure during single-balloon enteroscopy-assisted endoscopic retrograde cholangiopancreatography (SBE-assisted ERCP) in patients after bilioenteric Roux-en-Y anastomosis. We aim to evaluate factors influencing the endoscopic insertion failure.</p><p><strong>Patients and methods: </strong>We retrospectively reviewed the clinical data of 231 cases undergoing SBE-assisted ERCP from January 2016 to December 2021. Treatment details and outcomes were studied to analyze the factors involved in endoscopic insertion failure.</p><p><strong>Results: </strong>The enteroscopy success rate and procedural success rate were 88.3% and 84.4%. Incidence of postoperative adverse events was 3.9%. No serious adverse events occurred. Risk factors of endoscopic insertion failure include first ERCP attempt, side to side anastomosis at the Rou-Y anastomosis, the use of Endo-GIA anastomosis, three bowel lumens seen at the Rou-Y anastomosis under endoscopy, steep angle of the afferent loop at the Rou-Y anastomosis with a U-shape, length of the afferent loop ≥ 50 cm, and twisted afferent loop. Among which the multifactorial analysis suggested that the presence of three bowel lumens at the Rou-Y anastomosis and twisted afferent loop were independent risk factors for enteroscopy failure. For case with twisted afferent loop, the use of a transparent cap with X-ray-assisted guidance during insertion is an effective strategy to improve the success rate.</p><p><strong>Conclusions: </strong>SBE-assisted ERCP is safe and effective in patients after bilioenteric Roux-en-Y anastomosis. The severity of afferent loop twisting and Rou-Y anastomosis shape were risk factors for endoscopic insertion failure. Surgeons should take into account the feasibility of postoperative ERCP treatment at the time of operation.</p>","PeriodicalId":9129,"journal":{"name":"BMC Gastroenterology","volume":"25 1","pages":"187"},"PeriodicalIF":2.5000,"publicationDate":"2025-03-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11924908/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Gastroenterology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12876-025-03689-2","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background and study aims: Fail to reach the bilioenteric anastomosis is the main cause of treatment failure during single-balloon enteroscopy-assisted endoscopic retrograde cholangiopancreatography (SBE-assisted ERCP) in patients after bilioenteric Roux-en-Y anastomosis. We aim to evaluate factors influencing the endoscopic insertion failure.

Patients and methods: We retrospectively reviewed the clinical data of 231 cases undergoing SBE-assisted ERCP from January 2016 to December 2021. Treatment details and outcomes were studied to analyze the factors involved in endoscopic insertion failure.

Results: The enteroscopy success rate and procedural success rate were 88.3% and 84.4%. Incidence of postoperative adverse events was 3.9%. No serious adverse events occurred. Risk factors of endoscopic insertion failure include first ERCP attempt, side to side anastomosis at the Rou-Y anastomosis, the use of Endo-GIA anastomosis, three bowel lumens seen at the Rou-Y anastomosis under endoscopy, steep angle of the afferent loop at the Rou-Y anastomosis with a U-shape, length of the afferent loop ≥ 50 cm, and twisted afferent loop. Among which the multifactorial analysis suggested that the presence of three bowel lumens at the Rou-Y anastomosis and twisted afferent loop were independent risk factors for enteroscopy failure. For case with twisted afferent loop, the use of a transparent cap with X-ray-assisted guidance during insertion is an effective strategy to improve the success rate.

Conclusions: SBE-assisted ERCP is safe and effective in patients after bilioenteric Roux-en-Y anastomosis. The severity of afferent loop twisting and Rou-Y anastomosis shape were risk factors for endoscopic insertion failure. Surgeons should take into account the feasibility of postoperative ERCP treatment at the time of operation.

双肠 Roux-en-Y 吻合术后单球囊肠镜辅助 ERCP 治疗插入失败的影响因素研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
BMC Gastroenterology
BMC Gastroenterology 医学-胃肠肝病学
CiteScore
4.20
自引率
0.00%
发文量
465
审稿时长
6 months
期刊介绍: BMC Gastroenterology is an open access, peer-reviewed journal that considers articles on all aspects of the prevention, diagnosis and management of gastrointestinal and hepatobiliary disorders, as well as related molecular genetics, pathophysiology, and epidemiology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信