Per-Pixel Calibration Based on Multi-View 3D Reconstruction Errors Beyond the Depth of Field

Rong Dai;Wenpan Li;Yun-Hui Liu
{"title":"Per-Pixel Calibration Based on Multi-View 3D Reconstruction Errors Beyond the Depth of Field","authors":"Rong Dai;Wenpan Li;Yun-Hui Liu","doi":"10.1109/TIP.2025.3551165","DOIUrl":null,"url":null,"abstract":"In 3D microscopic imaging, the extremely shallow depth of field presents a challenge for accurate 3D reconstruction in cases of significant defocus. Traditional calibration methods rely on the spatial extraction of feature points to establish spatial 3D information as the optimization objective. However, these methods suffer from reduced extraction accuracy under defocus conditions, which causes degradation of calibration performance. To extend calibration volume without compromising accuracy in defocused scenarios, we propose a per-pixel calibration based on multi-view 3D reconstruction errors. It utilizes 3D reconstruction errors among different binocular setups as an optimization objective. We first analyze multi-view 3D reconstruction error distributions under the poor-accuracy optical model by employing a multi-view microscopic 3D measurement system using telecentric lenses. Subsequently, the 3D proportion model is proposed for implementing our error-based per-pixel calibration, derived as a spatial linear expression directly correlated with the 3D reconstruction error distribution. The experimental results confirm the robust convergence of our method with multiple binocular setups. Near the focus volume, the multi-view 3D reconstruction error remains approximately <inline-formula> <tex-math>$8~\\mu $ </tex-math></inline-formula> m (less than 0.5 camera pixel pitch), with absolute accuracy maintained within 0.5% of the measurement range. Beyond tenfold depth of field, the multi-view 3D reconstruction error increases to around <inline-formula> <tex-math>$30~\\mu $ </tex-math></inline-formula> m (still less than 2 camera pixel pitches), while absolute accuracy remains within 1% of the measurement range. These high-precision measurement results validate the feasibility and accuracy of our proposed calibration.","PeriodicalId":94032,"journal":{"name":"IEEE transactions on image processing : a publication of the IEEE Signal Processing Society","volume":"34 ","pages":"2124-2132"},"PeriodicalIF":0.0000,"publicationDate":"2025-03-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE transactions on image processing : a publication of the IEEE Signal Processing Society","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10934722/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In 3D microscopic imaging, the extremely shallow depth of field presents a challenge for accurate 3D reconstruction in cases of significant defocus. Traditional calibration methods rely on the spatial extraction of feature points to establish spatial 3D information as the optimization objective. However, these methods suffer from reduced extraction accuracy under defocus conditions, which causes degradation of calibration performance. To extend calibration volume without compromising accuracy in defocused scenarios, we propose a per-pixel calibration based on multi-view 3D reconstruction errors. It utilizes 3D reconstruction errors among different binocular setups as an optimization objective. We first analyze multi-view 3D reconstruction error distributions under the poor-accuracy optical model by employing a multi-view microscopic 3D measurement system using telecentric lenses. Subsequently, the 3D proportion model is proposed for implementing our error-based per-pixel calibration, derived as a spatial linear expression directly correlated with the 3D reconstruction error distribution. The experimental results confirm the robust convergence of our method with multiple binocular setups. Near the focus volume, the multi-view 3D reconstruction error remains approximately $8~\mu $ m (less than 0.5 camera pixel pitch), with absolute accuracy maintained within 0.5% of the measurement range. Beyond tenfold depth of field, the multi-view 3D reconstruction error increases to around $30~\mu $ m (still less than 2 camera pixel pitches), while absolute accuracy remains within 1% of the measurement range. These high-precision measurement results validate the feasibility and accuracy of our proposed calibration.
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信