Creating Perforations in the Sclerotic Region of the Proximal Tibia During Total Knee Arthroplasty to Enhance Prosthesis Stability.

IF 1.8 2区 医学 Q2 ORTHOPEDICS
Chao Sun, Chunyan Wang, Jintang Li, Chengyan Liu, Zhilin Wei, Zhiguo Bi, Yeran Li, Shuqiang Li
{"title":"Creating Perforations in the Sclerotic Region of the Proximal Tibia During Total Knee Arthroplasty to Enhance Prosthesis Stability.","authors":"Chao Sun, Chunyan Wang, Jintang Li, Chengyan Liu, Zhilin Wei, Zhiguo Bi, Yeran Li, Shuqiang Li","doi":"10.1111/os.70025","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>In patients with varus deformity of the knee, the redistribution of the subchondral bone mineral density (BMD) of the tibia leads to sclerotic zones that may cause osteoarthritis. Drilling the sclerotic area of the tibia prior to cementing during total knee arthroplasty is advisable practice. However, the extent of the sclerotic area and the effect of drilling on the tibial component are not well defined. We aimed to quantify the BMD and sclerotic bone distribution of the knee to clarify the effect of drilling on the stability of the prosthesis.</p><p><strong>Methods: </strong>Our retrospective cohort study enrolled a total of 97 patients from December 2018 to December 2019, categorized into drilled and nondrilled groups, with their computed tomography (CT) knee joint images documented. The proximal tibia image was divided into nine regions, the BMD of each region calculated, and CT values compared between the affected and normal sides. We established finite element models to analyze the drilling and stress distribution. The differences in CT values were assessed using the paired t test and Wilcoxon signed-rank test.</p><p><strong>Results: </strong>The mean thickness of sclerotic bone was 7.7 ± 1.4 mm, and the surface area was 441.9 ± 89.4 mm<sup>2</sup>. The CT values of the affected anteromedial, anterolateral, mediomedial, mediolateral, posteromedial, posteromedian, and posterolateral tibial areas were significantly higher than their normal counterparts. Stress concentration around the boreholes in all finite element models is minimal, with stress values ranging from 0.01 to 3.73 MPa, markedly lower than the 13.93 MPa observed in the undrilled model.</p><p><strong>Conclusion: </strong>Abnormal stress in the proximal tibia alters the distribution pattern of BMD, and drilling in the sclerotic area is associated with improved prosthesis stability.</p>","PeriodicalId":19566,"journal":{"name":"Orthopaedic Surgery","volume":" ","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2025-03-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Orthopaedic Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/os.70025","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: In patients with varus deformity of the knee, the redistribution of the subchondral bone mineral density (BMD) of the tibia leads to sclerotic zones that may cause osteoarthritis. Drilling the sclerotic area of the tibia prior to cementing during total knee arthroplasty is advisable practice. However, the extent of the sclerotic area and the effect of drilling on the tibial component are not well defined. We aimed to quantify the BMD and sclerotic bone distribution of the knee to clarify the effect of drilling on the stability of the prosthesis.

Methods: Our retrospective cohort study enrolled a total of 97 patients from December 2018 to December 2019, categorized into drilled and nondrilled groups, with their computed tomography (CT) knee joint images documented. The proximal tibia image was divided into nine regions, the BMD of each region calculated, and CT values compared between the affected and normal sides. We established finite element models to analyze the drilling and stress distribution. The differences in CT values were assessed using the paired t test and Wilcoxon signed-rank test.

Results: The mean thickness of sclerotic bone was 7.7 ± 1.4 mm, and the surface area was 441.9 ± 89.4 mm2. The CT values of the affected anteromedial, anterolateral, mediomedial, mediolateral, posteromedial, posteromedian, and posterolateral tibial areas were significantly higher than their normal counterparts. Stress concentration around the boreholes in all finite element models is minimal, with stress values ranging from 0.01 to 3.73 MPa, markedly lower than the 13.93 MPa observed in the undrilled model.

Conclusion: Abnormal stress in the proximal tibia alters the distribution pattern of BMD, and drilling in the sclerotic area is associated with improved prosthesis stability.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Orthopaedic Surgery
Orthopaedic Surgery ORTHOPEDICS-
CiteScore
3.40
自引率
14.30%
发文量
374
审稿时长
20 weeks
期刊介绍: Orthopaedic Surgery (OS) is the official journal of the Chinese Orthopaedic Association, focusing on all aspects of orthopaedic technique and surgery. The journal publishes peer-reviewed articles in the following categories: Original Articles, Clinical Articles, Review Articles, Guidelines, Editorials, Commentaries, Surgical Techniques, Case Reports and Meeting Reports.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信