Ami Miyoshi, Atsushi Ogata, Fumitaka Koga, Takashi Furukawa, Hiroshi Ito, Fumitaka Yoshioka, Jun Masuoka, Tatsuya Abe
{"title":"Novel Flow Reversal Technique Using Dual-Balloon Inflation for Right Common Carotid Artery Stenosis: A Technical Case Report.","authors":"Ami Miyoshi, Atsushi Ogata, Fumitaka Koga, Takashi Furukawa, Hiroshi Ito, Fumitaka Yoshioka, Jun Masuoka, Tatsuya Abe","doi":"10.5797/jnet.cr.2024-0104","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Herein, we present a novel flow reversal technique using dual-balloon inflation that can provide enhanced catheter stability and reliable embolic protection for percutaneous antegrade stenting in a patient with right common carotid artery (CCA) stenosis.</p><p><strong>Case presentation: </strong>A 75-year-old female patient with post-radiation right CCA stenosis initially underwent stenting using distal filter protection, which resulted in transient left upper limb paralysis caused by embolic infarction. After restenosis at 6 months, retreatment was performed using dual-balloon occlusion with the 9-F balloon guiding catheter in the innominate artery and the 8-F balloon guiding catheter in the right subclavian artery. Intraoperative ultrasonography confirmed a successful flow reversal, and debris was captured from the aspirated blood. The patient was discharged without neurological deficits, and postoperative imaging showed no new ischemic lesions.</p><p><strong>Conclusion: </strong>The novel flow reversal technique using dual-balloon inflation can be effective and safe for treating right CCA stenosis by achieving both reliable embolic protection and improved catheter stability.</p>","PeriodicalId":73856,"journal":{"name":"Journal of neuroendovascular therapy","volume":"19 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11911029/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of neuroendovascular therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5797/jnet.cr.2024-0104","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/3/13 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: Herein, we present a novel flow reversal technique using dual-balloon inflation that can provide enhanced catheter stability and reliable embolic protection for percutaneous antegrade stenting in a patient with right common carotid artery (CCA) stenosis.
Case presentation: A 75-year-old female patient with post-radiation right CCA stenosis initially underwent stenting using distal filter protection, which resulted in transient left upper limb paralysis caused by embolic infarction. After restenosis at 6 months, retreatment was performed using dual-balloon occlusion with the 9-F balloon guiding catheter in the innominate artery and the 8-F balloon guiding catheter in the right subclavian artery. Intraoperative ultrasonography confirmed a successful flow reversal, and debris was captured from the aspirated blood. The patient was discharged without neurological deficits, and postoperative imaging showed no new ischemic lesions.
Conclusion: The novel flow reversal technique using dual-balloon inflation can be effective and safe for treating right CCA stenosis by achieving both reliable embolic protection and improved catheter stability.