Utilizing CO2 Cone Beam Computed Tomography for Post-Procedure Completion Control Following Fenestrated Endovascular Repair of Complex Aortic Aneurysm With a Standardized CO2 Protocol.

IF 1.7 2区 医学 Q3 PERIPHERAL VASCULAR DISEASE
Davide Esposito, Martina Bastianon, Caterina Melani, Gaddiel Mozzetta, Endri Sila, Fabio Grimaldi, Enrica Bosisio, Andrea Savio, Giuseppe Baldino, Giovanni Pratesi
{"title":"Utilizing CO<sub>2</sub> Cone Beam Computed Tomography for Post-Procedure Completion Control Following Fenestrated Endovascular Repair of Complex Aortic Aneurysm With a Standardized CO<sub>2</sub> Protocol.","authors":"Davide Esposito, Martina Bastianon, Caterina Melani, Gaddiel Mozzetta, Endri Sila, Fabio Grimaldi, Enrica Bosisio, Andrea Savio, Giuseppe Baldino, Giovanni Pratesi","doi":"10.1177/15266028251327041","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To assess the feasibility and efficacy of a standardized CO<sub>2</sub> protocol and CO<sub>2</sub> cone beam computed tomography (CBCT) for procedural completion in fenestrated endovascular aneurysm repair (FEVAR) of complex aortic aneurysms in patients with chronic kidney disease (CKD).</p><p><strong>Materials and methods: </strong>Ten patients with complex aortic aneurysms and CKD (estimated glomerular filtration rate <90 ml/min) underwent FEVAR with custom-made fenestrated devices, using CO<sub>2</sub> as the primary contrast agent. Procedures were conducted in a hybrid operating room following a standardized CO<sub>2</sub> protocol with optimized injection parameters and visualization techniques to maximize CO<sub>2</sub> imaging efficacy. CO<sub>2</sub> CBCT was performed intraoperatively to verify stent graft deployment, bridging stent positioning, target vessel patency, and the presence of potential endoleaks.</p><p><strong>Results: </strong>All 10 procedures were completed successfully without intraoperative complications or CO<sub>2</sub>-related adverse effects. Completion CO<sub>2</sub> CBCT provided clear visualization of visceral and renal vessels, and no significant endoleaks were detected. One procedure was entirely iodine contrast-free, while minimal iodine contrast was used in others to address diagnostic uncertainties. Postoperative renal function remained stable across all patients.</p><p><strong>Conclusion: </strong>CO<sub>2</sub> CBCT is a feasible and effective alternative for completion imaging in complex FEVAR procedures for patients with CKD, potentially reducing the need for iodine contrast and the associated risk of nephropathy. A standardized CO<sub>2</sub> protocol can enhance procedural safety. Further research with larger cohorts is needed to confirm these findings.Clinical ImpactCO<sub>2</sub> serves as the preferred contrast medium for the endovascular treatment of patients with iodine contrast allergies or those afflicted with chronic kidney disease (CKD) to preserve further renal deterioration. Ensuring protection from potentially harmful substances is paramount during endovascular repair in such patients. Equally crucial is performing the procedure safely through a standardized protocol and confirming its accuracy upon completion. Nevertheless, the possibility of employing CO<sub>2</sub> for cone beam computed tomography provides invaluable insights into procedural efficacy, thereby enhancing outcomes for CKD patients undergoing complex endovascular repair.</p>","PeriodicalId":50210,"journal":{"name":"Journal of Endovascular Therapy","volume":" ","pages":"15266028251327041"},"PeriodicalIF":1.7000,"publicationDate":"2025-03-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Endovascular Therapy","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15266028251327041","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To assess the feasibility and efficacy of a standardized CO2 protocol and CO2 cone beam computed tomography (CBCT) for procedural completion in fenestrated endovascular aneurysm repair (FEVAR) of complex aortic aneurysms in patients with chronic kidney disease (CKD).

Materials and methods: Ten patients with complex aortic aneurysms and CKD (estimated glomerular filtration rate <90 ml/min) underwent FEVAR with custom-made fenestrated devices, using CO2 as the primary contrast agent. Procedures were conducted in a hybrid operating room following a standardized CO2 protocol with optimized injection parameters and visualization techniques to maximize CO2 imaging efficacy. CO2 CBCT was performed intraoperatively to verify stent graft deployment, bridging stent positioning, target vessel patency, and the presence of potential endoleaks.

Results: All 10 procedures were completed successfully without intraoperative complications or CO2-related adverse effects. Completion CO2 CBCT provided clear visualization of visceral and renal vessels, and no significant endoleaks were detected. One procedure was entirely iodine contrast-free, while minimal iodine contrast was used in others to address diagnostic uncertainties. Postoperative renal function remained stable across all patients.

Conclusion: CO2 CBCT is a feasible and effective alternative for completion imaging in complex FEVAR procedures for patients with CKD, potentially reducing the need for iodine contrast and the associated risk of nephropathy. A standardized CO2 protocol can enhance procedural safety. Further research with larger cohorts is needed to confirm these findings.Clinical ImpactCO2 serves as the preferred contrast medium for the endovascular treatment of patients with iodine contrast allergies or those afflicted with chronic kidney disease (CKD) to preserve further renal deterioration. Ensuring protection from potentially harmful substances is paramount during endovascular repair in such patients. Equally crucial is performing the procedure safely through a standardized protocol and confirming its accuracy upon completion. Nevertheless, the possibility of employing CO2 for cone beam computed tomography provides invaluable insights into procedural efficacy, thereby enhancing outcomes for CKD patients undergoing complex endovascular repair.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.30
自引率
15.40%
发文量
203
审稿时长
6-12 weeks
期刊介绍: The Journal of Endovascular Therapy (formerly the Journal of Endovascular Surgery) was established in 1994 as a forum for all physicians, scientists, and allied healthcare professionals who are engaged or interested in peripheral endovascular techniques and technology. An official publication of the International Society of Endovascular Specialists (ISEVS), the Journal of Endovascular Therapy publishes peer-reviewed articles of interest to clinicians and researchers in the field of peripheral endovascular interventions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信