Angular stable intramedullary nail versus locking plate fixation of osteoporotic surgical neck proximal humerus fractures: A biomechanical comparison.

IF 1.5 Q3 ORTHOPEDICS
Eric Samuelson, Elizabeth Lyden, Hani Haider, Armodios M Hatzidakis, Timothy Lackner, Bradford Zitsch, Edward V Fehringer
{"title":"Angular stable intramedullary nail versus locking plate fixation of osteoporotic surgical neck proximal humerus fractures: A biomechanical comparison.","authors":"Eric Samuelson, Elizabeth Lyden, Hani Haider, Armodios M Hatzidakis, Timothy Lackner, Bradford Zitsch, Edward V Fehringer","doi":"10.1177/17585732251324497","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Our study's purpose was to compare biomechanical performances of a proximal humerus locking plate (PHLP) with an antegrade intramedullary nail (IMN) in an osteoporotic two-part surgical neck proximal humerus fracture model.</p><p><strong>Methods: </strong>Simulated fractures were made through the surgical neck of synthetic osteoporotic humeri. One group had identical transverse fractures instrumented with a PHLP with seven screws (PHLP-7; <i>n</i> = 4), a PHLP with nine screws (PHLP-9; <i>n</i> = 2), or an IMN (<i>n</i> = 4). Each underwent pre-fatigue testing, an identical fatigue protocol, and post-fatigue testing. A second high oblique fracture line was tested identically with PHLP-9 (<i>n</i> = 4) and IMN (<i>n</i> = 4) constructs.</p><p><strong>Results: </strong>Statistical analyses of transverse specimen pre-fatigue stiffness revealed that the PHLP-7 and PHLP-9 were stiffer in anteroposterior bending and torsion compared to the IMN. There was no difference between the three constructs in varus-valgus bending or compression. Post-fatigue stiffness comparisons revealed no difference between the three constructs. For the oblique fracture, pre-fatigue differences were found with the IMN stiffer in varus-valgus bending and the PHLP-9 stiffer in torsion.</p><p><strong>Discussion: </strong>The biomechanical performance of an angular-stable proximal humeral nail design was comparable, especially following fatigue, to locked plate/screw constructs in a synthetic osteoporotic two-part surgical neck proximal humerus fracture model.</p>","PeriodicalId":36705,"journal":{"name":"Shoulder and Elbow","volume":" ","pages":"17585732251324497"},"PeriodicalIF":1.5000,"publicationDate":"2025-03-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11907631/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Shoulder and Elbow","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/17585732251324497","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Our study's purpose was to compare biomechanical performances of a proximal humerus locking plate (PHLP) with an antegrade intramedullary nail (IMN) in an osteoporotic two-part surgical neck proximal humerus fracture model.

Methods: Simulated fractures were made through the surgical neck of synthetic osteoporotic humeri. One group had identical transverse fractures instrumented with a PHLP with seven screws (PHLP-7; n = 4), a PHLP with nine screws (PHLP-9; n = 2), or an IMN (n = 4). Each underwent pre-fatigue testing, an identical fatigue protocol, and post-fatigue testing. A second high oblique fracture line was tested identically with PHLP-9 (n = 4) and IMN (n = 4) constructs.

Results: Statistical analyses of transverse specimen pre-fatigue stiffness revealed that the PHLP-7 and PHLP-9 were stiffer in anteroposterior bending and torsion compared to the IMN. There was no difference between the three constructs in varus-valgus bending or compression. Post-fatigue stiffness comparisons revealed no difference between the three constructs. For the oblique fracture, pre-fatigue differences were found with the IMN stiffer in varus-valgus bending and the PHLP-9 stiffer in torsion.

Discussion: The biomechanical performance of an angular-stable proximal humeral nail design was comparable, especially following fatigue, to locked plate/screw constructs in a synthetic osteoporotic two-part surgical neck proximal humerus fracture model.

研究背景我们的研究旨在比较肱骨近端锁定钢板(PHLP)和胫骨前髓内钉(IMN)在骨质疏松性两部分手术颈肱骨近端骨折模型中的生物力学性能:方法:通过合成骨质疏松肱骨的手术颈模拟骨折。其中一组的横向骨折完全相同,分别使用带 7 颗螺钉的 PHLP(PHLP-7;n = 4)、带 9 颗螺钉的 PHLP(PHLP-9;n = 2)或 IMN(n = 4)。每种方法都进行了疲劳前测试、相同的疲劳方案和疲劳后测试。对第二条高斜断裂线进行了与 PHLP-9 结构(n = 4)和 IMN 结构(n = 4)相同的测试:结果:对横向试样疲劳前刚度的统计分析显示,与 IMN 相比,PHLP-7 和 PHLP-9 在前后弯曲和扭转时的刚度更大。三种结构在屈曲-瓣膜弯曲或压缩方面没有差异。疲劳后硬度比较显示,三种结构之间没有差异。对于斜形骨折,疲劳前的差异被发现,IMN在屈曲-瓣膜弯曲时更硬,而PHLP-9在扭转时更硬:讨论:在合成骨质疏松两部分手术颈肱骨近端骨折模型中,角稳定肱骨近端钉设计的生物力学性能与锁定钢板/螺钉结构相当,尤其是在疲劳后。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Shoulder and Elbow
Shoulder and Elbow Medicine-Rehabilitation
CiteScore
2.80
自引率
0.00%
发文量
91
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信