Robert N Finnegan, Alexandra Quinn, Patrick Horsley, Joseph Chan, Maegan Stewart, Regina Bromley, Jeremy Booth
{"title":"Geometric and dosimetric evaluation of a commercial AI auto-contouring tool on multiple anatomical sites in CT scans.","authors":"Robert N Finnegan, Alexandra Quinn, Patrick Horsley, Joseph Chan, Maegan Stewart, Regina Bromley, Jeremy Booth","doi":"10.1002/acm2.70067","DOIUrl":null,"url":null,"abstract":"<p><p>Current radiotherapy practices rely on manual contouring of CT scans, which is time-consuming, prone to variability, and requires highly trained experts. There is a need for more efficient and consistent contouring methods. This study evaluated the performance of the Varian Ethos AI auto-contouring tool to assess its potential integration into clinical workflows. This retrospective study included 223 patients with treatment sites in the pelvis, abdomen, thorax, and head and neck regions. The Ethos AI tool generated auto-contours on each patients' pre-treatment planning CT, and 45 unique structures were included across the study cohort. Multiple measures of geometric similarity were computed, including surface Dice Similarity Coefficient (sDSC) and mean distance to agreement (MDA). Dosimetric concordance was evaluated by comparing mean dose and maximum 2 cm<sup>3</sup> dose (D<sub>2 cc</sub>) between manual and AI contours. Ethos AI demonstrated high geometric accuracy for well-defined structures like the bladder, lungs, and femoral heads. Smaller structures and those with less defined boundaries, such as optic nerves and duodenum, showed lower agreement. Over 70% of auto-contours demonstrated a sDSC > 0.8, and 74% had MDA < 2.5 mm. Geometric accuracy generally correlated with dosimetric concordance, however differences in contour definitions did result in some structures exhibiting dose deviations. The Ethos AI auto-contouring tool offers promising accuracy and reliability for many anatomical structures, supporting its use in planning workflows. Auto-contouring errors, although rare, highlight the importance of ongoing QA and expert manual oversight.</p>","PeriodicalId":14989,"journal":{"name":"Journal of Applied Clinical Medical Physics","volume":" ","pages":"e70067"},"PeriodicalIF":2.0000,"publicationDate":"2025-03-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Clinical Medical Physics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/acm2.70067","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Current radiotherapy practices rely on manual contouring of CT scans, which is time-consuming, prone to variability, and requires highly trained experts. There is a need for more efficient and consistent contouring methods. This study evaluated the performance of the Varian Ethos AI auto-contouring tool to assess its potential integration into clinical workflows. This retrospective study included 223 patients with treatment sites in the pelvis, abdomen, thorax, and head and neck regions. The Ethos AI tool generated auto-contours on each patients' pre-treatment planning CT, and 45 unique structures were included across the study cohort. Multiple measures of geometric similarity were computed, including surface Dice Similarity Coefficient (sDSC) and mean distance to agreement (MDA). Dosimetric concordance was evaluated by comparing mean dose and maximum 2 cm3 dose (D2 cc) between manual and AI contours. Ethos AI demonstrated high geometric accuracy for well-defined structures like the bladder, lungs, and femoral heads. Smaller structures and those with less defined boundaries, such as optic nerves and duodenum, showed lower agreement. Over 70% of auto-contours demonstrated a sDSC > 0.8, and 74% had MDA < 2.5 mm. Geometric accuracy generally correlated with dosimetric concordance, however differences in contour definitions did result in some structures exhibiting dose deviations. The Ethos AI auto-contouring tool offers promising accuracy and reliability for many anatomical structures, supporting its use in planning workflows. Auto-contouring errors, although rare, highlight the importance of ongoing QA and expert manual oversight.
期刊介绍:
Journal of Applied Clinical Medical Physics is an international Open Access publication dedicated to clinical medical physics. JACMP welcomes original contributions dealing with all aspects of medical physics from scientists working in the clinical medical physics around the world. JACMP accepts only online submission.
JACMP will publish:
-Original Contributions: Peer-reviewed, investigations that represent new and significant contributions to the field. Recommended word count: up to 7500.
-Review Articles: Reviews of major areas or sub-areas in the field of clinical medical physics. These articles may be of any length and are peer reviewed.
-Technical Notes: These should be no longer than 3000 words, including key references.
-Letters to the Editor: Comments on papers published in JACMP or on any other matters of interest to clinical medical physics. These should not be more than 1250 (including the literature) and their publication is only based on the decision of the editor, who occasionally asks experts on the merit of the contents.
-Book Reviews: The editorial office solicits Book Reviews.
-Announcements of Forthcoming Meetings: The Editor may provide notice of forthcoming meetings, course offerings, and other events relevant to clinical medical physics.
-Parallel Opposed Editorial: We welcome topics relevant to clinical practice and medical physics profession. The contents can be controversial debate or opposed aspects of an issue. One author argues for the position and the other against. Each side of the debate contains an opening statement up to 800 words, followed by a rebuttal up to 500 words. Readers interested in participating in this series should contact the moderator with a proposed title and a short description of the topic