Use of Glucose Monitoring Devices Among Adults with Diabetes in Germany: Results from Nationwide Surveys Conducted in 2017 and 2021/2022.

IF 5.7 2区 医学 Q1 ENDOCRINOLOGY & METABOLISM
Yong Du, Jens Baumert, Maike Buchmann, Reinhard W Holl, Christin Heidemann
{"title":"Use of Glucose Monitoring Devices Among Adults with Diabetes in Germany: Results from Nationwide Surveys Conducted in 2017 and 2021/2022.","authors":"Yong Du, Jens Baumert, Maike Buchmann, Reinhard W Holl, Christin Heidemann","doi":"10.1089/dia.2024.0623","DOIUrl":null,"url":null,"abstract":"<p><p><b><i>Background:</i></b> Devices for continuous glucose monitoring (CGM) have been developed to optimize blood glucose control and liberate people with diabetes from finger-prick glucose measurements. Since 2016, the devices have been reimbursed in Germany for people with diabetes receiving insulin therapy, resulting in their increased use among people with type 1 diabetes (T1D) and type 2 diabetes (T2D). We investigated the prevalence of CGM use and its associated factors among German adults with diabetes in 2017 and 2021/2022. <b><i>Methods:</i></b> Participants aged 18 years or older with diagnosed diabetes were identified from two nationwide population-based telephone surveys in 2017 (<i>n</i> = 1396) and 2021/2022 (<i>n</i> = 1456). Prevalence and dynamics of CGM use were examined overall and stratified by sociodemographic and diabetes-related characteristics. Factors associated with CGM use were obtained from logistic regression models. <b><i>Results:</i></b> The overall prevalence of CGM use was 8.2% in 2017 and 16.6% in 2021/2022. An increase in CGM use was observed across all the subgroups except for those without antidiabetic medications. CGM use increased from 31.1% to 75.4% in adults with T1D, from 6.3% to 13.6% in adults with T2D, and from 14.6% to 36.7% in all insulin users. In both surveys, younger age, insulin use, T1D, and reporting hypoglycemia were associated with CGM use. In addition, in 2017, higher education level and absence of obesity were associated with CGM use, whereas in 2021/2022, participation in the diabetes self-management education program and higher self-assessed quality of diabetes care were associated with CGM use. <b><i>Conclusion:</i></b> Among adults with diabetes in Germany, CGM use increased about twofold within 5 years, irrespective of sociodemographic factors. Educational inequality in CGM use diminished over time. The higher self-rated quality of diabetes care associated with the recent use of CGM provides further evidence to support its use among all adults with diabetes in Germany.</p>","PeriodicalId":11159,"journal":{"name":"Diabetes technology & therapeutics","volume":" ","pages":""},"PeriodicalIF":5.7000,"publicationDate":"2025-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diabetes technology & therapeutics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1089/dia.2024.0623","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Devices for continuous glucose monitoring (CGM) have been developed to optimize blood glucose control and liberate people with diabetes from finger-prick glucose measurements. Since 2016, the devices have been reimbursed in Germany for people with diabetes receiving insulin therapy, resulting in their increased use among people with type 1 diabetes (T1D) and type 2 diabetes (T2D). We investigated the prevalence of CGM use and its associated factors among German adults with diabetes in 2017 and 2021/2022. Methods: Participants aged 18 years or older with diagnosed diabetes were identified from two nationwide population-based telephone surveys in 2017 (n = 1396) and 2021/2022 (n = 1456). Prevalence and dynamics of CGM use were examined overall and stratified by sociodemographic and diabetes-related characteristics. Factors associated with CGM use were obtained from logistic regression models. Results: The overall prevalence of CGM use was 8.2% in 2017 and 16.6% in 2021/2022. An increase in CGM use was observed across all the subgroups except for those without antidiabetic medications. CGM use increased from 31.1% to 75.4% in adults with T1D, from 6.3% to 13.6% in adults with T2D, and from 14.6% to 36.7% in all insulin users. In both surveys, younger age, insulin use, T1D, and reporting hypoglycemia were associated with CGM use. In addition, in 2017, higher education level and absence of obesity were associated with CGM use, whereas in 2021/2022, participation in the diabetes self-management education program and higher self-assessed quality of diabetes care were associated with CGM use. Conclusion: Among adults with diabetes in Germany, CGM use increased about twofold within 5 years, irrespective of sociodemographic factors. Educational inequality in CGM use diminished over time. The higher self-rated quality of diabetes care associated with the recent use of CGM provides further evidence to support its use among all adults with diabetes in Germany.

德国成人糖尿病患者血糖监测设备的使用:2017年和2021/2022年进行的全国调查结果
背景:为了优化血糖控制,将糖尿病患者从手指点刺血糖测量中解放出来,已经开发出了连续血糖监测(CGM)设备。自2016年以来,德国已经为接受胰岛素治疗的糖尿病患者报销了这种设备,导致1型糖尿病(T1D)和2型糖尿病(T2D)患者使用这种设备的人数增加。我们调查了2017年和2021/2022年德国成人糖尿病患者中CGM的使用情况及其相关因素。方法:从2017年(n = 1396)和2021/2022年(n = 1456)两次全国人口电话调查中确定18岁及以上诊断为糖尿病的参与者。通过社会人口学和糖尿病相关特征对CGM使用的流行率和动态进行了总体和分层检查。通过逻辑回归模型获得与CGM使用相关的因素。结果:2017年CGM总体使用率为8.2%,2021/2022年为16.6%。除未使用抗糖尿病药物的亚组外,所有亚组均观察到CGM的使用增加。T1D患者的CGM使用率从31.1%增加到75.4%,T2D患者的CGM使用率从6.3%增加到13.6%,所有胰岛素使用者的CGM使用率从14.6%增加到36.7%。在两项调查中,年龄较小、胰岛素使用、T1D和报告低血糖与CGM使用相关。此外,2017年,高等教育水平和无肥胖与CGM使用相关,而2021/2022年,参与糖尿病自我管理教育计划和较高的糖尿病护理自我评估质量与CGM使用相关。结论:在德国的成人糖尿病患者中,CGM的使用在5年内增加了约两倍,与社会人口因素无关。CGM使用中的教育不平等随着时间的推移而减少。与近期使用CGM相关的较高的糖尿病护理自评质量提供了进一步的证据,支持其在德国所有成人糖尿病患者中使用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Diabetes technology & therapeutics
Diabetes technology & therapeutics 医学-内分泌学与代谢
CiteScore
10.60
自引率
14.80%
发文量
145
审稿时长
3-8 weeks
期刊介绍: Diabetes Technology & Therapeutics is the only peer-reviewed journal providing healthcare professionals with information on new devices, drugs, drug delivery systems, and software for managing patients with diabetes. This leading international journal delivers practical information and comprehensive coverage of cutting-edge technologies and therapeutics in the field, and each issue highlights new pharmacological and device developments to optimize patient care.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信