An MR-only deep learning inference model-based dose estimation algorithm for MR-guided adaptive radiation therapy.

Medical physics Pub Date : 2025-03-16 DOI:10.1002/mp.17759
Zhiqiang Liu, Kuo Men, Weigang Hu, Jianrong Dai, Jiawei Fan
{"title":"An MR-only deep learning inference model-based dose estimation algorithm for MR-guided adaptive radiation therapy.","authors":"Zhiqiang Liu, Kuo Men, Weigang Hu, Jianrong Dai, Jiawei Fan","doi":"10.1002/mp.17759","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Magnetic resonance-guided adaptive radiation therapy (MRgART) systems combine Magnetic resonance imaging (MRI) technology with linear accelerators (LINAC) to enhance the precision and efficacy of cancer treatment. These systems enable real-time adjustments of treatment plans based on the latest patient anatomy, creating an urgent need for accurate and rapid dose calculation algorithms. Traditional CT-based dose calculations and ray-tracing (RT) processes are time-consuming and may not be feasible for the online adaptive workflow required in MRgART. Recent advancements in deep learning (DL) offer promising solutions to overcome these limitations.</p><p><strong>Purpose: </strong>This study aims to develop a DL-based dose calculation engine for MRgART that relies solely on MR images. This approach addresses the critical need for accurate and rapid dose calculations in the MRgART workflow without relying on CT images or time-consuming RT processes.</p><p><strong>Methods: </strong>We used a deep residual network inspired by U-Net to establish a direct connection between distance-corrected conical (DCC) fluence maps and dose distributions in the image domain. The study utilized data from 30 prostate cancer patients treated with fixed-beam Intensity-Modulated Radiation Therapy (IMRT) on an MR-guided LINAC system. We trained, validated, and tested the model using a total of 120 online treatment plans, which encompassed 1080 individual beams. We extensively evaluated the network's performance by comparing its dose calculation accuracy against Monte Carlo (MC)-based methods using metrics such as mean absolute error (MAE) of pixel-wise dose differences, 3D gamma analysis, dose-volume histograms (DVHs), dosimetric indices, and isodose line similarity.</p><p><strong>Results: </strong>The proposed DL model demonstrated high accuracy in dose calculations. The median MAE of pixel-wise dose differences was 1.2% for the whole body, 1.9% for targets, and 1.1% for organs at risk (OARs). The median 3D gamma passing rates for the 3%/3  mm criterion were 94.8% for the whole body, 95.7% for targets, and 98.7% for OARs. Additionally, the Dice similarity coefficient (DSC) of isodose lines between the DL-based and MC-based dose calculations averaged 0.94 ± 0.01. There were no big differences between the DL-based and MC-based calculations in the DVH curves and clinical dosimetric indices. This proved that the two methods were clinically equivalent.</p><p><strong>Conclusion: </strong>This study presents a novel MR-only dose calculation engine that eliminates the need for CT images and complex RT processes. By leveraging DL, the proposed method significantly enhances the efficiency and accuracy of the MRgART workflow, particularly for prostate cancer treatment. This approach holds potential for broader applications across different cancer types and MR-linac systems, paving the way for more streamlined and precise radiation therapy planning.</p>","PeriodicalId":94136,"journal":{"name":"Medical physics","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-03-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/mp.17759","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Magnetic resonance-guided adaptive radiation therapy (MRgART) systems combine Magnetic resonance imaging (MRI) technology with linear accelerators (LINAC) to enhance the precision and efficacy of cancer treatment. These systems enable real-time adjustments of treatment plans based on the latest patient anatomy, creating an urgent need for accurate and rapid dose calculation algorithms. Traditional CT-based dose calculations and ray-tracing (RT) processes are time-consuming and may not be feasible for the online adaptive workflow required in MRgART. Recent advancements in deep learning (DL) offer promising solutions to overcome these limitations.

Purpose: This study aims to develop a DL-based dose calculation engine for MRgART that relies solely on MR images. This approach addresses the critical need for accurate and rapid dose calculations in the MRgART workflow without relying on CT images or time-consuming RT processes.

Methods: We used a deep residual network inspired by U-Net to establish a direct connection between distance-corrected conical (DCC) fluence maps and dose distributions in the image domain. The study utilized data from 30 prostate cancer patients treated with fixed-beam Intensity-Modulated Radiation Therapy (IMRT) on an MR-guided LINAC system. We trained, validated, and tested the model using a total of 120 online treatment plans, which encompassed 1080 individual beams. We extensively evaluated the network's performance by comparing its dose calculation accuracy against Monte Carlo (MC)-based methods using metrics such as mean absolute error (MAE) of pixel-wise dose differences, 3D gamma analysis, dose-volume histograms (DVHs), dosimetric indices, and isodose line similarity.

Results: The proposed DL model demonstrated high accuracy in dose calculations. The median MAE of pixel-wise dose differences was 1.2% for the whole body, 1.9% for targets, and 1.1% for organs at risk (OARs). The median 3D gamma passing rates for the 3%/3  mm criterion were 94.8% for the whole body, 95.7% for targets, and 98.7% for OARs. Additionally, the Dice similarity coefficient (DSC) of isodose lines between the DL-based and MC-based dose calculations averaged 0.94 ± 0.01. There were no big differences between the DL-based and MC-based calculations in the DVH curves and clinical dosimetric indices. This proved that the two methods were clinically equivalent.

Conclusion: This study presents a novel MR-only dose calculation engine that eliminates the need for CT images and complex RT processes. By leveraging DL, the proposed method significantly enhances the efficiency and accuracy of the MRgART workflow, particularly for prostate cancer treatment. This approach holds potential for broader applications across different cancer types and MR-linac systems, paving the way for more streamlined and precise radiation therapy planning.

求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信