Sigma metrics for assessing the analytical performance of 14 biochemical analytes in Mansoura university children's hospital laboratories (MUCHLs) using CLIA LIMITS 1988 & 2024.

IF 2.1 4区 医学 Q3 MEDICAL LABORATORY TECHNOLOGY
Nada Karam, Reham M El-Farahaty, Abdel-Hady El-Gilany, Nessma A Nosser
{"title":"Sigma metrics for assessing the analytical performance of 14 biochemical analytes in Mansoura university children's hospital laboratories (MUCHLs) using CLIA LIMITS 1988 & 2024.","authors":"Nada Karam, Reham M El-Farahaty, Abdel-Hady El-Gilany, Nessma A Nosser","doi":"10.1177/00045632251330163","DOIUrl":null,"url":null,"abstract":"<p><p>IntroductionAnalytical quality is a crucial prerequisite for best practice in medical laboratory. Six-Sigma Methodology (SM) is a quality measurement tool used to evaluate laboratory performance. This study aims to assess the analytical phase baseline performance using SM and compare results using TEa of CLIA 1988 and CLIA 2024.Materials and methodsCoefficient of variation and bias were determined for 14 analytes. The sigma level for each parameter was calculated using total allowable error (TEa) for CLIA 1988 and CLIA 2024. The quality goal index ratio was calculated for analytes with Sigma less than 3. Normalized method decision Charts were plotted for level 1 and 2 Bio-Rad internal quality control for both CLIA 1988 and 2024.ResultsUsing CLIA TEa 1988, HDL-C, triglycerides & uric acid for level 1 and ALT, AST, HDL-C, calcium, triglycerides & uric acid for level 2 had six Sigma world class performance, meanwhile, only BUN for level 1 and 2 performed less than 3. Using CLIA TEa 2024, HDL-C, GGT, and triglycerides for level 1 and ALT, AST, calcium, GGT, and triglycerides for level 2 had world class quality performance. Meanwhile, creatinine, glucose, BUN for level 1 and BUN and creatinine for level 2 performed less than 3.ConclusionEvaluation of baseline analytical performance using SM revealed lower sigma values with stringent CLIA TEa 2024 versus tolerant CLIA TEa 1988. Improvement in the methodology of analytes with poor performance on some assay platforms with stringent quality control regimes is recommended.</p>","PeriodicalId":8005,"journal":{"name":"Annals of Clinical Biochemistry","volume":" ","pages":"45632251330163"},"PeriodicalIF":2.1000,"publicationDate":"2025-03-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Clinical Biochemistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/00045632251330163","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

IntroductionAnalytical quality is a crucial prerequisite for best practice in medical laboratory. Six-Sigma Methodology (SM) is a quality measurement tool used to evaluate laboratory performance. This study aims to assess the analytical phase baseline performance using SM and compare results using TEa of CLIA 1988 and CLIA 2024.Materials and methodsCoefficient of variation and bias were determined for 14 analytes. The sigma level for each parameter was calculated using total allowable error (TEa) for CLIA 1988 and CLIA 2024. The quality goal index ratio was calculated for analytes with Sigma less than 3. Normalized method decision Charts were plotted for level 1 and 2 Bio-Rad internal quality control for both CLIA 1988 and 2024.ResultsUsing CLIA TEa 1988, HDL-C, triglycerides & uric acid for level 1 and ALT, AST, HDL-C, calcium, triglycerides & uric acid for level 2 had six Sigma world class performance, meanwhile, only BUN for level 1 and 2 performed less than 3. Using CLIA TEa 2024, HDL-C, GGT, and triglycerides for level 1 and ALT, AST, calcium, GGT, and triglycerides for level 2 had world class quality performance. Meanwhile, creatinine, glucose, BUN for level 1 and BUN and creatinine for level 2 performed less than 3.ConclusionEvaluation of baseline analytical performance using SM revealed lower sigma values with stringent CLIA TEa 2024 versus tolerant CLIA TEa 1988. Improvement in the methodology of analytes with poor performance on some assay platforms with stringent quality control regimes is recommended.

曼苏拉大学儿童医院实验室(MUCHLs) 14种生化分析物分析性能的Sigma指标使用CLIA LIMITS 1988和2024。
分析质量是医学实验室最佳实践的重要前提。六西格玛方法(SM)是一种用于评价实验室绩效的质量测量工具。本研究旨在利用SM评估分析相基线性能,并比较CLIA 1988和CLIA 2024的TEa结果。材料和方法:测定了14种分析物的变异系数和偏倚系数。利用CLIA 1988和CLIA 2024的总允许误差(TEa)计算各参数的sigma水平。对Sigma小于3的分析物计算质量目标指标比。为CLIA 1988和2024的1级和2级Bio-Rad内部质量控制绘制了归一化方法决策图。结果:采用CLIA TEa 1988, HDL-C、甘油三酯和尿酸水平为1级,ALT、AST、HDL-C、钙、甘油三酯和尿酸水平为2级,达到6 Sigma世界级水平,只有BUN水平为1级和2级低于3。使用CLIA TEa 2024, HDL-C、GGT和甘油三酯为1级,ALT、AST、钙、GGT和甘油三酯为2级具有世界级的质量表现。同时,肌酐、葡萄糖、BUN为1级,BUN和肌酐为2级,均小于3级。结论:使用SM评估基线分析性能显示,严格的CLIA TEa 2024与宽容的CLIA TEa 1988相比,西格玛值更低。建议在一些具有严格质量控制制度的分析平台上改进性能较差的分析物的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Annals of Clinical Biochemistry
Annals of Clinical Biochemistry Biochemistry, Genetics and Molecular Biology-Clinical Biochemistry
CiteScore
5.20
自引率
4.50%
发文量
61
期刊介绍: Annals of Clinical Biochemistry is the fully peer reviewed international journal of the Association for Clinical Biochemistry and Laboratory Medicine. Annals of Clinical Biochemistry accepts papers that contribute to knowledge in all fields of laboratory medicine, especially those pertaining to the understanding, diagnosis and treatment of human disease. It publishes papers on clinical biochemistry, clinical audit, metabolic medicine, immunology, genetics, biotechnology, haematology, microbiology, computing and management where they have both biochemical and clinical relevance. Papers describing evaluation or implementation of commercial reagent kits or the performance of new analysers require substantial original information. Unless of exceptional interest and novelty, studies dealing with the redox status in various diseases are not generally considered within the journal''s scope. Studies documenting the association of single nucleotide polymorphisms (SNPs) with particular phenotypes will not normally be considered, given the greater strength of genome wide association studies (GWAS). Research undertaken in non-human animals will not be considered for publication in the Annals. Annals of Clinical Biochemistry is also the official journal of NVKC (de Nederlandse Vereniging voor Klinische Chemie) and JSCC (Japan Society of Clinical Chemistry).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信