{"title":"Testing the Feasibility of Selected, Commercially Available Wearable Devices in Detecting Agricultural-Related Incidents.","authors":"Aaron James Etienne, William E Field, Shawn G Ehlers, Roger Tormoehlen, Noah Joel Haslett","doi":"10.13031/jash.15985","DOIUrl":null,"url":null,"abstract":"<p><strong>Highlights: </strong>The purpose of this research was to validate a test procedure for using commercially available smart technologies in detecting an agricultural-related incident. A convenient selection of commercially available wearable devices was used to measure the inertial qualities of simulated incidents. Simulated ejections, falls, and upsets were performed to recreate leading causes of agricultural injuries and fatalities using an anthropomorphic test device. Only 2 of 27 simulated incidents triggered detection on the selected wearable devices tested. The results of this study were inconclusive in determining the feasibility of commercially available wearable devices in detecting agricultural-related incidents. More research is needed to develop an improved testing procedure. Additional collaboration is needed with manufacturers of wearable incident detection devices to clearly identify potential applications and limitations of their devices.</p><p><strong>Abstract: </strong>A study was conducted to test a selection of commercially available wearable devices to determine their feasibility for triggering incident detection during a variety of simulated agricultural incidents with high risk of causing injury. The goal was to ultimately increase survivability outcomes for victims by enhancing notification and reducing response time from emergency services. A 50th percentile adult male anthropomorphic test device (ATD). was fitted with a convenient selection of commercially available wearable smart technologies to measure the responsiveness of the technology's incident detection software. Devices used for this testing were: (1) Garmin Vivoactive 4 smartwatch; (2) Apple Watch Series 7 (Bluetooth only and cellular models); and (3) Movesense Active tracking device. A Samsung Galaxy S22 smartphone and an Apple iPhone 12 smartphone were used to connect the wearable devices and measured impact through their internal inertial measurement unit (IMU) sensors. Simulated ejections from equipment, vertical falls, and vehicle overturns were performed with the ATD. Side upsets were simulated with the ATD positioned in the operator station of a 52-drawbar horsepower (dbp), two-wheel drive, standard front axle, diesel tractor, weighing 6500 pounds. The tractor was equipped with an approved ROPS. Side upsets were also simulated using a 22-horsepower zero-turn mower, with the ATD positioned in the operator seat. Falls were simulated from heights of up to 4.57 meters. After each simulated incident, devices were examined to determine whether or not incident detection was successfully triggered. Data was then collected from an internal sensor logging application installed on the selected devices. It was found that the incident detection feature on the identified wearable devices only triggered in specific scenarios. Only 2 of the 27 simulated incidents successfully triggered incident detection on one device. Only the Garmin Vivoactive 4 smartwatch triggered incident detection. No device was triggered during the ATD impact in simulated tractor upset testing or in simulated zero-turn mower upset testing. It was concluded that these devices, in their current form, are not reliable for use in detecting serious agricultural-related injuries, especially considering the lack of adequate cell phone coverage in the areas in which these incidents are most likely to occur.</p>","PeriodicalId":45344,"journal":{"name":"Journal of Agricultural Safety and Health","volume":"30 4","pages":"181-204"},"PeriodicalIF":0.9000,"publicationDate":"2024-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Agricultural Safety and Health","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.13031/jash.15985","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH","Score":null,"Total":0}
引用次数: 0

Abstract

Highlights: The purpose of this research was to validate a test procedure for using commercially available smart technologies in detecting an agricultural-related incident. A convenient selection of commercially available wearable devices was used to measure the inertial qualities of simulated incidents. Simulated ejections, falls, and upsets were performed to recreate leading causes of agricultural injuries and fatalities using an anthropomorphic test device. Only 2 of 27 simulated incidents triggered detection on the selected wearable devices tested. The results of this study were inconclusive in determining the feasibility of commercially available wearable devices in detecting agricultural-related incidents. More research is needed to develop an improved testing procedure. Additional collaboration is needed with manufacturers of wearable incident detection devices to clearly identify potential applications and limitations of their devices.

Abstract: A study was conducted to test a selection of commercially available wearable devices to determine their feasibility for triggering incident detection during a variety of simulated agricultural incidents with high risk of causing injury. The goal was to ultimately increase survivability outcomes for victims by enhancing notification and reducing response time from emergency services. A 50th percentile adult male anthropomorphic test device (ATD). was fitted with a convenient selection of commercially available wearable smart technologies to measure the responsiveness of the technology's incident detection software. Devices used for this testing were: (1) Garmin Vivoactive 4 smartwatch; (2) Apple Watch Series 7 (Bluetooth only and cellular models); and (3) Movesense Active tracking device. A Samsung Galaxy S22 smartphone and an Apple iPhone 12 smartphone were used to connect the wearable devices and measured impact through their internal inertial measurement unit (IMU) sensors. Simulated ejections from equipment, vertical falls, and vehicle overturns were performed with the ATD. Side upsets were simulated with the ATD positioned in the operator station of a 52-drawbar horsepower (dbp), two-wheel drive, standard front axle, diesel tractor, weighing 6500 pounds. The tractor was equipped with an approved ROPS. Side upsets were also simulated using a 22-horsepower zero-turn mower, with the ATD positioned in the operator seat. Falls were simulated from heights of up to 4.57 meters. After each simulated incident, devices were examined to determine whether or not incident detection was successfully triggered. Data was then collected from an internal sensor logging application installed on the selected devices. It was found that the incident detection feature on the identified wearable devices only triggered in specific scenarios. Only 2 of the 27 simulated incidents successfully triggered incident detection on one device. Only the Garmin Vivoactive 4 smartwatch triggered incident detection. No device was triggered during the ATD impact in simulated tractor upset testing or in simulated zero-turn mower upset testing. It was concluded that these devices, in their current form, are not reliable for use in detecting serious agricultural-related injuries, especially considering the lack of adequate cell phone coverage in the areas in which these incidents are most likely to occur.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Agricultural Safety and Health
Journal of Agricultural Safety and Health PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH-
CiteScore
1.50
自引率
20.00%
发文量
10
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信