{"title":"How to indicate implantable cardioverter-defibrillator in the aging population","authors":"Risako Orita,&nbsp;Naoya Kataoka MD, PhD,&nbsp;Teruhiko Imamura MD, PhD","doi":"10.1002/joa3.70038","DOIUrl":null,"url":null,"abstract":"<p>To Editor,</p><p>The optimal indication for implantable cardioverter-defibrillator (ICD) implantation in the aging population remains a subject of debate, given the high incidence of nonarrhythmic mortality in this cohort. The authors have investigated the clinical outcomes of octogenarians undergoing ICD implantation for both primary and secondary prevention, with a focus on ICD therapies and the timing of mortality.<span><sup>1</sup></span> Their findings suggest that while device utilization was infrequent, it preceded mortality by a significant margin. This may encourage clinicians to adopt a more aggressive approach to ICD implantation, even in elderly patients. However, several concerns warrant consideration.</p><p>A prior large-scale study evaluating the clinical implications of ICD generator replacement in the aging population reported that a substantial proportion of patients over 80 years of age succumbed before experiencing appropriate device utilization.<span><sup>2</sup></span> The discrepancy between these findings may stem from differences in baseline patient characteristics. Could the authors provide data on the proportion of patients who received guideline-directed medical therapy, which is known to mitigate arrhythmic events? Additionally, how many patients underwent catheter ablation for ventricular arrhythmias? Given that aggressive catheter ablation can reduce arrhythmic burden and thereby decrease the need for ICD intervention,<span><sup>3</sup></span> this information would be critical for contextualizing the study's findings.</p><p>Furthermore, the exclusion of patients with an observation period of fewer than 30 days raises concerns,<span><sup>1</sup></span> as these individuals may be at particularly high risk for arrhythmic events. Their omission could potentially bias the results and limit the generalizability of the study.</p><p>In the present study, approximately 20% of patients received cardiac resynchronization therapy (CRT),<span><sup>1</sup></span> which promotes cardiac reverse remodeling and may reduce the incidence of ventricular arrhythmias. The impact of CRT on preventing appropriate ICD utilization likely differs from that observed in patients with ICD implantation alone. Clarification on this point would enhance the interpretation of the findings.</p><p>Finally, the risk of device-related complications, including bleeding and infection, remains a significant concern, particularly in elderly patients with multiple comorbidities.<span><sup>4</sup></span> These risks must be carefully weighed against the potential benefits of ICD implantation in this population.</p><p>The authors declare no conflict of interest.</p>","PeriodicalId":15174,"journal":{"name":"Journal of Arrhythmia","volume":"41 2","pages":""},"PeriodicalIF":2.2000,"publicationDate":"2025-03-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/joa3.70038","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Arrhythmia","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/joa3.70038","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

To Editor,

The optimal indication for implantable cardioverter-defibrillator (ICD) implantation in the aging population remains a subject of debate, given the high incidence of nonarrhythmic mortality in this cohort. The authors have investigated the clinical outcomes of octogenarians undergoing ICD implantation for both primary and secondary prevention, with a focus on ICD therapies and the timing of mortality.1 Their findings suggest that while device utilization was infrequent, it preceded mortality by a significant margin. This may encourage clinicians to adopt a more aggressive approach to ICD implantation, even in elderly patients. However, several concerns warrant consideration.

A prior large-scale study evaluating the clinical implications of ICD generator replacement in the aging population reported that a substantial proportion of patients over 80 years of age succumbed before experiencing appropriate device utilization.2 The discrepancy between these findings may stem from differences in baseline patient characteristics. Could the authors provide data on the proportion of patients who received guideline-directed medical therapy, which is known to mitigate arrhythmic events? Additionally, how many patients underwent catheter ablation for ventricular arrhythmias? Given that aggressive catheter ablation can reduce arrhythmic burden and thereby decrease the need for ICD intervention,3 this information would be critical for contextualizing the study's findings.

Furthermore, the exclusion of patients with an observation period of fewer than 30 days raises concerns,1 as these individuals may be at particularly high risk for arrhythmic events. Their omission could potentially bias the results and limit the generalizability of the study.

In the present study, approximately 20% of patients received cardiac resynchronization therapy (CRT),1 which promotes cardiac reverse remodeling and may reduce the incidence of ventricular arrhythmias. The impact of CRT on preventing appropriate ICD utilization likely differs from that observed in patients with ICD implantation alone. Clarification on this point would enhance the interpretation of the findings.

Finally, the risk of device-related complications, including bleeding and infection, remains a significant concern, particularly in elderly patients with multiple comorbidities.4 These risks must be carefully weighed against the potential benefits of ICD implantation in this population.

The authors declare no conflict of interest.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Arrhythmia
Journal of Arrhythmia CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
2.90
自引率
10.00%
发文量
127
审稿时长
45 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信