Initial demonstration of the Scratch-PET concept: an intraoperative PET with a hand-held detector.

IF 1.7 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Taiyo Ishikawa, Yuma Iwao, Go Akamatsu, Sodai Takyu, Hideaki Tashima, Takayuki Okamoto, Taiga Yamaya, Hideaki Haneishi
{"title":"Initial demonstration of the Scratch-PET concept: an intraoperative PET with a hand-held detector.","authors":"Taiyo Ishikawa, Yuma Iwao, Go Akamatsu, Sodai Takyu, Hideaki Tashima, Takayuki Okamoto, Taiga Yamaya, Hideaki Haneishi","doi":"10.1007/s12194-025-00889-z","DOIUrl":null,"url":null,"abstract":"<p><p>Positron emission tomography (PET) is a valuable tool for diagnosing malignant tumors. Intraoperative PET imaging is expected to allow the more accurate localization of tumors that need resections. However, conventional devices feature a large detector ring that obstructs surgical procedures, preventing their intraoperative application. This paper proposes a new PET device, Scratch-PET, for image-guided tumor resection. The key feature of Scratch-PET is its use of a hand-held detector to scan the surgical field, ensuring open space for surgery while measuring annihilation radiation with a fixed detector array placed below the patient. We developed a prototype device using two detectors: the hand-held detector and a fixed detector, to demonstrate the feasibility of the proposed concept. Both detectors consisted of 16 × 16 arrays of lutetium yttrium orthosilicates (3 × 3 × 15 mm<sup>3</sup>) coupled one-to-one with 16 × 16 silicon photomultiplier arrays. The position and orientation of the hand-held detector are tracked using an optical tracking sensor that detects attached markers. We measured a <sup>22</sup>Na multi-rod phantom and two <sup>22</sup>Na point sources separately for 180 s while moving the hand-held detector. The rod diameters were 6.0, 5.0, 4.0, 3.0, 2.2, and 1.6 mm. Each point source was placed at the field-of-view center and 35 mm off-center which was outside the sensitive area when the hand-held detector was positioned facing the fixed detector. The 2.2 mm rods were partially resolved, and both point sources were successfully visualized. The potential of the proposed device to visualize small tumors was validated.</p>","PeriodicalId":46252,"journal":{"name":"Radiological Physics and Technology","volume":" ","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2025-03-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiological Physics and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s12194-025-00889-z","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Positron emission tomography (PET) is a valuable tool for diagnosing malignant tumors. Intraoperative PET imaging is expected to allow the more accurate localization of tumors that need resections. However, conventional devices feature a large detector ring that obstructs surgical procedures, preventing their intraoperative application. This paper proposes a new PET device, Scratch-PET, for image-guided tumor resection. The key feature of Scratch-PET is its use of a hand-held detector to scan the surgical field, ensuring open space for surgery while measuring annihilation radiation with a fixed detector array placed below the patient. We developed a prototype device using two detectors: the hand-held detector and a fixed detector, to demonstrate the feasibility of the proposed concept. Both detectors consisted of 16 × 16 arrays of lutetium yttrium orthosilicates (3 × 3 × 15 mm3) coupled one-to-one with 16 × 16 silicon photomultiplier arrays. The position and orientation of the hand-held detector are tracked using an optical tracking sensor that detects attached markers. We measured a 22Na multi-rod phantom and two 22Na point sources separately for 180 s while moving the hand-held detector. The rod diameters were 6.0, 5.0, 4.0, 3.0, 2.2, and 1.6 mm. Each point source was placed at the field-of-view center and 35 mm off-center which was outside the sensitive area when the hand-held detector was positioned facing the fixed detector. The 2.2 mm rods were partially resolved, and both point sources were successfully visualized. The potential of the proposed device to visualize small tumors was validated.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Radiological Physics and Technology
Radiological Physics and Technology RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
3.00
自引率
12.50%
发文量
40
期刊介绍: The purpose of the journal Radiological Physics and Technology is to provide a forum for sharing new knowledge related to research and development in radiological science and technology, including medical physics and radiological technology in diagnostic radiology, nuclear medicine, and radiation therapy among many other radiological disciplines, as well as to contribute to progress and improvement in medical practice and patient health care.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信