Validation of an In Situ Self-Administered Hearing Test with a Self-Fitting Device for Mild to Moderately Severe Hearing Loss in Various Acoustic Environments.

IF 1.3 4区 医学 Q3 OTORHINOLARYNGOLOGY
Tun-Shin Lo, Hung-Yue Chang
{"title":"Validation of an In Situ Self-Administered Hearing Test with a Self-Fitting Device for Mild to Moderately Severe Hearing Loss in Various Acoustic Environments.","authors":"Tun-Shin Lo, Hung-Yue Chang","doi":"10.1177/00034894251325617","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>This study compared a simplified in situ self-administered hearing screening test, conducted with a neckband-type self-fitting device, with conventional pure-tone audiometry. It evaluated the maximum speech-shaped noise level for screening (MSNLS), crucial for evaluating the feasibility of this in situ screening test in quiet environments.</p><p><strong>Methods: </strong>This study included 30 adults with normal hearing and 30 adults with mild to moderately severe hearing impairment. A binaural neckband-type self-fitting device was developed. The results of an in situ hearing screening test conducted using the self-fitting device were compared with those obtained using traditional pure-tone audiometry conducted using TDH-50 earphones. Subsequently, MSNLS was determined by assessing noise-masking effects on screening outcomes. All tests were conducted in an audiometric booth, with the hearing screening test conducted in the booth with the door open.</p><p><strong>Results: </strong>Strong positive correlations were observed between the results of pure-tone audiometry and those of hearing screening tests across all test frequencies, with the strongest correlation observed at 2000 Hz (<i>r<sub>s</sub></i> = 0.793, <i>P</i> < .001) and the weakest correlation observed at 500 Hz (<i>r<sub>s</sub></i> = 0.625, <i>P</i> < .001). Comparisons of screening tests results with pure-tone thresholds across all test frequencies revealed differences of approximately 10 dB HL for 80% of all ears. The sensitivity and specificity of the hearing screening test in detecting candidates with hearing loss (>30 dB HL) who are suitable for this device were 93% and 90%, respectively. The hearing-impaired group exhibited MSNLSs, such as 57 dB SPL at 500 Hz, exceeding ambient noise levels in an empty classroom.</p><p><strong>Conclusion: </strong>The in situ hearing screening test, conducted using a self-fitting device, exhibited reasonable accuracy for self-fitting scenarios in general quiet environments. This test can be used for monitoring mild to moderate hearing loss or fluctuating hearing loss, such as that associated with Ménière's disease.</p>","PeriodicalId":50975,"journal":{"name":"Annals of Otology Rhinology and Laryngology","volume":" ","pages":"34894251325617"},"PeriodicalIF":1.3000,"publicationDate":"2025-03-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Otology Rhinology and Laryngology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/00034894251325617","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: This study compared a simplified in situ self-administered hearing screening test, conducted with a neckband-type self-fitting device, with conventional pure-tone audiometry. It evaluated the maximum speech-shaped noise level for screening (MSNLS), crucial for evaluating the feasibility of this in situ screening test in quiet environments.

Methods: This study included 30 adults with normal hearing and 30 adults with mild to moderately severe hearing impairment. A binaural neckband-type self-fitting device was developed. The results of an in situ hearing screening test conducted using the self-fitting device were compared with those obtained using traditional pure-tone audiometry conducted using TDH-50 earphones. Subsequently, MSNLS was determined by assessing noise-masking effects on screening outcomes. All tests were conducted in an audiometric booth, with the hearing screening test conducted in the booth with the door open.

Results: Strong positive correlations were observed between the results of pure-tone audiometry and those of hearing screening tests across all test frequencies, with the strongest correlation observed at 2000 Hz (rs = 0.793, P < .001) and the weakest correlation observed at 500 Hz (rs = 0.625, P < .001). Comparisons of screening tests results with pure-tone thresholds across all test frequencies revealed differences of approximately 10 dB HL for 80% of all ears. The sensitivity and specificity of the hearing screening test in detecting candidates with hearing loss (>30 dB HL) who are suitable for this device were 93% and 90%, respectively. The hearing-impaired group exhibited MSNLSs, such as 57 dB SPL at 500 Hz, exceeding ambient noise levels in an empty classroom.

Conclusion: The in situ hearing screening test, conducted using a self-fitting device, exhibited reasonable accuracy for self-fitting scenarios in general quiet environments. This test can be used for monitoring mild to moderate hearing loss or fluctuating hearing loss, such as that associated with Ménière's disease.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.10
自引率
7.10%
发文量
171
审稿时长
4-8 weeks
期刊介绍: The Annals of Otology, Rhinology & Laryngology publishes original manuscripts of clinical and research importance in otolaryngology–head and neck medicine and surgery, otology, neurotology, bronchoesophagology, laryngology, rhinology, head and neck oncology and surgery, plastic and reconstructive surgery, pediatric otolaryngology, audiology, and speech pathology. In-depth studies (supplements), papers of historical interest, and reviews of computer software and applications in otolaryngology are also published, as well as imaging, pathology, and clinicopathology studies, book reviews, and letters to the editor. AOR is the official journal of the American Broncho-Esophagological Association.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信