To drain or not to drain in minimal invasive ventral hernia surgery.

IF 2.1 3区 医学 Q2 SURGERY
Stella Wilters, Fadl Alfarawan, Catharina Fahrenkrog, Maximilian Bockhorn, Nader El-Sourani
{"title":"To drain or not to drain in minimal invasive ventral hernia surgery.","authors":"Stella Wilters, Fadl Alfarawan, Catharina Fahrenkrog, Maximilian Bockhorn, Nader El-Sourani","doi":"10.1007/s00423-025-03668-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Despite the high prevalence of ventral hernias worldwide, intraoperative drain placement remains a controversial topic. The benefit in reducing postoperative complications has not yet been clearly demonstrated. This study investigates whether a drain prevents postoperative complications after minimally invasive ventral hernia repair using the extended-totally-extraperitoneal-(eTEP)-technique.</p><p><strong>Methods: </strong>This monocentric, retrospective cohort study included all patients who underwent eTEP between 2019 and 2024. Two comparison groups were formed (54 patients with drain,106 patients without) and analysed for potential differences.</p><p><strong>Results: </strong>There were no significant sociodemographic or clinical differences between the study groups. The defect size was larger in the drain group (drain: 13 cm<sup>2</sup> (64,5) †, no-drain: 6,5 cm<sup>2</sup> (21) †, p = 0,025). There were no significant differences regarding frequency of postoperative complications (drain: 13%, no-drain: 8,5%, p = 0,373), surgical site infections (SSI) (drain: 0%, no-Drain: 1,9%, p = 0,550), and surgical site occurrences (SSO) (drain: 13%, no-Drain: 4,7%, p = 0,108). A subgroup analysis showed that robotically operated patients were more frequently provided with drains (rob: 30 (47,6%), lap: 24 (24,7%), p = 0,003), had larger defect sizes (rob: 28 cm<sup>2</sup> (72)†, lap: 6 cm<sup>2</sup> (9,87)†, p < 0,001), and received Transversus-abdominis-releases (TAR) more often (rob: 14 (22,2%), lap: 5 (5,2%), p = 0,001).</p><p><strong>Conclusion: </strong>We found no significant differences between patients with and without drains after eTEP regarding the frequency of postoperative complications, SSOs and SSIs. Our findings do not suggest nor refute that wound drains prevent postoperative complications.</p>","PeriodicalId":17983,"journal":{"name":"Langenbeck's Archives of Surgery","volume":"410 1","pages":"97"},"PeriodicalIF":2.1000,"publicationDate":"2025-03-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Langenbeck's Archives of Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00423-025-03668-x","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Despite the high prevalence of ventral hernias worldwide, intraoperative drain placement remains a controversial topic. The benefit in reducing postoperative complications has not yet been clearly demonstrated. This study investigates whether a drain prevents postoperative complications after minimally invasive ventral hernia repair using the extended-totally-extraperitoneal-(eTEP)-technique.

Methods: This monocentric, retrospective cohort study included all patients who underwent eTEP between 2019 and 2024. Two comparison groups were formed (54 patients with drain,106 patients without) and analysed for potential differences.

Results: There were no significant sociodemographic or clinical differences between the study groups. The defect size was larger in the drain group (drain: 13 cm2 (64,5) †, no-drain: 6,5 cm2 (21) †, p = 0,025). There were no significant differences regarding frequency of postoperative complications (drain: 13%, no-drain: 8,5%, p = 0,373), surgical site infections (SSI) (drain: 0%, no-Drain: 1,9%, p = 0,550), and surgical site occurrences (SSO) (drain: 13%, no-Drain: 4,7%, p = 0,108). A subgroup analysis showed that robotically operated patients were more frequently provided with drains (rob: 30 (47,6%), lap: 24 (24,7%), p = 0,003), had larger defect sizes (rob: 28 cm2 (72)†, lap: 6 cm2 (9,87)†, p < 0,001), and received Transversus-abdominis-releases (TAR) more often (rob: 14 (22,2%), lap: 5 (5,2%), p = 0,001).

Conclusion: We found no significant differences between patients with and without drains after eTEP regarding the frequency of postoperative complications, SSOs and SSIs. Our findings do not suggest nor refute that wound drains prevent postoperative complications.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.30
自引率
8.70%
发文量
342
审稿时长
4-8 weeks
期刊介绍: Langenbeck''s Archives of Surgery aims to publish the best results in the field of clinical surgery and basic surgical research. The main focus is on providing the highest level of clinical research and clinically relevant basic research. The journal, published exclusively in English, will provide an international discussion forum for the controlled results of clinical surgery. The majority of published contributions will be original articles reporting on clinical data from general and visceral surgery, while endocrine surgery will also be covered. Papers on basic surgical principles from the fields of traumatology, vascular and thoracic surgery are also welcome. Evidence-based medicine is an important criterion for the acceptance of papers.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信