Bone mineral density and hydroxyapatite alignment in leg cortical bone influence on ultrasound velocity.

IF 1.2 Q3 ACOUSTICS
Shuta Kodama, Hiroshi Mita, Norihisa Tamura, Daisuke Koyama, Mami Matsukawa
{"title":"Bone mineral density and hydroxyapatite alignment in leg cortical bone influence on ultrasound velocity.","authors":"Shuta Kodama, Hiroshi Mita, Norihisa Tamura, Daisuke Koyama, Mami Matsukawa","doi":"10.1121/10.0036082","DOIUrl":null,"url":null,"abstract":"<p><p>Bone diagnosis using x-ray techniques, such as computed tomography and dual-energy x-ray absorptiometry, can evaluate bone mineral density (BMD) and microstructure but does not provide elastic properties. This study investigated the ultrasonic properties of racehorse leg cortical bone, focusing on the relationship between wave velocity, BMD, and hydroxyapatite (HAp) crystallite alignment. The results showed a strong correlation between wave velocity and BMD, suggesting that quantitative ultrasound-obtained wave velocity is primarily influenced by BMD, followed by the HAp alignment direction.</p>","PeriodicalId":73538,"journal":{"name":"JASA express letters","volume":"5 3","pages":""},"PeriodicalIF":1.2000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JASA express letters","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1121/10.0036082","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0

Abstract

Bone diagnosis using x-ray techniques, such as computed tomography and dual-energy x-ray absorptiometry, can evaluate bone mineral density (BMD) and microstructure but does not provide elastic properties. This study investigated the ultrasonic properties of racehorse leg cortical bone, focusing on the relationship between wave velocity, BMD, and hydroxyapatite (HAp) crystallite alignment. The results showed a strong correlation between wave velocity and BMD, suggesting that quantitative ultrasound-obtained wave velocity is primarily influenced by BMD, followed by the HAp alignment direction.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.70
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信