Deep learning-based prediction of Monte Carlo dose distribution for heavy ion therapy

IF 3.4 Q2 ONCOLOGY
Rui He , Hui Zhang , Jian Wang , Guosheng Shen , Ying Luo , Xinyang Zhang , Yuanyuan Ma , Xinguo Liu , Yazhou Li , Haibo Peng , Pengbo He , Qiang Li
{"title":"Deep learning-based prediction of Monte Carlo dose distribution for heavy ion therapy","authors":"Rui He ,&nbsp;Hui Zhang ,&nbsp;Jian Wang ,&nbsp;Guosheng Shen ,&nbsp;Ying Luo ,&nbsp;Xinyang Zhang ,&nbsp;Yuanyuan Ma ,&nbsp;Xinguo Liu ,&nbsp;Yazhou Li ,&nbsp;Haibo Peng ,&nbsp;Pengbo He ,&nbsp;Qiang Li","doi":"10.1016/j.phro.2025.100735","DOIUrl":null,"url":null,"abstract":"<div><h3>Background and purpose</h3><div>Current methods, like treatment planning system algorithms (TPSDose), lack accuracy, whereas Monte Carlo dose distribution (MCDose) is accurate but computationally intensive. We proposed a deep learning (DL) model for rapid prediction of Monte Carlo simulated dose distribution (MCDose) in heavy ion therapy (HIT).</div></div><div><h3>Materials and methods</h3><div>We developed a DL model − the Cascade Hierarchically Densely 3D U-Net (CHD U-Net) − to predict MCDose using computed tomography images and TPSDose of 67 head-and-neck patients and 30 thorax-and-abdomen patients. We also compared the results with other proton dose DL models and TPSDose.</div></div><div><h3>Results</h3><div>Compared to TPSDose, the gamma passing rate (GPR) improved by 16 % (1 %/1 mm). Notably, the model achieved 99 % and 97 % accuracy under clinically relevant criteria (3 %/3 mm) across the whole dose distribution in patients. For head-and-neck patients, the GPRs of the C3D and HD U-Net models in the PTV region were 97 % and 85 %, and in the body were 98 % and 97 %, respectively. For thorax-and-abdomen patients, the GPR of the C3D and HD U-Net models in the PTV region were 71 % and 51 %, and in the body were 95 % and 90 %, respectively.</div></div><div><h3>Conclusions</h3><div>The proposed CHD U-Net model can predict MCDose in a few seconds and outperforms two alternative DL models. The predicted dose can replace TPSDose in HIT clinical process due to its MC simulation accuracy, thus improving the accuracy of dose calculation and providing a valuable reference for quality assurance.</div></div>","PeriodicalId":36850,"journal":{"name":"Physics and Imaging in Radiation Oncology","volume":"34 ","pages":"Article 100735"},"PeriodicalIF":3.4000,"publicationDate":"2025-03-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physics and Imaging in Radiation Oncology","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2405631625000405","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background and purpose

Current methods, like treatment planning system algorithms (TPSDose), lack accuracy, whereas Monte Carlo dose distribution (MCDose) is accurate but computationally intensive. We proposed a deep learning (DL) model for rapid prediction of Monte Carlo simulated dose distribution (MCDose) in heavy ion therapy (HIT).

Materials and methods

We developed a DL model − the Cascade Hierarchically Densely 3D U-Net (CHD U-Net) − to predict MCDose using computed tomography images and TPSDose of 67 head-and-neck patients and 30 thorax-and-abdomen patients. We also compared the results with other proton dose DL models and TPSDose.

Results

Compared to TPSDose, the gamma passing rate (GPR) improved by 16 % (1 %/1 mm). Notably, the model achieved 99 % and 97 % accuracy under clinically relevant criteria (3 %/3 mm) across the whole dose distribution in patients. For head-and-neck patients, the GPRs of the C3D and HD U-Net models in the PTV region were 97 % and 85 %, and in the body were 98 % and 97 %, respectively. For thorax-and-abdomen patients, the GPR of the C3D and HD U-Net models in the PTV region were 71 % and 51 %, and in the body were 95 % and 90 %, respectively.

Conclusions

The proposed CHD U-Net model can predict MCDose in a few seconds and outperforms two alternative DL models. The predicted dose can replace TPSDose in HIT clinical process due to its MC simulation accuracy, thus improving the accuracy of dose calculation and providing a valuable reference for quality assurance.
求助全文
约1分钟内获得全文 求助全文
来源期刊
Physics and Imaging in Radiation Oncology
Physics and Imaging in Radiation Oncology Physics and Astronomy-Radiation
CiteScore
5.30
自引率
18.90%
发文量
93
审稿时长
6 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信