Quantification of Metamorphopsia using a Smartphone-based Hyperacuity Test in Patients with Idiopathic Epiretinal Membranes: Prospective Observational Study.

Daria Amon, Chritstoph Leisser, Andreas Schlatter, Manuel Ruiss, Caroline Pilwachs, Natascha Bayer, Josef Huemer, Oliver Findl
{"title":"Quantification of Metamorphopsia using a Smartphone-based Hyperacuity Test in Patients with Idiopathic Epiretinal Membranes: Prospective Observational Study.","authors":"Daria Amon, Chritstoph Leisser, Andreas Schlatter, Manuel Ruiss, Caroline Pilwachs, Natascha Bayer, Josef Huemer, Oliver Findl","doi":"10.2196/60959","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Quality of vision in patients with idiopathic epiretinal membranes (iERM) is closely linked to distorted vision (metamorphopsia), which is often underestimated in clinical settings. Current surgical decision-making relies heavily on visual acuity and OCT findings, which do not adequately reflect the patient's functional vision or the severity of metamorphopsia. There is a clinical need for tools that can reliably quantify this symptom to improve patient outcomes and streamline care pathways.</p><p><strong>Objective: </strong>This study is the first to assess the utility of a novel smartphone-based hyperacuity test (SHT) in quantifying metamorphopsia before and after surgical intervention for iERM, comparing it to a conventional printed chart.</p><p><strong>Methods: </strong>This prospective observational study included 27 iERM patients with symptomatic metamorphopsia detected on the Amsler grid scheduled for vitrectomy with membrane peeling. The SHT (Alleye, Oculocare medical Inc., Zurich, Switzerland) and the horizontal (MH) and vertical (MV) M-chart (Inami & Co., Ltd., Tokyo, Japan) tests were performed three times before and three months after surgery. Pre- and postoperative metamorphopsia scores, changes in distance-corrected visual acuity (DCVA), optical coherence tomography (OCT) biomarkers and subjective perception of metamorphopsia were evaluated.</p><p><strong>Results: </strong>The mean SHT score significantly (r=.686, P<.001) improved from 55.2 ± 18.9 before surgery to 63.5 ± 16.3 after surgery while the improvement of the M-chart scores were insignificant (MH r=.37, P=.06; MV r=.18, P=.36). Pre- and postoperative SHT scores showed very weak and insignificant correlations with the MH, MV, and MH+MV scores. Both metamorphopsia tests showed good reliability (intraclass correlation coefficients >0.75).</p><p><strong>Conclusions: </strong>The smartphone-based hyperacuity test (SHT) showed a significant improvement in postoperative metamorphopsia scores, indicating that it could be a valuable tool for quantifying visual distortion in iERM patients. While discrepancies with M-chart results were observed, both tests demonstrated good reliability. Clinically, the SHT may offer a practical solution for monitoring metamorphopsia and guiding complex surgical decision-making, particularly in telemedicine settings. Its accessibility could improve patient management, potentially enhancing pre-operative triaging and reducing unnecessary visits.</p><p><strong>Clinicaltrial: </strong>ClinicalTrials.gov NCT05138315.</p>","PeriodicalId":73557,"journal":{"name":"JMIR perioperative medicine","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-03-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JMIR perioperative medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2196/60959","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Quality of vision in patients with idiopathic epiretinal membranes (iERM) is closely linked to distorted vision (metamorphopsia), which is often underestimated in clinical settings. Current surgical decision-making relies heavily on visual acuity and OCT findings, which do not adequately reflect the patient's functional vision or the severity of metamorphopsia. There is a clinical need for tools that can reliably quantify this symptom to improve patient outcomes and streamline care pathways.

Objective: This study is the first to assess the utility of a novel smartphone-based hyperacuity test (SHT) in quantifying metamorphopsia before and after surgical intervention for iERM, comparing it to a conventional printed chart.

Methods: This prospective observational study included 27 iERM patients with symptomatic metamorphopsia detected on the Amsler grid scheduled for vitrectomy with membrane peeling. The SHT (Alleye, Oculocare medical Inc., Zurich, Switzerland) and the horizontal (MH) and vertical (MV) M-chart (Inami & Co., Ltd., Tokyo, Japan) tests were performed three times before and three months after surgery. Pre- and postoperative metamorphopsia scores, changes in distance-corrected visual acuity (DCVA), optical coherence tomography (OCT) biomarkers and subjective perception of metamorphopsia were evaluated.

Results: The mean SHT score significantly (r=.686, P<.001) improved from 55.2 ± 18.9 before surgery to 63.5 ± 16.3 after surgery while the improvement of the M-chart scores were insignificant (MH r=.37, P=.06; MV r=.18, P=.36). Pre- and postoperative SHT scores showed very weak and insignificant correlations with the MH, MV, and MH+MV scores. Both metamorphopsia tests showed good reliability (intraclass correlation coefficients >0.75).

Conclusions: The smartphone-based hyperacuity test (SHT) showed a significant improvement in postoperative metamorphopsia scores, indicating that it could be a valuable tool for quantifying visual distortion in iERM patients. While discrepancies with M-chart results were observed, both tests demonstrated good reliability. Clinically, the SHT may offer a practical solution for monitoring metamorphopsia and guiding complex surgical decision-making, particularly in telemedicine settings. Its accessibility could improve patient management, potentially enhancing pre-operative triaging and reducing unnecessary visits.

Clinicaltrial: ClinicalTrials.gov NCT05138315.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.50
自引率
0.00%
发文量
0
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信