Importance of Raw-Data Analysis When Determining the Cause of Pause Alerts Transmitted by an Implantable Loop Recorder Remote Monitoring Devices.

IF 2.3 3区 医学 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS
Moshe Rav Acha, Hana Raiz, Michael Glikson, Michael Ilan
{"title":"Importance of Raw-Data Analysis When Determining the Cause of Pause Alerts Transmitted by an Implantable Loop Recorder Remote Monitoring Devices.","authors":"Moshe Rav Acha, Hana Raiz, Michael Glikson, Michael Ilan","doi":"10.1111/jce.16634","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Use of implantable loop recorder (ILR) for the diagnosis and documentation of cardiac arrhythmia has gained popularity during the last decade. Most ILRs are accompanied by remote monitoring (RM) devices, which allow automated daily interrogations of the ILR. These transmit arrhythmic or pause alerts to the treating clinic, enabling timely medical attention and treatment. Although ILR RM transmissions have been shown to have significant false positive alerts, a true positive alert suggesting a wrong arrhythmia diagnosis has not been shown to date.</p><p><strong>Methods and results: </strong>We revised all ILR pause transmissions arriving to our hospital device clinic during 2024, looking for pause alerts which were initially misdiagnosed. We report a case series of patients in whom a RM pause alert has been transmitted with a suspected apparent diagnosis of sinus arrest. However, when interrogating the ILR in clinic, these episodes were diagnosed as high-degree atrioventricular block (AVB) pauses, for which an urgent permanent pacemaker (PPM) might be indicated. Review of these cases revealed that in contrast with the automated RM PDF alerts, in which the figure resolution cannot be changed (and thus small P waves may be unnoticed), the raw-data episode recording on the RM web page enables one to increase the image resolution to clearly discern initially unnoticed non-conducted P waves.</p><p><strong>Conclusion: </strong>ILR RM pause alerts should always be reviewed via the raw-data RM web page or alternatively via ILR device interrogations, to achieve a sufficiently high-resolution image to assure these pauses are not due to AVB.</p>","PeriodicalId":15178,"journal":{"name":"Journal of Cardiovascular Electrophysiology","volume":" ","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2025-03-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular Electrophysiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/jce.16634","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Use of implantable loop recorder (ILR) for the diagnosis and documentation of cardiac arrhythmia has gained popularity during the last decade. Most ILRs are accompanied by remote monitoring (RM) devices, which allow automated daily interrogations of the ILR. These transmit arrhythmic or pause alerts to the treating clinic, enabling timely medical attention and treatment. Although ILR RM transmissions have been shown to have significant false positive alerts, a true positive alert suggesting a wrong arrhythmia diagnosis has not been shown to date.

Methods and results: We revised all ILR pause transmissions arriving to our hospital device clinic during 2024, looking for pause alerts which were initially misdiagnosed. We report a case series of patients in whom a RM pause alert has been transmitted with a suspected apparent diagnosis of sinus arrest. However, when interrogating the ILR in clinic, these episodes were diagnosed as high-degree atrioventricular block (AVB) pauses, for which an urgent permanent pacemaker (PPM) might be indicated. Review of these cases revealed that in contrast with the automated RM PDF alerts, in which the figure resolution cannot be changed (and thus small P waves may be unnoticed), the raw-data episode recording on the RM web page enables one to increase the image resolution to clearly discern initially unnoticed non-conducted P waves.

Conclusion: ILR RM pause alerts should always be reviewed via the raw-data RM web page or alternatively via ILR device interrogations, to achieve a sufficiently high-resolution image to assure these pauses are not due to AVB.

在确定由植入式循环记录器远程监控设备传输的暂停警报原因时,原始数据分析的重要性。
简介:在过去的十年中,使用植入式循环记录仪(ILR)诊断和记录心律失常已经得到了普及。大多数ILR都配有远程监控(RM)设备,可以对ILR进行日常自动询问。这些设备向治疗诊所发送心律失常或暂停警报,从而实现及时的医疗护理和治疗。虽然ILR RM传输已被证明有明显的假阳性警报,但迄今为止尚未显示出提示错误心律失常诊断的真阳性警报。方法和结果:我们修改了2024年期间到达我们医院设备诊所的所有ILR暂停传输,寻找最初被误诊的暂停警报。我们报告一个病例系列的患者,其中RM暂停警报已传播与疑似窦骤停的明显诊断。然而,当在临床上询问ILR时,这些发作被诊断为高度房室传导阻滞(AVB)暂停,可能需要紧急永久性起搏器(PPM)。对这些病例的回顾显示,与自动RM PDF警报相反,其中图像分辨率不能改变(因此小的P波可能被忽略),RM网页上的原始数据片段记录使人们能够提高图像分辨率,以清楚地识别最初未被注意到的非导P波。结论:ILR RM暂停警报应始终通过原始数据RM网页或通过ILR设备询问进行审查,以获得足够高分辨率的图像,以确保这些暂停不是由于AVB。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.20
自引率
14.80%
发文量
433
审稿时长
3-6 weeks
期刊介绍: Journal of Cardiovascular Electrophysiology (JCE) keeps its readership well informed of the latest developments in the study and management of arrhythmic disorders. Edited by Bradley P. Knight, M.D., and a distinguished international editorial board, JCE is the leading journal devoted to the study of the electrophysiology of the heart.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信