Kaige Li, Yangbin Shi, Xinhua Wang, Ping Ye, Bing Han, Weifeng Jiang, Yu Zhang, Qidong Zheng, Anjing Ji, Menghe Zhang, Yanzhe Wang, Shaohui Wu, Kai Xu, Mu Qin, Xu Liu, Xumin Hou
{"title":"Aggressive ablation vs. regular ablation for persistent atrial fibrillation: a multicentre real-world cohort study.","authors":"Kaige Li, Yangbin Shi, Xinhua Wang, Ping Ye, Bing Han, Weifeng Jiang, Yu Zhang, Qidong Zheng, Anjing Ji, Menghe Zhang, Yanzhe Wang, Shaohui Wu, Kai Xu, Mu Qin, Xu Liu, Xumin Hou","doi":"10.1093/europace/euaf045","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>Current guidelines for the optimal ablation strategy for persistent atrial fibrillation (PerAF) remain unclear. While our previous RCT confirmed the favourable prognosis of aggressive ablation, real-world evidence is still lacking.</p><p><strong>Methods and results: </strong>Among 4833 PerAF patients undergoing catheter ablation at 10 centres, two groups were defined: regular ablation (PVI-only or PVI plus anatomical ablation) and aggressive ablation (anatomical plus electrogram-guided ablation), with 1560 patients each after propensity score (PS) matching. The primary endpoint was 12-month AF/atrial tachycardia (AT) recurrence-free survival off anti-arrhythmic drugs after a single procedure. Additional PS matching was performed within the regular group between PVI-only and anatomical ablation (n = 455 each). Furthermore, anatomical ablation from the regular group was independently matched with aggressive ablation (n = 1362 each). At 12 months, the aggressive group showed superior AF/AT-free survival (66.2% vs. 59.3%, P < 0.001; HR 0.745), similar AT recurrence (12.0% vs. 11.3%, P = 0.539), and significantly higher procedural AF termination (67.0% vs. 21.0%, P < 0.001) than regular group. Moreover, patients with AF termination had improved AF/AT-free survival (72.3% vs. 55.2%, P < 0.001). Safety endpoints did not differ significantly between the two groups. Both the ablation outcomes and AF termination rate showed increasing trends with the extent of ablation aggressiveness but declined with extremely aggressive ablation. After additional PS matching, within the regular group, no statistical differences were observed though AF/AT-free survival in the anatomical group was slightly higher than the PVI-only group (60.7% vs. 55.6%, P = 0.122); while aggressive ablation showed improved AF/AT-free survival compared to anatomical ablation alone from regular group (67.5% vs. 59.9%, P < 0.001).</p><p><strong>Conclusion: </strong>Aggressive ablation achieved more favourable outcomes than regular ablation, and moderately aggressive ablation may be associated with better clinical outcomes. AF termination is a reliable ablation endpoint.</p>","PeriodicalId":11981,"journal":{"name":"Europace","volume":" ","pages":""},"PeriodicalIF":7.9000,"publicationDate":"2025-03-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11920505/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Europace","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/europace/euaf045","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Aims: Current guidelines for the optimal ablation strategy for persistent atrial fibrillation (PerAF) remain unclear. While our previous RCT confirmed the favourable prognosis of aggressive ablation, real-world evidence is still lacking.
Methods and results: Among 4833 PerAF patients undergoing catheter ablation at 10 centres, two groups were defined: regular ablation (PVI-only or PVI plus anatomical ablation) and aggressive ablation (anatomical plus electrogram-guided ablation), with 1560 patients each after propensity score (PS) matching. The primary endpoint was 12-month AF/atrial tachycardia (AT) recurrence-free survival off anti-arrhythmic drugs after a single procedure. Additional PS matching was performed within the regular group between PVI-only and anatomical ablation (n = 455 each). Furthermore, anatomical ablation from the regular group was independently matched with aggressive ablation (n = 1362 each). At 12 months, the aggressive group showed superior AF/AT-free survival (66.2% vs. 59.3%, P < 0.001; HR 0.745), similar AT recurrence (12.0% vs. 11.3%, P = 0.539), and significantly higher procedural AF termination (67.0% vs. 21.0%, P < 0.001) than regular group. Moreover, patients with AF termination had improved AF/AT-free survival (72.3% vs. 55.2%, P < 0.001). Safety endpoints did not differ significantly between the two groups. Both the ablation outcomes and AF termination rate showed increasing trends with the extent of ablation aggressiveness but declined with extremely aggressive ablation. After additional PS matching, within the regular group, no statistical differences were observed though AF/AT-free survival in the anatomical group was slightly higher than the PVI-only group (60.7% vs. 55.6%, P = 0.122); while aggressive ablation showed improved AF/AT-free survival compared to anatomical ablation alone from regular group (67.5% vs. 59.9%, P < 0.001).
Conclusion: Aggressive ablation achieved more favourable outcomes than regular ablation, and moderately aggressive ablation may be associated with better clinical outcomes. AF termination is a reliable ablation endpoint.
期刊介绍:
EP - Europace - European Journal of Pacing, Arrhythmias and Cardiac Electrophysiology of the European Heart Rhythm Association of the European Society of Cardiology. The journal aims to provide an avenue of communication of top quality European and international original scientific work and reviews in the fields of Arrhythmias, Pacing and Cellular Electrophysiology. The Journal offers the reader a collection of contemporary original peer-reviewed papers, invited papers and editorial comments together with book reviews and correspondence.