{"title":"Threshold size criterion to suspect malignant supraclavicular lymph node < 10 mm in esophageal cancer.","authors":"Yue Huang, Jingsai Du, Qian Li, Tiantian Fan, Zhaoqi Wang, Funing Chu, Jing Li, Bing Li, Xiong Yang, Renzhi Zhang, Ihab R Kamel, Yang Zhou, Zhen Li, Jinrong Qu","doi":"10.1186/s13244-025-01929-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To determine the threshold size for predicting metastasis of supraclavicular lymph nodes (SCLNs) < 10 mm on axial and multiplanar reconstruction CT in esophageal squamous cell carcinoma (ESCC).</p><p><strong>Methods: </strong>This retrospective, multicenter study received approval from three institutional review boards, which waived informed consent. Patients with ESCC had ultrasound-guided fine-needle aspiration biopsy (US-FNAB) for SCLNs, with contrast-enhanced CT performed within 2 weeks prior to US-FNAB. A CT and ultrasound radiologist jointly analyzed images to identify and mark biopsied SCLNs < 10 mm on CT, followed by two blinded radiologists who independently measured short-axis diameter (SAD), long-axis diameter (LAD), short diameter of multiplanar reconstruction (SD-MPR), long diameter of multiplanar reconstruction (LD-MPR) and the intra-class correlation coefficient (ICC) was analyzed. Center 1 included 220 SCLNs as the training set, and Centers 2 + 3 included 75 SCLNs as the validation set. The optimal cutoff value was determined using receiver operating characteristic (ROC) curves.</p><p><strong>Results: </strong>In the training and validation sets, 31.8% (70/220) and 32.0% (24/75) of SCLNs were positive. ICC for SAD was excellent (ICC = 0.847). The area under the receiver operating characteristic curve of SAD was 0.832 in the training set, higher than others, with a cutoff value of > 6 mm, resulting in sensitivity, specificity, positive predictive value, negative predictive value, accuracy of 77.1%, 80.7%, 65.0%, 88.3%, 79.1%, respectively. In the validation set, these metrics were 87.5%, 74.5%, 61.8%, 92.7%, 81.0%, respectively.</p><p><strong>Conclusion: </strong>SAD on CT can suspect metastasis of SCLN < 10 mm in ESCC patients, with a threshold size of > 6 mm.</p><p><strong>Clinical relevance statement: </strong>Determining the threshold size criterion on CT images may enhance the prediction of supraclavicular lymph node metastasis in esophageal squamous cell carcinoma patients, thereby benefiting diagnostic and therapeutic strategies.</p><p><strong>Key points: </strong>Supraclavicular lymph nodes < 10 mm in esophageal carcinoma are indeterminate for malignancy. Supraclavicular lymph nodes > 6 mm are highly suspicious for malignancy. The metastasis status of supraclavicular lymph nodes is critical for staging esophageal carcinoma.</p>","PeriodicalId":13639,"journal":{"name":"Insights into Imaging","volume":"16 1","pages":"50"},"PeriodicalIF":4.1000,"publicationDate":"2025-03-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11883069/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Insights into Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s13244-025-01929-3","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: To determine the threshold size for predicting metastasis of supraclavicular lymph nodes (SCLNs) < 10 mm on axial and multiplanar reconstruction CT in esophageal squamous cell carcinoma (ESCC).

Methods: This retrospective, multicenter study received approval from three institutional review boards, which waived informed consent. Patients with ESCC had ultrasound-guided fine-needle aspiration biopsy (US-FNAB) for SCLNs, with contrast-enhanced CT performed within 2 weeks prior to US-FNAB. A CT and ultrasound radiologist jointly analyzed images to identify and mark biopsied SCLNs < 10 mm on CT, followed by two blinded radiologists who independently measured short-axis diameter (SAD), long-axis diameter (LAD), short diameter of multiplanar reconstruction (SD-MPR), long diameter of multiplanar reconstruction (LD-MPR) and the intra-class correlation coefficient (ICC) was analyzed. Center 1 included 220 SCLNs as the training set, and Centers 2 + 3 included 75 SCLNs as the validation set. The optimal cutoff value was determined using receiver operating characteristic (ROC) curves.

Results: In the training and validation sets, 31.8% (70/220) and 32.0% (24/75) of SCLNs were positive. ICC for SAD was excellent (ICC = 0.847). The area under the receiver operating characteristic curve of SAD was 0.832 in the training set, higher than others, with a cutoff value of > 6 mm, resulting in sensitivity, specificity, positive predictive value, negative predictive value, accuracy of 77.1%, 80.7%, 65.0%, 88.3%, 79.1%, respectively. In the validation set, these metrics were 87.5%, 74.5%, 61.8%, 92.7%, 81.0%, respectively.

Conclusion: SAD on CT can suspect metastasis of SCLN < 10 mm in ESCC patients, with a threshold size of > 6 mm.

Clinical relevance statement: Determining the threshold size criterion on CT images may enhance the prediction of supraclavicular lymph node metastasis in esophageal squamous cell carcinoma patients, thereby benefiting diagnostic and therapeutic strategies.

Key points: Supraclavicular lymph nodes < 10 mm in esophageal carcinoma are indeterminate for malignancy. Supraclavicular lymph nodes > 6 mm are highly suspicious for malignancy. The metastasis status of supraclavicular lymph nodes is critical for staging esophageal carcinoma.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Insights into Imaging
Insights into Imaging Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
7.30
自引率
4.30%
发文量
182
审稿时长
13 weeks
期刊介绍: Insights into Imaging (I³) is a peer-reviewed open access journal published under the brand SpringerOpen. All content published in the journal is freely available online to anyone, anywhere! I³ continuously updates scientific knowledge and progress in best-practice standards in radiology through the publication of original articles and state-of-the-art reviews and opinions, along with recommendations and statements from the leading radiological societies in Europe. Founded by the European Society of Radiology (ESR), I³ creates a platform for educational material, guidelines and recommendations, and a forum for topics of controversy. A balanced combination of review articles, original papers, short communications from European radiological congresses and information on society matters makes I³ an indispensable source for current information in this field. I³ is owned by the ESR, however authors retain copyright to their article according to the Creative Commons Attribution License (see Copyright and License Agreement). All articles can be read, redistributed and reused for free, as long as the author of the original work is cited properly. The open access fees (article-processing charges) for this journal are kindly sponsored by ESR for all Members. The journal went open access in 2012, which means that all articles published since then are freely available online.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信