Initial characterization of a novel dual-robot orthovoltage radiotherapy system.

IF 1.3 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Olivia Masella, Jacob Atkinson, Sandhya Rottoo, Michael Weil, Magdalena Bazalova-Carter
{"title":"Initial characterization of a novel dual-robot orthovoltage radiotherapy system.","authors":"Olivia Masella, Jacob Atkinson, Sandhya Rottoo, Michael Weil, Magdalena Bazalova-Carter","doi":"10.1088/2057-1976/adbcb2","DOIUrl":null,"url":null,"abstract":"<p><p><b>Purpose:</b>Adequate access to radiotherapy is a critical global concern affecting low-resource settings such as low- and middle-income countries and rural regions. We propose to reduce this disparity by developing a novel low-cost radiotherapy device that treats using non-coplanar techniques and a 225 kVp x-ray tube.<b>Methods:</b>This novel device has been preliminarily characterized spectrally, via spectrometer measurements, dosimetrically, via percent depth dose curves and 2D profiles, and geometrically, via a coplanar star-shot. Dosimetric and geometric evaluations were then combined by performing a proof of workflow of the KOALA system. Monte Carlo simulations were run in TOPAS to validate dosimetric measurements and the proof of workflow measurement.<b>Results:</b>Spectral results showed excellent agreement between measured and modelled spectra. Dose errors of  < 2% were achieved for PDD curves. Full width at half maximum values for the 2D profiles were, on average, 0.95 mm higher in simulation compared to film. A star-shot test demonstrated the high geometrical accuracy of the system with a 0.3 mm diameter wobble circle. Finally, a mean absolute percent error of 5  ±  5% (1<i>σ</i>) was measured for the proof of workflow test.<b>Conclusions:</b>This initial characterization showcased the strengths and weaknesses of the KOALA system, with excellent isocenter precision and depth dose accuracy while lacking dosimetric accuracy in the 2D profiles. Further improvements on the source-to-collimator distance and treatment couch material can be made to improve the accuracy of a Monte Carlo model of the KOALA system.</p>","PeriodicalId":8896,"journal":{"name":"Biomedical Physics & Engineering Express","volume":" ","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2025-03-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Physics & Engineering Express","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/2057-1976/adbcb2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose:Adequate access to radiotherapy is a critical global concern affecting low-resource settings such as low- and middle-income countries and rural regions. We propose to reduce this disparity by developing a novel low-cost radiotherapy device that treats using non-coplanar techniques and a 225 kVp x-ray tube.Methods:This novel device has been preliminarily characterized spectrally, via spectrometer measurements, dosimetrically, via percent depth dose curves and 2D profiles, and geometrically, via a coplanar star-shot. Dosimetric and geometric evaluations were then combined by performing a proof of workflow of the KOALA system. Monte Carlo simulations were run in TOPAS to validate dosimetric measurements and the proof of workflow measurement.Results:Spectral results showed excellent agreement between measured and modelled spectra. Dose errors of  < 2% were achieved for PDD curves. Full width at half maximum values for the 2D profiles were, on average, 0.95 mm higher in simulation compared to film. A star-shot test demonstrated the high geometrical accuracy of the system with a 0.3 mm diameter wobble circle. Finally, a mean absolute percent error of 5  ±  5% (1σ) was measured for the proof of workflow test.Conclusions:This initial characterization showcased the strengths and weaknesses of the KOALA system, with excellent isocenter precision and depth dose accuracy while lacking dosimetric accuracy in the 2D profiles. Further improvements on the source-to-collimator distance and treatment couch material can be made to improve the accuracy of a Monte Carlo model of the KOALA system.

一种新型双机器人正电压放疗系统的初步表征。
目的:充分获得放射治疗是影响低资源环境(如中低收入国家和农村地区)的一个重要全球问题。我们建议通过开发一种新型的低成本放疗设备来减少这种差异,该设备使用非共面技术和225 kVp x射线管进行治疗。方法:该新型设备已通过光谱仪测量、剂量学、百分比深度剂量曲线和二维剖面以及共面星射进行了初步的光谱表征。然后通过执行KOALA系统的工作流程证明将剂量学和几何评估结合起来。在TOPAS中运行蒙特卡罗模拟以验证剂量学测量和工作流测量的证明。结果:光谱结果显示测量光谱与模型光谱之间具有良好的一致性。剂量误差
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Biomedical Physics & Engineering Express
Biomedical Physics & Engineering Express RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
2.80
自引率
0.00%
发文量
153
期刊介绍: BPEX is an inclusive, international, multidisciplinary journal devoted to publishing new research on any application of physics and/or engineering in medicine and/or biology. Characterized by a broad geographical coverage and a fast-track peer-review process, relevant topics include all aspects of biophysics, medical physics and biomedical engineering. Papers that are almost entirely clinical or biological in their focus are not suitable. The journal has an emphasis on publishing interdisciplinary work and bringing research fields together, encompassing experimental, theoretical and computational work.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信