RF-induced Heating for Partially-In and Partially-Out Bipolar Parallel Medical Electrodes.

Md Zahidul Islam, Mir Khadiza Akter, Qingyan Wang, Ran Guo, Jianfeng Zheng, Ji Chen
{"title":"RF-induced Heating for Partially-In and Partially-Out Bipolar Parallel Medical Electrodes.","authors":"Md Zahidul Islam, Mir Khadiza Akter, Qingyan Wang, Ran Guo, Jianfeng Zheng, Ji Chen","doi":"10.1109/EMBC53108.2024.10782861","DOIUrl":null,"url":null,"abstract":"<p><p>RF-induced heating is evaluated for unipolar and bipolar Partially-In and Partially-Out (PIPO) medical electrodes at 1.5T MRI. Numerical simulations were performed by modeling simplified unipolar and bipolar electrodes to understand the RF heating mechanism. Then, experimental studies inside the ASTM phantom were performed using a 60 cm long commercial unipolar and bipolar PIPO cardiac pacing electrodes. In addition, transfer function models were developed, scaled, and validated for 60 cm pacing electrodes, and in-vivo heating was estimated for 30-minute RF exposure using the standard medium. The results show that the RF heating for the bipolar PIPO medical electrode is lower than the unipolar PIPO electrode due to coupling between the parallel leads. However, this study uses limited clinical trajectories for the external pacing application; heating could differ for other possible trajectories, devices, or applications.</p>","PeriodicalId":72237,"journal":{"name":"Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference","volume":"2024 ","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EMBC53108.2024.10782861","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

RF-induced heating is evaluated for unipolar and bipolar Partially-In and Partially-Out (PIPO) medical electrodes at 1.5T MRI. Numerical simulations were performed by modeling simplified unipolar and bipolar electrodes to understand the RF heating mechanism. Then, experimental studies inside the ASTM phantom were performed using a 60 cm long commercial unipolar and bipolar PIPO cardiac pacing electrodes. In addition, transfer function models were developed, scaled, and validated for 60 cm pacing electrodes, and in-vivo heating was estimated for 30-minute RF exposure using the standard medium. The results show that the RF heating for the bipolar PIPO medical electrode is lower than the unipolar PIPO electrode due to coupling between the parallel leads. However, this study uses limited clinical trajectories for the external pacing application; heating could differ for other possible trajectories, devices, or applications.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.80
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信