Quantitative Ultrasonic Backscatter Evaluation of Elastic and Mechanical Property in a Rabbit Tendinopathy Healing Model.

IF 4.4 2区 医学 Q2 ENGINEERING, BIOMEDICAL
Qian Zheng, Min He, Mengyao Liu, Shuxin Sun, Chengcheng Liu, Ying Li, Lixin Jiang, Dean Ta
{"title":"Quantitative Ultrasonic Backscatter Evaluation of Elastic and Mechanical Property in a Rabbit Tendinopathy Healing Model.","authors":"Qian Zheng, Min He, Mengyao Liu, Shuxin Sun, Chengcheng Liu, Ying Li, Lixin Jiang, Dean Ta","doi":"10.1109/TBME.2025.3544327","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>This study investigates the feasibility of non-invasive ultrasound backscatter techniques for quantitative tendon characterization.</p><p><strong>Methods: </strong>Sixty-six New Zealand white rabbits were divided into three groups: normal control group (NC group), model control group (MC group), and low-intensity pulsed ultrasound (LIPUS) treatment group (LT group). Tendinopathy models were induced in MC and LT groups, with the LT group receiving LIPUS intervention and the MC group receiving sham ultrasound therapy. The NC group underwent no treatment. Ultrasound backscatter signals were acquired in vitro and in vivo using a 3.5 MHz unfocused transducer at 1, 4, 7, 14, and 28 days post-intervention. Signals of interest (SOI) from the Achilles tendon were extracted based on in vitro monolayer tissue and in vivo multilayer tissue models. The backscatter parameters including average integrated backscatter (AIB), spectral centroid shift (SCS), frequency slope of apparent backscatter (FSAB), and frequency intercept of apparent backscatter (FIAB) were calculated and analyzed to ultrasound elastic and mechanical properties.</p><p><strong>Results: </strong>The results revealed that backscatter parameters were strongly correlated with ultrasonic elastic properties and weakly correlated with mechanical properties, generally exhibiting negative correlations. Notably, AIB demonstrated stable characterization capability for both ultrasonic elastic and mechanical properties (in vitro: r = -0.71 for shear modulus; r = -0.43 for tensile modulus; in vivo: r = -0.70 for shear modulus; r = -0.50 for tensile modulus).</p><p><strong>Conclusion: </strong>This study validates the use of quantitative ultrasound backscatter as a viable technique for assessing tendon properties.</p><p><strong>Significance: </strong>ultrasound backscatter offers potential applications in tendon characterization.</p>","PeriodicalId":13245,"journal":{"name":"IEEE Transactions on Biomedical Engineering","volume":"PP ","pages":""},"PeriodicalIF":4.4000,"publicationDate":"2025-02-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1109/TBME.2025.3544327","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: This study investigates the feasibility of non-invasive ultrasound backscatter techniques for quantitative tendon characterization.

Methods: Sixty-six New Zealand white rabbits were divided into three groups: normal control group (NC group), model control group (MC group), and low-intensity pulsed ultrasound (LIPUS) treatment group (LT group). Tendinopathy models were induced in MC and LT groups, with the LT group receiving LIPUS intervention and the MC group receiving sham ultrasound therapy. The NC group underwent no treatment. Ultrasound backscatter signals were acquired in vitro and in vivo using a 3.5 MHz unfocused transducer at 1, 4, 7, 14, and 28 days post-intervention. Signals of interest (SOI) from the Achilles tendon were extracted based on in vitro monolayer tissue and in vivo multilayer tissue models. The backscatter parameters including average integrated backscatter (AIB), spectral centroid shift (SCS), frequency slope of apparent backscatter (FSAB), and frequency intercept of apparent backscatter (FIAB) were calculated and analyzed to ultrasound elastic and mechanical properties.

Results: The results revealed that backscatter parameters were strongly correlated with ultrasonic elastic properties and weakly correlated with mechanical properties, generally exhibiting negative correlations. Notably, AIB demonstrated stable characterization capability for both ultrasonic elastic and mechanical properties (in vitro: r = -0.71 for shear modulus; r = -0.43 for tensile modulus; in vivo: r = -0.70 for shear modulus; r = -0.50 for tensile modulus).

Conclusion: This study validates the use of quantitative ultrasound backscatter as a viable technique for assessing tendon properties.

Significance: ultrasound backscatter offers potential applications in tendon characterization.

求助全文
约1分钟内获得全文 求助全文
来源期刊
IEEE Transactions on Biomedical Engineering
IEEE Transactions on Biomedical Engineering 工程技术-工程:生物医学
CiteScore
9.40
自引率
4.30%
发文量
880
审稿时长
2.5 months
期刊介绍: IEEE Transactions on Biomedical Engineering contains basic and applied papers dealing with biomedical engineering. Papers range from engineering development in methods and techniques with biomedical applications to experimental and clinical investigations with engineering contributions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信