Continuous Glucose Monitoring-Based Titration of Once-Weekly Insulin Icodec in Insulin-Naive Individuals with Type 2 Diabetes (ONWARDS 9): A Phase 3b, Multicenter, Single-Arm, Treat-to-Target Clinical Trial.
Richard M Bergenstal, Björg Ásbjörnsdóttir, Tanvir Johanning Bari, Satish Hulkund, Yvonne Winhofer, Carol Wysham
{"title":"Continuous Glucose Monitoring-Based Titration of Once-Weekly Insulin Icodec in Insulin-Naive Individuals with Type 2 Diabetes (ONWARDS 9): A Phase 3b, Multicenter, Single-Arm, Treat-to-Target Clinical Trial.","authors":"Richard M Bergenstal, Björg Ásbjörnsdóttir, Tanvir Johanning Bari, Satish Hulkund, Yvonne Winhofer, Carol Wysham","doi":"10.1089/dia.2025.0050","DOIUrl":null,"url":null,"abstract":"<p><p><b><i>Background:</i></b> ONWARDS 9 explored, for the first time, the effect of continuous glucose monitoring (CGM)-based titration of once-weekly insulin icodec (icodec) on glycemic control and safety outcomes in individuals with type 2 diabetes (T2D). <b><i>Methods:</i></b> In this 26-week, multicenter, single-arm, treat-to-target, phase 3b trial, insulin-naive adults with T2D (glycated hemoglobin [HbA1c] 7.0%-11.0%) initiated icodec at a starting dose of 70 U/week. Participants were provided with an intermittently scanned CGM device, and icodec doses were titrated weekly based on pre-breakfast CGM values (target: 80-130 mg/dL). The primary endpoint was change in HbA1c from week 0 to week 26. Exploratory endpoints included the percentage of time in range (TIR; 70-180 mg/dL), time above range (TAR; >180 mg/dL), and time below range (TBR; <54 mg/dL) from week 22 to week 26. Safety outcomes, including the number of hypoglycemia episodes, were assessed. <b><i>Results:</i></b> Of 58 participants screened, 51 received icodec treatment. HbA1c decreased from an observed mean of 8.18% at week 0 to an estimated mean of 7.00% at week 26. There was a statistically significant reduction in HbA1c of -1.17%-points (95% confidence interval: -1.36; -0.99, <i>P</i> < 0.0001). From week -2 to 0 to week 22-26, a concomitant clinically meaningful increase in TIR (54.4% to 76.4%) and decrease in TAR (45.2% to 22.9%) was observed; TBR remained low throughout the trial (week -2 to 0: 0.03%; week 22-26: 0.04%). No severe hypoglycemic episodes were reported during the trial, and no new safety concerns for icodec were identified. <b><i>Conclusion:</i></b> After 26 weeks of treatment with icodec titrated based on CGM data, there was a statistically significant reduction in HbA1c from baseline, and the internationally recommended CGM targets for TIR, TAR >180 mg/dL, and TBR <54 mg/dL were achieved. These findings suggest that CGM-based titration of icodec is a feasible method for initiating insulin therapy in T2D. <b><i>Trial registration:</i></b> ClinicalTrials.gov identifiers: NCT05823948.</p>","PeriodicalId":11159,"journal":{"name":"Diabetes technology & therapeutics","volume":" ","pages":""},"PeriodicalIF":5.7000,"publicationDate":"2025-03-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diabetes technology & therapeutics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1089/dia.2025.0050","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0
Abstract
Background: ONWARDS 9 explored, for the first time, the effect of continuous glucose monitoring (CGM)-based titration of once-weekly insulin icodec (icodec) on glycemic control and safety outcomes in individuals with type 2 diabetes (T2D). Methods: In this 26-week, multicenter, single-arm, treat-to-target, phase 3b trial, insulin-naive adults with T2D (glycated hemoglobin [HbA1c] 7.0%-11.0%) initiated icodec at a starting dose of 70 U/week. Participants were provided with an intermittently scanned CGM device, and icodec doses were titrated weekly based on pre-breakfast CGM values (target: 80-130 mg/dL). The primary endpoint was change in HbA1c from week 0 to week 26. Exploratory endpoints included the percentage of time in range (TIR; 70-180 mg/dL), time above range (TAR; >180 mg/dL), and time below range (TBR; <54 mg/dL) from week 22 to week 26. Safety outcomes, including the number of hypoglycemia episodes, were assessed. Results: Of 58 participants screened, 51 received icodec treatment. HbA1c decreased from an observed mean of 8.18% at week 0 to an estimated mean of 7.00% at week 26. There was a statistically significant reduction in HbA1c of -1.17%-points (95% confidence interval: -1.36; -0.99, P < 0.0001). From week -2 to 0 to week 22-26, a concomitant clinically meaningful increase in TIR (54.4% to 76.4%) and decrease in TAR (45.2% to 22.9%) was observed; TBR remained low throughout the trial (week -2 to 0: 0.03%; week 22-26: 0.04%). No severe hypoglycemic episodes were reported during the trial, and no new safety concerns for icodec were identified. Conclusion: After 26 weeks of treatment with icodec titrated based on CGM data, there was a statistically significant reduction in HbA1c from baseline, and the internationally recommended CGM targets for TIR, TAR >180 mg/dL, and TBR <54 mg/dL were achieved. These findings suggest that CGM-based titration of icodec is a feasible method for initiating insulin therapy in T2D. Trial registration: ClinicalTrials.gov identifiers: NCT05823948.
期刊介绍:
Diabetes Technology & Therapeutics is the only peer-reviewed journal providing healthcare professionals with information on new devices, drugs, drug delivery systems, and software for managing patients with diabetes. This leading international journal delivers practical information and comprehensive coverage of cutting-edge technologies and therapeutics in the field, and each issue highlights new pharmacological and device developments to optimize patient care.