Frequency regulation of two-area thermal and photovoltaic power system via flood algorithm

Q3 Mathematics
Serdar Ekinci , Davut Izci , Cebrail Turkeri , Aseel Smerat , Absalom E. Ezugwu , Laith Abualigah
{"title":"Frequency regulation of two-area thermal and photovoltaic power system via flood algorithm","authors":"Serdar Ekinci ,&nbsp;Davut Izci ,&nbsp;Cebrail Turkeri ,&nbsp;Aseel Smerat ,&nbsp;Absalom E. Ezugwu ,&nbsp;Laith Abualigah","doi":"10.1016/j.rico.2025.100539","DOIUrl":null,"url":null,"abstract":"<div><div>Frequency regulation is critical for maintaining balance between supply and demand in interconnected power systems, ensuring grid stability and preventing disruptions. This becomes increasingly important with the integration of renewable energy sources, such as photovoltaic (PV) units, which introduce variability and complexity into power systems. In this regards, this study presents a novel approach to frequency regulation in a two-area interconnected power system comprising thermal and PV units. A Proportional-Integral (PI) controller is designed, and its parameters are optimally tuned using the flood algorithm (FLA). The innovative use of the FLA ensures robust performance and efficient frequency stabilization under varying operational conditions. The implementation details of the FLA-tuned PI controller are provided, and its performance is rigorously compared with PI controllers tuned using several state-of-the-art optimization techniques. These include sea horse optimization, salp swarm algorithm, whale optimization algorithm, shuffled frog-leaping algorithm, and firefly algorithm. The comparative analysis is based on numerical results of performance metrics, demonstrating the robustness and effectiveness of each tuning method. Performance indices, including maximum overshoot, settling time and steady-state error are used to evaluate the robustness of the designed PI controllers. The frequency variations for the two-area thermal and PV power system are analyzed post-optimization, highlighting the superiority of the FLA-based PI controller in maintaining system stability under various operational conditions. The proposed FLA-based PI controller achieved a reduction in maximum overshoot by 28.3 %, a decrease in settling time by 23.4 %, and an improvement in steady-state error by 15.7 % compared to the next best-performing optimization method. These results demonstrate the significant advantages of the FLA in optimizing frequency regulation.</div></div>","PeriodicalId":34733,"journal":{"name":"Results in Control and Optimization","volume":"18 ","pages":"Article 100539"},"PeriodicalIF":0.0000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Results in Control and Optimization","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666720725000256","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Mathematics","Score":null,"Total":0}
引用次数: 0

Abstract

Frequency regulation is critical for maintaining balance between supply and demand in interconnected power systems, ensuring grid stability and preventing disruptions. This becomes increasingly important with the integration of renewable energy sources, such as photovoltaic (PV) units, which introduce variability and complexity into power systems. In this regards, this study presents a novel approach to frequency regulation in a two-area interconnected power system comprising thermal and PV units. A Proportional-Integral (PI) controller is designed, and its parameters are optimally tuned using the flood algorithm (FLA). The innovative use of the FLA ensures robust performance and efficient frequency stabilization under varying operational conditions. The implementation details of the FLA-tuned PI controller are provided, and its performance is rigorously compared with PI controllers tuned using several state-of-the-art optimization techniques. These include sea horse optimization, salp swarm algorithm, whale optimization algorithm, shuffled frog-leaping algorithm, and firefly algorithm. The comparative analysis is based on numerical results of performance metrics, demonstrating the robustness and effectiveness of each tuning method. Performance indices, including maximum overshoot, settling time and steady-state error are used to evaluate the robustness of the designed PI controllers. The frequency variations for the two-area thermal and PV power system are analyzed post-optimization, highlighting the superiority of the FLA-based PI controller in maintaining system stability under various operational conditions. The proposed FLA-based PI controller achieved a reduction in maximum overshoot by 28.3 %, a decrease in settling time by 23.4 %, and an improvement in steady-state error by 15.7 % compared to the next best-performing optimization method. These results demonstrate the significant advantages of the FLA in optimizing frequency regulation.
求助全文
约1分钟内获得全文 求助全文
来源期刊
Results in Control and Optimization
Results in Control and Optimization Mathematics-Control and Optimization
CiteScore
3.00
自引率
0.00%
发文量
51
审稿时长
91 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信