Accuracy and precision of segmentation and quantification of wrist bone microarchitecture using photon-counting computed tomography ex vivo

IF 3.5 2区 医学 Q2 ENDOCRINOLOGY & METABOLISM
Bone Pub Date : 2025-03-01 DOI:10.1016/j.bone.2025.117443
Jilmen Quintiens , Sarah L. Manske , Steven K. Boyd , Walter Coudyzer , Melissa Bevers , Evie Vereecke , Joop van den Bergh , G. Harry van Lenthe
{"title":"Accuracy and precision of segmentation and quantification of wrist bone microarchitecture using photon-counting computed tomography ex vivo","authors":"Jilmen Quintiens ,&nbsp;Sarah L. Manske ,&nbsp;Steven K. Boyd ,&nbsp;Walter Coudyzer ,&nbsp;Melissa Bevers ,&nbsp;Evie Vereecke ,&nbsp;Joop van den Bergh ,&nbsp;G. Harry van Lenthe","doi":"10.1016/j.bone.2025.117443","DOIUrl":null,"url":null,"abstract":"<div><div>The quantification of bone microarchitecture provides insight into bone health and the effects of disease or treatment, and is therefore highly relevant clinical information. Nonetheless, in vivo quantification of bone microarchitecture is mostly limited to high-resolution peripheral quantitative CT (HR-pQCT). This is a small field of view CT modality of which the gantry size only allows scanning of distal radius and tibia. Photon-counting CT (PCCT) is a novel clinical full-body CT with improved image resolution and quality compared to other clinical CT modalities, yet data on its capabilities in quantifying bone microarchitecture are limited. The aim of this study was to quantify the accuracy of two methods for trabecular bone segmentation on PCCT images as compared to the segmentations on micro-CT (μCT) and to use these segmentations to quantify the accuracy and agreement of trabecular bone morphometry measurements as compared to μCT, as well as the short-term precision.</div><div>This study analysed multimodal CT data, obtained from eight cadaveric forearms; the data includes two repeated PCCT scans, as well as a single HR-pQCT scan from the forearm, and μCT scans of all individual carpal bones. For each carpal bone, trabecular volumes of interest (VOI) were delineated on the μCT images, and the μCT reference segmentations and VOIs were resampled onto the PCCT and HR-pQCT images. HR-pQCT images were segmented with a global threshold of 320 mgHA/cm<sup>3</sup>; PCCT images were segmented with either an identical global threshold or with an adaptive thresholding algorithm. Trabecular bone-volume fraction (Tb.BV/TV), trabecular thickness (Tb.Th), trabecular number (Tb.N) and trabecular separation (Tb.Sp) were quantified for all segmented VOIs. Accuracy and agreement were calculated relative to μCT as the gold standard, short-term precision was calculated from the repeated PCCT scan.</div><div>For PCCT, adaptive threshold segmentation had significantly increased sensitivity compared to global threshold segmentation, along with a lower variance in its sensitivity and specificity. Concerning the microarchitecture quantification, for global threshold segmentation of PCCT images, correlations with μCT were significant, except for Tb.Sp. Correlation coefficients of Tb.BV/TV and Tb.N were not significantly different from those between HR-pQCT and μCT. Adaptive threshold segmentation led to higher correlation coefficients between PCCT and μCT of Tb.Th, Tb.N and Tb.Sp, although correlations of Tb.N remained poor for both PCCT and HR-pQCT. Moreover, adaptive thresholding led to a constant bias of Tb.BV/TV, Tb.Th and Tb.Sp, unlike the bias of HR-pQCT which was proportionally increasing with the size of the measurement. Finally, adaptive threshold segmentation led to a higher short-term precision than global threshold segmentation, with a root-mean-squared coefficient of variation below 0.65 % for all parameters.</div><div>We conclude that adaptive threshold segmentation is well-suited for the segmentation of PCCT images. Despite measurement error, our results indicate that these segmentations can be used for bone microarchitecture analyses of carpal bones with agreement and short-term precision comparable to HR-pQCT.</div></div>","PeriodicalId":9301,"journal":{"name":"Bone","volume":"194 ","pages":"Article 117443"},"PeriodicalIF":3.5000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bone","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S8756328225000559","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0

Abstract

The quantification of bone microarchitecture provides insight into bone health and the effects of disease or treatment, and is therefore highly relevant clinical information. Nonetheless, in vivo quantification of bone microarchitecture is mostly limited to high-resolution peripheral quantitative CT (HR-pQCT). This is a small field of view CT modality of which the gantry size only allows scanning of distal radius and tibia. Photon-counting CT (PCCT) is a novel clinical full-body CT with improved image resolution and quality compared to other clinical CT modalities, yet data on its capabilities in quantifying bone microarchitecture are limited. The aim of this study was to quantify the accuracy of two methods for trabecular bone segmentation on PCCT images as compared to the segmentations on micro-CT (μCT) and to use these segmentations to quantify the accuracy and agreement of trabecular bone morphometry measurements as compared to μCT, as well as the short-term precision.
This study analysed multimodal CT data, obtained from eight cadaveric forearms; the data includes two repeated PCCT scans, as well as a single HR-pQCT scan from the forearm, and μCT scans of all individual carpal bones. For each carpal bone, trabecular volumes of interest (VOI) were delineated on the μCT images, and the μCT reference segmentations and VOIs were resampled onto the PCCT and HR-pQCT images. HR-pQCT images were segmented with a global threshold of 320 mgHA/cm3; PCCT images were segmented with either an identical global threshold or with an adaptive thresholding algorithm. Trabecular bone-volume fraction (Tb.BV/TV), trabecular thickness (Tb.Th), trabecular number (Tb.N) and trabecular separation (Tb.Sp) were quantified for all segmented VOIs. Accuracy and agreement were calculated relative to μCT as the gold standard, short-term precision was calculated from the repeated PCCT scan.
For PCCT, adaptive threshold segmentation had significantly increased sensitivity compared to global threshold segmentation, along with a lower variance in its sensitivity and specificity. Concerning the microarchitecture quantification, for global threshold segmentation of PCCT images, correlations with μCT were significant, except for Tb.Sp. Correlation coefficients of Tb.BV/TV and Tb.N were not significantly different from those between HR-pQCT and μCT. Adaptive threshold segmentation led to higher correlation coefficients between PCCT and μCT of Tb.Th, Tb.N and Tb.Sp, although correlations of Tb.N remained poor for both PCCT and HR-pQCT. Moreover, adaptive thresholding led to a constant bias of Tb.BV/TV, Tb.Th and Tb.Sp, unlike the bias of HR-pQCT which was proportionally increasing with the size of the measurement. Finally, adaptive threshold segmentation led to a higher short-term precision than global threshold segmentation, with a root-mean-squared coefficient of variation below 0.65 % for all parameters.
We conclude that adaptive threshold segmentation is well-suited for the segmentation of PCCT images. Despite measurement error, our results indicate that these segmentations can be used for bone microarchitecture analyses of carpal bones with agreement and short-term precision comparable to HR-pQCT.
求助全文
约1分钟内获得全文 求助全文
来源期刊
Bone
Bone 医学-内分泌学与代谢
CiteScore
8.90
自引率
4.90%
发文量
264
审稿时长
30 days
期刊介绍: BONE is an interdisciplinary forum for the rapid publication of original articles and reviews on basic, translational, and clinical aspects of bone and mineral metabolism. The Journal also encourages submissions related to interactions of bone with other organ systems, including cartilage, endocrine, muscle, fat, neural, vascular, gastrointestinal, hematopoietic, and immune systems. Particular attention is placed on the application of experimental studies to clinical practice.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信