Virtual Colonoscopy: Retrospective Comparison of the Findings in Supine and Prone Positions.

IF 1.2 4区 医学 Q3 SURGERY
Mehmet Gürdal Demirci, Yasir Musa Kesgin
{"title":"Virtual Colonoscopy: Retrospective Comparison of the Findings in Supine and Prone Positions.","authors":"Mehmet Gürdal Demirci, Yasir Musa Kesgin","doi":"10.1177/15533506251325349","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Early detection of colorectal cancer (CRC) is significantly associated with reduced morbidity and mortality. Virtual colonoscopy (VC) is a minimally invasive, safe and well-tolerated alternative procedure to traditional colonoscopy. Therefore, we aimed to evaluate the findings of VC particularly in supine and prone positions as well as to contribute to the practical challenges of procedure.</p><p><strong>Methods: </strong>Total number of 20 patients who underwent VC were included in this retrospective study. After proper bowel cleansing was achieved, intestinal dilatation was performed by injecting air into the rectum. Two different shots were performed in the supine and prone positions. Additionally, intestinal diameters were measured from the cecum to the rectum at their widest point via 2-dimensional coronal reformat.</p><p><strong>Results: </strong>Polyps were detected in 3 patients which were confirmed by optical colonoscopy. The mean cecum diameter was detected as the largest diameter in the supine and prone examinations. In both supine and prone examinations, the distal descending colon was the most challenging site. Additionally, the mean descending colon diameter calculated in the prone position (40.9 ± 6.4 mm) was found to be statistically larger than descending colon diameter calculated in the supine position (36.1 ± 5.3 mm) (<i>P</i> = 0.001).</p><p><strong>Conclusions: </strong>Our findings clearly demonstrated that combination of prone and supine scanning provides clear field of vision on narrow parts of the colon which improves accurate estimation for polyp detection. Furthermore, VC appears to be more comfortable, safe, fast, and cost-efffective procedure for CRC screening with advantages of low radiation exposure, extracolonic findings and lack of sedation requirements.</p>","PeriodicalId":22095,"journal":{"name":"Surgical Innovation","volume":" ","pages":"15533506251325349"},"PeriodicalIF":1.2000,"publicationDate":"2025-03-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Surgical Innovation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15533506251325349","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Early detection of colorectal cancer (CRC) is significantly associated with reduced morbidity and mortality. Virtual colonoscopy (VC) is a minimally invasive, safe and well-tolerated alternative procedure to traditional colonoscopy. Therefore, we aimed to evaluate the findings of VC particularly in supine and prone positions as well as to contribute to the practical challenges of procedure.

Methods: Total number of 20 patients who underwent VC were included in this retrospective study. After proper bowel cleansing was achieved, intestinal dilatation was performed by injecting air into the rectum. Two different shots were performed in the supine and prone positions. Additionally, intestinal diameters were measured from the cecum to the rectum at their widest point via 2-dimensional coronal reformat.

Results: Polyps were detected in 3 patients which were confirmed by optical colonoscopy. The mean cecum diameter was detected as the largest diameter in the supine and prone examinations. In both supine and prone examinations, the distal descending colon was the most challenging site. Additionally, the mean descending colon diameter calculated in the prone position (40.9 ± 6.4 mm) was found to be statistically larger than descending colon diameter calculated in the supine position (36.1 ± 5.3 mm) (P = 0.001).

Conclusions: Our findings clearly demonstrated that combination of prone and supine scanning provides clear field of vision on narrow parts of the colon which improves accurate estimation for polyp detection. Furthermore, VC appears to be more comfortable, safe, fast, and cost-efffective procedure for CRC screening with advantages of low radiation exposure, extracolonic findings and lack of sedation requirements.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Surgical Innovation
Surgical Innovation 医学-外科
CiteScore
2.90
自引率
0.00%
发文量
72
审稿时长
6-12 weeks
期刊介绍: Surgical Innovation (SRI) is a peer-reviewed bi-monthly journal focusing on minimally invasive surgical techniques, new instruments such as laparoscopes and endoscopes, and new technologies. SRI prepares surgeons to think and work in "the operating room of the future" through learning new techniques, understanding and adapting to new technologies, maintaining surgical competencies, and applying surgical outcomes data to their practices. This journal is a member of the Committee on Publication Ethics (COPE).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信