A Human-Prosthesis Coupled Musculoskeletal Model for Transtibial Amputees.

IF 4.4 2区 医学 Q2 ENGINEERING, BIOMEDICAL
Yuwen Lu, Yan Huang, Rui Yang, Yong Wang, Yosuke Ikegami, Yoshihiko Nakamura, Qining Wang
{"title":"A Human-Prosthesis Coupled Musculoskeletal Model for Transtibial Amputees.","authors":"Yuwen Lu, Yan Huang, Rui Yang, Yong Wang, Yosuke Ikegami, Yoshihiko Nakamura, Qining Wang","doi":"10.1109/TBME.2025.3531408","DOIUrl":null,"url":null,"abstract":"<p><p>In this paper, we present a human-prosthesis coupled full-body musculoskeletal model that integrates the dynamics of the muscle-driven human body and a motor-driven robotic prosthesis. This model can be used to perform the inverse kinematics and dynamics calculation based on measurements for amputees wearing a force-controlled or position-controlled prosthesis. As a result, we can analyze the impacts of prostheses on amputee kinetic states, such as joint torques and muscle forces. To verify the proposed model, we conducted experiments involving four transtibial amputees wearing passive prostheses and our self-developed robotic prostheses. We estimated the joint angles, joint torques, and muscle forces on the intact side and on the residual side of the subjects. The indexes reflecting the symmetry and magnitude of muscle forces were introduced to evaluate the effects of different prostheses on transtibial amputees. The indexes of muscle force magnitude indicate that the posterior thigh muscles of the residual limb exhibit significant compensation during walking. And the indexes of muscle force symmetry indicate that active prostheses with higher damping rates work better for fast walking speeds, while those with lower damping rates are more suitable for slow walking speeds. The proposed approach may offer a novel method for evaluating prostheses that considers muscle-level kinetics, thus enhancing understanding of the impact of different prostheses on the movements of amputees.</p>","PeriodicalId":13245,"journal":{"name":"IEEE Transactions on Biomedical Engineering","volume":"PP ","pages":""},"PeriodicalIF":4.4000,"publicationDate":"2025-01-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1109/TBME.2025.3531408","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

In this paper, we present a human-prosthesis coupled full-body musculoskeletal model that integrates the dynamics of the muscle-driven human body and a motor-driven robotic prosthesis. This model can be used to perform the inverse kinematics and dynamics calculation based on measurements for amputees wearing a force-controlled or position-controlled prosthesis. As a result, we can analyze the impacts of prostheses on amputee kinetic states, such as joint torques and muscle forces. To verify the proposed model, we conducted experiments involving four transtibial amputees wearing passive prostheses and our self-developed robotic prostheses. We estimated the joint angles, joint torques, and muscle forces on the intact side and on the residual side of the subjects. The indexes reflecting the symmetry and magnitude of muscle forces were introduced to evaluate the effects of different prostheses on transtibial amputees. The indexes of muscle force magnitude indicate that the posterior thigh muscles of the residual limb exhibit significant compensation during walking. And the indexes of muscle force symmetry indicate that active prostheses with higher damping rates work better for fast walking speeds, while those with lower damping rates are more suitable for slow walking speeds. The proposed approach may offer a novel method for evaluating prostheses that considers muscle-level kinetics, thus enhancing understanding of the impact of different prostheses on the movements of amputees.

经胫骨截肢者的人体-假肢耦合肌肉骨骼模型。
在本文中,我们提出了一个人体-假肢耦合全身肌肉骨骼模型,该模型集成了肌肉驱动的人体动力学和电机驱动的机器人假肢动力学。该模型可用于根据佩戴力控或位控假肢的截肢者的测量结果,进行反运动学和动力学计算。因此,我们可以分析假肢对截肢者运动状态的影响,如关节扭矩和肌肉力量。为了验证所提出的模型,我们对四名佩戴被动式假肢和自主研发的机器人假肢的经胫截肢者进行了实验。我们估算了受试者完整侧和残余侧的关节角度、关节扭矩和肌肉力量。我们引入了反映对称性和肌力大小的指标,以评估不同假肢对经趾截肢者的影响。肌力大小指数表明,残肢大腿后侧肌肉在行走过程中表现出明显的代偿。肌力对称性指数表明,阻尼率越高的主动假肢越适合快步行走,而阻尼率越低的主动假肢越适合慢步行走。所提出的方法可为评估假肢提供一种考虑肌肉水平动力学的新方法,从而加深人们对不同假肢对截肢者运动影响的理解。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
IEEE Transactions on Biomedical Engineering
IEEE Transactions on Biomedical Engineering 工程技术-工程:生物医学
CiteScore
9.40
自引率
4.30%
发文量
880
审稿时长
2.5 months
期刊介绍: IEEE Transactions on Biomedical Engineering contains basic and applied papers dealing with biomedical engineering. Papers range from engineering development in methods and techniques with biomedical applications to experimental and clinical investigations with engineering contributions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信