Adaptive Feedforward Model Predictive Control for Torque Generation Through Asynchronous Intrafascicular Multi-Electrode Stimulation.

IF 4.4 2区 医学 Q2 ENGINEERING, BIOMEDICAL
Leonardo M Cavalcanti, W Mitchel Thomas, David J Warren, V John Mathews
{"title":"Adaptive Feedforward Model Predictive Control for Torque Generation Through Asynchronous Intrafascicular Multi-Electrode Stimulation.","authors":"Leonardo M Cavalcanti, W Mitchel Thomas, David J Warren, V John Mathews","doi":"10.1109/TBME.2025.3530924","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Fatigue-resistant and graded muscle forces can be evoked through asynchronous intrafascicular multi-electrode stimulation (aIFMS). Prior studies on controlled force generation using aIFMS employed either a feedback controller featuring a multiple-input single-output delayed-integral (MISO-I) control law, or a feedforward controller with a non-predictive model-based policy. However, these controllers resulted in lagged responses as stimulation was coordinated via intentional time delays and lacked immediate control corrections. To address these limitations, this paper presents an adaptive feedforward model predictive controller (aF-MPC) for isometric torque control.</p><p><strong>Methods: </strong>The aF-MPC was evaluated in experiments in anesthetized felines implanted with Utah Slanted Electrode Arrays in their sciatic nerves. This controller redesigned the existing aIFMS feedforward controller by enhancing it with a predictive policy and an online model learning algorithm to compensate for unaccounted aIFMS effects. Statistical comparisons of the aF-MPC and the (non-adaptive) F-MPC trials and observational comparisons of the aF-MPC and the MISO-I controller were performed for different desired trajectories.</p><p><strong>Results: </strong>The aF-MPC exhibited significant performance improvements over the F-MPC across multiple metrics. Observationally, the aF-MPC showed improvements in all performance metrics over the MISO-I controller.</p><p><strong>Conclusion: </strong>Despite unknown dynamics in the aIFMS system, this paper's aF-MPC outperformed alternate approaches as it accurately tracked desired torque profiles even under high-frequency commands.</p><p><strong>Significance: </strong>The application of the aF-MPC in conjunction with aIFMS could provide a better avenue for developing naturalistic motor neuroprosthesis than F-MPCs or MISO-I controllers.</p>","PeriodicalId":13245,"journal":{"name":"IEEE Transactions on Biomedical Engineering","volume":"PP ","pages":""},"PeriodicalIF":4.4000,"publicationDate":"2025-01-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1109/TBME.2025.3530924","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: Fatigue-resistant and graded muscle forces can be evoked through asynchronous intrafascicular multi-electrode stimulation (aIFMS). Prior studies on controlled force generation using aIFMS employed either a feedback controller featuring a multiple-input single-output delayed-integral (MISO-I) control law, or a feedforward controller with a non-predictive model-based policy. However, these controllers resulted in lagged responses as stimulation was coordinated via intentional time delays and lacked immediate control corrections. To address these limitations, this paper presents an adaptive feedforward model predictive controller (aF-MPC) for isometric torque control.

Methods: The aF-MPC was evaluated in experiments in anesthetized felines implanted with Utah Slanted Electrode Arrays in their sciatic nerves. This controller redesigned the existing aIFMS feedforward controller by enhancing it with a predictive policy and an online model learning algorithm to compensate for unaccounted aIFMS effects. Statistical comparisons of the aF-MPC and the (non-adaptive) F-MPC trials and observational comparisons of the aF-MPC and the MISO-I controller were performed for different desired trajectories.

Results: The aF-MPC exhibited significant performance improvements over the F-MPC across multiple metrics. Observationally, the aF-MPC showed improvements in all performance metrics over the MISO-I controller.

Conclusion: Despite unknown dynamics in the aIFMS system, this paper's aF-MPC outperformed alternate approaches as it accurately tracked desired torque profiles even under high-frequency commands.

Significance: The application of the aF-MPC in conjunction with aIFMS could provide a better avenue for developing naturalistic motor neuroprosthesis than F-MPCs or MISO-I controllers.

求助全文
约1分钟内获得全文 求助全文
来源期刊
IEEE Transactions on Biomedical Engineering
IEEE Transactions on Biomedical Engineering 工程技术-工程:生物医学
CiteScore
9.40
自引率
4.30%
发文量
880
审稿时长
2.5 months
期刊介绍: IEEE Transactions on Biomedical Engineering contains basic and applied papers dealing with biomedical engineering. Papers range from engineering development in methods and techniques with biomedical applications to experimental and clinical investigations with engineering contributions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信