Clinical outcomes of patients undergoing hemodialysis with cool versus standard dialysate: A systematic review and meta-analysis.

IF 4.3 3区 医学 Q1 UROLOGY & NEPHROLOGY
Subhash Chander, Rabia Latif, Ahmad Bin Aamir, Fnu Sorath, Abhi Chand Lohana, Mohammed Yaqub Nadeem, Om Parkash
{"title":"Clinical outcomes of patients undergoing hemodialysis with cool versus standard dialysate: A systematic review and meta-analysis.","authors":"Subhash Chander, Rabia Latif, Ahmad Bin Aamir, Fnu Sorath, Abhi Chand Lohana, Mohammed Yaqub Nadeem, Om Parkash","doi":"10.1159/000544924","DOIUrl":null,"url":null,"abstract":"<p><p>Rationale &amp; Objective: Clinical practice guidelines recommend lower (35.0°C-35.5°C) instead of standard dialysate temperature (36.5°C-37.0°C) to mitigate the risk of intradialytic hypotension. However, many studies have been available since the recommendations were published. Hence, the current study aims to provide an updated meta-analysis of clinical outcomes with cold versus standard dialysate.</p><p><strong>Study design: </strong>Systematic review and meta-analysis of eligible articles indexed in PubMed, Cochrane, Web of Science, and Scopus.</p><p><strong>Participants: </strong>Hemodialysis patients Exposure: Cooled versus standard dialysate.</p><p><strong>Outcome: </strong>Intradialytic hypotension, mean arterial pressure, thermal-related discomfort, and body temperature.</p><p><strong>Analytical approach: </strong>The random effects model was used for all outcomes due to high heterogeneity (I2: interdialytic hypotension=60%, mean arterial pressure=72%, symptoms of discomfort =41%, and decrease in body temperature=87%). The \"leave-one-out\" approach was used for sensitivity analysis, and the Cochrane risk-of-bias tool was used to evaluate study quality.</p><p><strong>Results: </strong>Pooled data from 31 studies indicate that cooled dialysis may be associated with a lower risk of intradialytic hypotension [RR 0.67 (95%CI 0.48-0.93), p=0.02] and higher mean arterial pressure [MD 7.18 (95%CI 3.79-10.58), p<0.01] compared to standard temperature dialysis. However, cooled dialysis was associated with a higher risk of discomfort [RR 1.55 (95% CI 1.25-1.93], p<0.01] and a decrease in body temperature [MD -0.29 (95%CI -0.52--0.05), p=0.02]. Only five studies had a low risk of bias.</p><p><strong>Limitations: </strong>Most included studies were from over a decade ago, had a small participant size, and did not report other critical long-term outcomes such as mortality, cardiovascular events, treatment discontinuation, or hospitalization rate.</p><p><strong>Registration: </strong>Registered with ID CRD42024589307 at PROSPERO Conclusions: Using cooled dialysate might be a simple approach to reduce interdialytic hypotension risk and increase mean arterial pressure, albeit at the cost of patient discomfort. The limitations associated with the quality of included studies underscore the need for high-quality, multicenter studies with large/diverse study populations.</p>","PeriodicalId":7570,"journal":{"name":"American Journal of Nephrology","volume":" ","pages":"1-28"},"PeriodicalIF":4.3000,"publicationDate":"2025-03-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of Nephrology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000544924","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Rationale & Objective: Clinical practice guidelines recommend lower (35.0°C-35.5°C) instead of standard dialysate temperature (36.5°C-37.0°C) to mitigate the risk of intradialytic hypotension. However, many studies have been available since the recommendations were published. Hence, the current study aims to provide an updated meta-analysis of clinical outcomes with cold versus standard dialysate.

Study design: Systematic review and meta-analysis of eligible articles indexed in PubMed, Cochrane, Web of Science, and Scopus.

Participants: Hemodialysis patients Exposure: Cooled versus standard dialysate.

Outcome: Intradialytic hypotension, mean arterial pressure, thermal-related discomfort, and body temperature.

Analytical approach: The random effects model was used for all outcomes due to high heterogeneity (I2: interdialytic hypotension=60%, mean arterial pressure=72%, symptoms of discomfort =41%, and decrease in body temperature=87%). The "leave-one-out" approach was used for sensitivity analysis, and the Cochrane risk-of-bias tool was used to evaluate study quality.

Results: Pooled data from 31 studies indicate that cooled dialysis may be associated with a lower risk of intradialytic hypotension [RR 0.67 (95%CI 0.48-0.93), p=0.02] and higher mean arterial pressure [MD 7.18 (95%CI 3.79-10.58), p<0.01] compared to standard temperature dialysis. However, cooled dialysis was associated with a higher risk of discomfort [RR 1.55 (95% CI 1.25-1.93], p<0.01] and a decrease in body temperature [MD -0.29 (95%CI -0.52--0.05), p=0.02]. Only five studies had a low risk of bias.

Limitations: Most included studies were from over a decade ago, had a small participant size, and did not report other critical long-term outcomes such as mortality, cardiovascular events, treatment discontinuation, or hospitalization rate.

Registration: Registered with ID CRD42024589307 at PROSPERO Conclusions: Using cooled dialysate might be a simple approach to reduce interdialytic hypotension risk and increase mean arterial pressure, albeit at the cost of patient discomfort. The limitations associated with the quality of included studies underscore the need for high-quality, multicenter studies with large/diverse study populations.

求助全文
约1分钟内获得全文 求助全文
来源期刊
American Journal of Nephrology
American Journal of Nephrology 医学-泌尿学与肾脏学
CiteScore
7.50
自引率
2.40%
发文量
74
审稿时长
4-8 weeks
期刊介绍: The ''American Journal of Nephrology'' is a peer-reviewed journal that focuses on timely topics in both basic science and clinical research. Papers are divided into several sections, including:
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信