The Biomechanical Importance of Bone Block Positioning in Glenoid Augmentation: Every Millimeter Matters.

IF 4.2 1区 医学 Q1 ORTHOPEDICS
Sebastian Oenning, Jens Wermers, Alina Köhler, Julia Sußiek, Mats Wiethölter, Michael J Raschke, J Christoph Katthagen
{"title":"The Biomechanical Importance of Bone Block Positioning in Glenoid Augmentation: Every Millimeter Matters.","authors":"Sebastian Oenning, Jens Wermers, Alina Köhler, Julia Sußiek, Mats Wiethölter, Michael J Raschke, J Christoph Katthagen","doi":"10.1177/03635465251322796","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>In the presence of anterior glenoid bone loss (aGBL), options for bony glenoid augmentation include Latarjet procedures and free bone block transfers. Bone graft placement is challenging, and malposition causes complications, such as recurrent instability or osteoarthritis.</p><p><strong>Hypothesis: </strong>With minimal changes in bone block positioning, osteochondral shoulder stability cannot be restored sufficiently.</p><p><strong>Study design: </strong>Controlled laboratory study.</p><p><strong>Methods: </strong>In a robotic test setup, 14 human cadaveric scapulae were included. Soft tissue was resected, and matching artificial humeri were selected for each specimen. Testing was performed in 60° of glenohumeral abduction with 50 N of glenohumeral compression and anterior-directed translational force to the humerus. Application of 20% aGBL and screw fixation of artificial bone blocks (artBBs) with different buildup shells allowed the following testing stages: (1) intact, (2) 20% aGBL, (3) flush artBB, (4) 1-mm medialized artBB, and (5) 1-mm lateralized artBB. The stability ratio (SR) and medial-lateral humeral head starting position were assessed.</p><p><strong>Results: </strong>Specimens with 20% aGBL provided lower mean SRs than native joints (20.6% [SD, 4.7%] vs 27.8% [SD, 6.7%]; <i>P</i> < .0001). Flush artBB placement (mean, 35.4%; SD, 7.7%) led to an increased SR compared with both native joints (<i>P</i> = .002) and 20% aGBL (<i>P</i> < .0001). The mean SR in 1-mm medialized artBBs (21.5%; SD, 5.7%) did not differ compared with that for 20% aGBL (<i>P</i> = .908). One-millimeter lateralized artBBs (mean, 40.8%; SD, 5%) provided higher SR and more lateral humeral head starting positions compared with flush artBB (<i>P</i> = .003 and <i>P</i> = .003, respectively).</p><p><strong>Conclusion: </strong>In the presence of aGBL, flush bone block placement restores osteochondral glenohumeral stability, while a 1-mm medialized bone block fails to increase stability. Bone block lateralization of 1 mm provides higher stability but is associated with humeral head lateralization.</p><p><strong>Clinical relevance: </strong>Glenoid bone block augmentations are established in patients with glenohumeral instability and aGBL. In the case of bone block malposition, complications like recurrent instability or the development of osteoarthritis can occur. This study underlines the importance of accurate bone block placement since only minimum bone block malposition relevantly affects osteochondral shoulder biomechanics.</p>","PeriodicalId":55528,"journal":{"name":"American Journal of Sports Medicine","volume":" ","pages":"3635465251322796"},"PeriodicalIF":4.2000,"publicationDate":"2025-03-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of Sports Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/03635465251322796","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: In the presence of anterior glenoid bone loss (aGBL), options for bony glenoid augmentation include Latarjet procedures and free bone block transfers. Bone graft placement is challenging, and malposition causes complications, such as recurrent instability or osteoarthritis.

Hypothesis: With minimal changes in bone block positioning, osteochondral shoulder stability cannot be restored sufficiently.

Study design: Controlled laboratory study.

Methods: In a robotic test setup, 14 human cadaveric scapulae were included. Soft tissue was resected, and matching artificial humeri were selected for each specimen. Testing was performed in 60° of glenohumeral abduction with 50 N of glenohumeral compression and anterior-directed translational force to the humerus. Application of 20% aGBL and screw fixation of artificial bone blocks (artBBs) with different buildup shells allowed the following testing stages: (1) intact, (2) 20% aGBL, (3) flush artBB, (4) 1-mm medialized artBB, and (5) 1-mm lateralized artBB. The stability ratio (SR) and medial-lateral humeral head starting position were assessed.

Results: Specimens with 20% aGBL provided lower mean SRs than native joints (20.6% [SD, 4.7%] vs 27.8% [SD, 6.7%]; P < .0001). Flush artBB placement (mean, 35.4%; SD, 7.7%) led to an increased SR compared with both native joints (P = .002) and 20% aGBL (P < .0001). The mean SR in 1-mm medialized artBBs (21.5%; SD, 5.7%) did not differ compared with that for 20% aGBL (P = .908). One-millimeter lateralized artBBs (mean, 40.8%; SD, 5%) provided higher SR and more lateral humeral head starting positions compared with flush artBB (P = .003 and P = .003, respectively).

Conclusion: In the presence of aGBL, flush bone block placement restores osteochondral glenohumeral stability, while a 1-mm medialized bone block fails to increase stability. Bone block lateralization of 1 mm provides higher stability but is associated with humeral head lateralization.

Clinical relevance: Glenoid bone block augmentations are established in patients with glenohumeral instability and aGBL. In the case of bone block malposition, complications like recurrent instability or the development of osteoarthritis can occur. This study underlines the importance of accurate bone block placement since only minimum bone block malposition relevantly affects osteochondral shoulder biomechanics.

骨块定位在盂成形术中的生物力学重要性:每毫米都很重要
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
9.30
自引率
12.50%
发文量
425
审稿时长
3 months
期刊介绍: An invaluable resource for the orthopaedic sports medicine community, _The American Journal of Sports Medicine_ is a peer-reviewed scientific journal, first published in 1972. It is the official publication of the [American Orthopaedic Society for Sports Medicine (AOSSM)](http://www.sportsmed.org/)! The journal acts as an important forum for independent orthopaedic sports medicine research and education, allowing clinical practitioners the ability to make decisions based on sound scientific information. This journal is a must-read for: * Orthopaedic Surgeons and Specialists * Sports Medicine Physicians * Physiatrists * Athletic Trainers * Team Physicians * And Physical Therapists
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信