Optimization of imaging conditions for technetium-99m dimercaptosuccinic acid single photon emission computed tomography examinations in neonates.

IF 1.3 4区 医学 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Nuclear Medicine Communications Pub Date : 2025-05-01 Epub Date: 2025-03-03 DOI:10.1097/MNM.0000000000001962
Haruto Kimoto, Yoshiki Owaki, Kazuya Minamishima, Kazumasa Inoue
{"title":"Optimization of imaging conditions for technetium-99m dimercaptosuccinic acid single photon emission computed tomography examinations in neonates.","authors":"Haruto Kimoto, Yoshiki Owaki, Kazuya Minamishima, Kazumasa Inoue","doi":"10.1097/MNM.0000000000001962","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>This study validated the optimal acquisition and reconstruction conditions for technetium-99m dimercaptosuccinic acid single-photon emission computed tomography examinations in neonates.</p><p><strong>Methods: </strong>We developed renal phantoms representing neonatal and adult kidneys, derived from clinical data to achieve this. The radioactivity concentration to be encapsulated in the renal part was adjusted according to the Japanese consensus guidelines for the appropriate implementation of pediatric nuclear medicine examinations. The evaluation of optimal acquisition conditions considered factors such as acquisition time and magnification ratio, while the determination of optimal reconstruction conditions focused on the cutoff frequency of the Butterworth filter and the appropriate correction methods. The physical evaluation assessed defect contrast and background coefficient of variation, while the visual evaluation assessed the ability of the images to depict the defect.</p><p><strong>Results: </strong>The defect contrast was almost constant after acquisition times of 10 min for neonates and 12 min for adults. For the magnification ratio, the effect was greater for neonates than for adults. In addition, in contrast to adults, the use of resolution recovery significantly decreased scores in visual evaluation in neonates.</p><p><strong>Conclusion: </strong>Our study suggests better images can be obtained in neonates with shorter acquisition times than adults. In addition, the optimal reconstruction conditions are shown to differ between neonates and adults.</p>","PeriodicalId":19708,"journal":{"name":"Nuclear Medicine Communications","volume":" ","pages":"427-436"},"PeriodicalIF":1.3000,"publicationDate":"2025-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Medicine Communications","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/MNM.0000000000001962","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/3/3 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: This study validated the optimal acquisition and reconstruction conditions for technetium-99m dimercaptosuccinic acid single-photon emission computed tomography examinations in neonates.

Methods: We developed renal phantoms representing neonatal and adult kidneys, derived from clinical data to achieve this. The radioactivity concentration to be encapsulated in the renal part was adjusted according to the Japanese consensus guidelines for the appropriate implementation of pediatric nuclear medicine examinations. The evaluation of optimal acquisition conditions considered factors such as acquisition time and magnification ratio, while the determination of optimal reconstruction conditions focused on the cutoff frequency of the Butterworth filter and the appropriate correction methods. The physical evaluation assessed defect contrast and background coefficient of variation, while the visual evaluation assessed the ability of the images to depict the defect.

Results: The defect contrast was almost constant after acquisition times of 10 min for neonates and 12 min for adults. For the magnification ratio, the effect was greater for neonates than for adults. In addition, in contrast to adults, the use of resolution recovery significantly decreased scores in visual evaluation in neonates.

Conclusion: Our study suggests better images can be obtained in neonates with shorter acquisition times than adults. In addition, the optimal reconstruction conditions are shown to differ between neonates and adults.

新生儿锝-99m 二巯基丁二酸单光子发射计算机断层扫描成像条件的优化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.20
自引率
6.70%
发文量
212
审稿时长
3-8 weeks
期刊介绍: Nuclear Medicine Communications, the official journal of the British Nuclear Medicine Society, is a rapid communications journal covering nuclear medicine and molecular imaging with radionuclides, and the basic supporting sciences. As well as clinical research and commentary, manuscripts describing research on preclinical and basic sciences (radiochemistry, radiopharmacy, radiobiology, radiopharmacology, medical physics, computing and engineering, and technical and nursing professions involved in delivering nuclear medicine services) are welcomed, as the journal is intended to be of interest internationally to all members of the many medical and non-medical disciplines involved in nuclear medicine. In addition to papers reporting original studies, frankly written editorials and topical reviews are a regular feature of the journal.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信