Bowel tracking for MR-guided radiotherapy: simultaneous optimization of small bowel imaging and tracking.

IF 3.3 3区 医学 Q2 ENGINEERING, BIOMEDICAL
Saskia Laura Corry Damen, Astrid L H M W van Lier, Cornel Zachiu, Bas W Raaymakers
{"title":"Bowel tracking for MR-guided radiotherapy: simultaneous optimization of small bowel imaging and tracking.","authors":"Saskia Laura Corry Damen, Astrid L H M W van Lier, Cornel Zachiu, Bas W Raaymakers","doi":"10.1088/1361-6560/adbbac","DOIUrl":null,"url":null,"abstract":"<p><p>Background and purpose&#xD;The small bowel is one of the most radiosensitive organs-at-risk during radiotherapy in the pelvis. This is further complicated due to anatomical and physiological motion. Thus, its accurate tracking becomes of particular importance during therapy delivery, to obtain better dose-toxicity relations and/or to perform safe adaptive treatments. The aim of this work is to simultaneously optimize the MR imaging sequence and motion estimation solution towards improved small bowel tracking precision during radiotherapy delivery. &#xD;&#xD;Materials and methods&#xD;An MRI sequence was optimized, to adhere to the respiratory and peristaltic motion frequencies, by assesing the performance of an image registration algorithm on data acquired on volunteers and patients. In terms of tracking, three registration algorithms, previously-employed in the scope of image-guided radiotherapy, were investigated. &#xD;The optimized scan was acquired for 7.5 min., in 18 patients and for 15 min., in 10 volunteers at a 1.5T MRL (Unity, Elekta AB). The tracking precision was evaluated and validated by means of three different quality assurance criteria: Structural Similarity Index Metric (SSIM), Inverse Consistency (IC) and Absolute Intensity Difference (AID). &#xD;&#xD;Results&#xD;The optimal sequence was a balanced Fast Field Echo (FFE), which acquired a 3D volume of the abdomen, with a dynamic scan time of 1.8 seconds. An optical flow algorithm performed best and which was able to resolve most of the motion. This was shown by mean IC values of < 1 mm and a mean SSIM >0.9 for the majority of the cases.&#xD;A strong positive correlation (p<0.001) between the registration performance and visceral fat percentage was found, where a higher visceral fat percentage gave a better registration due to the better image contrast. &#xD;&#xD;Conclusions&#xD;A method for simultaneous optimization of imaging and tracking was presented, which derived an imaging and registration procedure for accurate small bowel tracking on the MR-Linac.</p>","PeriodicalId":20185,"journal":{"name":"Physics in medicine and biology","volume":" ","pages":""},"PeriodicalIF":3.3000,"publicationDate":"2025-02-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physics in medicine and biology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1361-6560/adbbac","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background and purpose The small bowel is one of the most radiosensitive organs-at-risk during radiotherapy in the pelvis. This is further complicated due to anatomical and physiological motion. Thus, its accurate tracking becomes of particular importance during therapy delivery, to obtain better dose-toxicity relations and/or to perform safe adaptive treatments. The aim of this work is to simultaneously optimize the MR imaging sequence and motion estimation solution towards improved small bowel tracking precision during radiotherapy delivery. Materials and methods An MRI sequence was optimized, to adhere to the respiratory and peristaltic motion frequencies, by assesing the performance of an image registration algorithm on data acquired on volunteers and patients. In terms of tracking, three registration algorithms, previously-employed in the scope of image-guided radiotherapy, were investigated. The optimized scan was acquired for 7.5 min., in 18 patients and for 15 min., in 10 volunteers at a 1.5T MRL (Unity, Elekta AB). The tracking precision was evaluated and validated by means of three different quality assurance criteria: Structural Similarity Index Metric (SSIM), Inverse Consistency (IC) and Absolute Intensity Difference (AID). Results The optimal sequence was a balanced Fast Field Echo (FFE), which acquired a 3D volume of the abdomen, with a dynamic scan time of 1.8 seconds. An optical flow algorithm performed best and which was able to resolve most of the motion. This was shown by mean IC values of < 1 mm and a mean SSIM >0.9 for the majority of the cases. A strong positive correlation (p<0.001) between the registration performance and visceral fat percentage was found, where a higher visceral fat percentage gave a better registration due to the better image contrast. Conclusions A method for simultaneous optimization of imaging and tracking was presented, which derived an imaging and registration procedure for accurate small bowel tracking on the MR-Linac.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Physics in medicine and biology
Physics in medicine and biology 医学-工程:生物医学
CiteScore
6.50
自引率
14.30%
发文量
409
审稿时长
2 months
期刊介绍: The development and application of theoretical, computational and experimental physics to medicine, physiology and biology. Topics covered are: therapy physics (including ionizing and non-ionizing radiation); biomedical imaging (e.g. x-ray, magnetic resonance, ultrasound, optical and nuclear imaging); image-guided interventions; image reconstruction and analysis (including kinetic modelling); artificial intelligence in biomedical physics and analysis; nanoparticles in imaging and therapy; radiobiology; radiation protection and patient dose monitoring; radiation dosimetry
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信