Differences in Direct Fick and Thermodilution Measurements of Cardiac Output: Impact on Pulmonary Hypertension Classification.

IF 2.2 4区 医学 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS
Pulmonary Circulation Pub Date : 2025-02-26 eCollection Date: 2025-01-01 DOI:10.1002/pul2.70053
Garry W Hamilton, Luke R Fletcher, William Harley, Robert Azzopardi, R Kimberly Chan, Jordan Fulcher, Lachlan F Miles, Omar Farouque, Mark C G Horrigan
{"title":"Differences in Direct Fick and Thermodilution Measurements of Cardiac Output: Impact on Pulmonary Hypertension Classification.","authors":"Garry W Hamilton, Luke R Fletcher, William Harley, Robert Azzopardi, R Kimberly Chan, Jordan Fulcher, Lachlan F Miles, Omar Farouque, Mark C G Horrigan","doi":"10.1002/pul2.70053","DOIUrl":null,"url":null,"abstract":"<p><p>Direct Fick (DF) and bolus thermodilution (TD) are endorsed by pulmonary hypertension (PH) guidelines to measure cardiac output. In contemporary practice, agreement between methods is unknown, as are the diagnostic consequences of disagreement. We sought to evaluate the frequency and degree of disagreements between cardiac output measurement techniques and assess their impact on the hemodynamic assessment of PH. This was a single-center study that included 182 patients who had cardiac output concurrently measured by DF and TD. Oxygen consumption was measured by indirect calorimetry. Agreement between DF and bolus TD cardiac output was assessed using Bland-Altman analysis. The median DF and TD cardiac outputs were 5.42 L/min (interquartile range [IQR] 3.90-7.41) and 4.10 L/min (IQR 3.47-5.10), respectively. Significant disagreement was observed with DF yielding higher cardiac output results than TD. Mean error was proportional to cardiac output (-3.75% at 3 L/min to +44.5% at 7 L/min), and limits of agreement were wide. Disagreement was increased by 19.2% in the presence of least moderate tricuspid regurgitation and by 16.0% in patients with atrial fibrillation. Among 152 patients with PH, hemodynamic classification discordance occurred in 18 (11.8%) patients. Disagreement between DF and TD was observed, which resulted in a discrepant hemodynamic classification in approximately 12% of patients. These techniques should, therefore, not be used interchangeably for serial surveillance, and without a clinical gold standard, a rationale exists for utilizing both methods concurrently in certain clinical situations.</p>","PeriodicalId":20927,"journal":{"name":"Pulmonary Circulation","volume":"15 1","pages":"e70053"},"PeriodicalIF":2.2000,"publicationDate":"2025-02-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11865337/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pulmonary Circulation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/pul2.70053","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Direct Fick (DF) and bolus thermodilution (TD) are endorsed by pulmonary hypertension (PH) guidelines to measure cardiac output. In contemporary practice, agreement between methods is unknown, as are the diagnostic consequences of disagreement. We sought to evaluate the frequency and degree of disagreements between cardiac output measurement techniques and assess their impact on the hemodynamic assessment of PH. This was a single-center study that included 182 patients who had cardiac output concurrently measured by DF and TD. Oxygen consumption was measured by indirect calorimetry. Agreement between DF and bolus TD cardiac output was assessed using Bland-Altman analysis. The median DF and TD cardiac outputs were 5.42 L/min (interquartile range [IQR] 3.90-7.41) and 4.10 L/min (IQR 3.47-5.10), respectively. Significant disagreement was observed with DF yielding higher cardiac output results than TD. Mean error was proportional to cardiac output (-3.75% at 3 L/min to +44.5% at 7 L/min), and limits of agreement were wide. Disagreement was increased by 19.2% in the presence of least moderate tricuspid regurgitation and by 16.0% in patients with atrial fibrillation. Among 152 patients with PH, hemodynamic classification discordance occurred in 18 (11.8%) patients. Disagreement between DF and TD was observed, which resulted in a discrepant hemodynamic classification in approximately 12% of patients. These techniques should, therefore, not be used interchangeably for serial surveillance, and without a clinical gold standard, a rationale exists for utilizing both methods concurrently in certain clinical situations.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Pulmonary Circulation
Pulmonary Circulation Medicine-Pulmonary and Respiratory Medicine
CiteScore
4.20
自引率
11.50%
发文量
153
审稿时长
15 weeks
期刊介绍: Pulmonary Circulation''s main goal is to encourage basic, translational, and clinical research by investigators, physician-scientists, and clinicans, in the hope of increasing survival rates for pulmonary hypertension and other pulmonary vascular diseases worldwide, and developing new therapeutic approaches for the diseases. Freely available online, Pulmonary Circulation allows diverse knowledge of research, techniques, and case studies to reach a wide readership of specialists in order to improve patient care and treatment outcomes.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信