Evaluation of a new Everolimus-coated balloon catheter in an in-vivo porcine peripheral venous model.

IF 1.2 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
Stavros Spiliopoulos, Lazaros Reppas, Nikolaos Giannikas, Panagiotis Kitrou, Michail Theofanis, Michail Karpetas, Anargyros N Moulas, Ioannis Paraskevopoulos, Amalia I Moula, Kechagias Ioannis, Dimitrios Karnabatidis
{"title":"Evaluation of a new Everolimus-coated balloon catheter in an in-vivo porcine peripheral venous model.","authors":"Stavros Spiliopoulos, Lazaros Reppas, Nikolaos Giannikas, Panagiotis Kitrou, Michail Theofanis, Michail Karpetas, Anargyros N Moulas, Ioannis Paraskevopoulos, Amalia I Moula, Kechagias Ioannis, Dimitrios Karnabatidis","doi":"10.1186/s42155-025-00530-5","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The venous uptake following the application of Everolimus-coated balloons is under reported. We evaluated the feasibility, safety, and Everolimus (EVR) deliverability of a novel non-commercially available Everolimus-Coated Balloon (ECB) catheter in a swine healthy peripheral vein model.</p><p><strong>Methods: </strong>In total 12 ECBs (5.0 μg/mm<sup>2</sup>) were inflated in 12 venous segments. The primary feasibility endpoint was the successful application of the ECB at the target venous sites. The primary efficacy endpoint was the successful drug uptake by the target venous tissue at 24 h and 7 days, assessed by High Performance Liquid Chromatography combined with tandem mass spectrometry. The primary safety endpoint was freedom from major adverse events.</p><p><strong>Results: </strong>Everolimus was detected in 10 out of 12 (83.33%) tissue samples (all six tissue samples at 24 h post-intervention and in four out of six samples at 7 days). The mean weight of the examined tissue was 0.20604 ± 0.29822 g (range: 0.37475-0.02229 g). The average EVR tissue content detected at 24 h (135.67 ± 204.95 μg/g) was numerically superior, but non-statistically significant to the that detected 7 days post-procedure (96.85 ± 110.89 μg/g). The average quantity of EVR on the balloon after retrieval was 33.9% of the initial drug dose. No adverse events were recorded, and no abnormalities were noted during autopsy.</p><p><strong>Conclusions: </strong>The newly developed ECB successfully delivered Everolimus within the healthy venous wall. No adverse events were noted at a short-term follow-up.</p><p><strong>Relevance statement: </strong>These safety and feasibility results justify further experimental and clinical research to demonstrate the safety efficacy the specific balloon catheter.</p>","PeriodicalId":52351,"journal":{"name":"CVIR Endovascular","volume":"8 1","pages":"16"},"PeriodicalIF":1.2000,"publicationDate":"2025-02-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11867998/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"CVIR Endovascular","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s42155-025-00530-5","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The venous uptake following the application of Everolimus-coated balloons is under reported. We evaluated the feasibility, safety, and Everolimus (EVR) deliverability of a novel non-commercially available Everolimus-Coated Balloon (ECB) catheter in a swine healthy peripheral vein model.

Methods: In total 12 ECBs (5.0 μg/mm2) were inflated in 12 venous segments. The primary feasibility endpoint was the successful application of the ECB at the target venous sites. The primary efficacy endpoint was the successful drug uptake by the target venous tissue at 24 h and 7 days, assessed by High Performance Liquid Chromatography combined with tandem mass spectrometry. The primary safety endpoint was freedom from major adverse events.

Results: Everolimus was detected in 10 out of 12 (83.33%) tissue samples (all six tissue samples at 24 h post-intervention and in four out of six samples at 7 days). The mean weight of the examined tissue was 0.20604 ± 0.29822 g (range: 0.37475-0.02229 g). The average EVR tissue content detected at 24 h (135.67 ± 204.95 μg/g) was numerically superior, but non-statistically significant to the that detected 7 days post-procedure (96.85 ± 110.89 μg/g). The average quantity of EVR on the balloon after retrieval was 33.9% of the initial drug dose. No adverse events were recorded, and no abnormalities were noted during autopsy.

Conclusions: The newly developed ECB successfully delivered Everolimus within the healthy venous wall. No adverse events were noted at a short-term follow-up.

Relevance statement: These safety and feasibility results justify further experimental and clinical research to demonstrate the safety efficacy the specific balloon catheter.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CVIR Endovascular
CVIR Endovascular Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
2.30
自引率
0.00%
发文量
59
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信