Evaluation of two stable internal fixation techniques in mandibular ramus sagittal osteotomy: a three-dimensional finite element study.

IF 1.7 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
Kaline de Moura Silva, Leonardo Mendes Ribeiro Machado, Milena Gomes Melo Leite, Pedro Yoshito Noritomi, Giorge Pessoa de Jesus, Andrezza Lauria de Moura
{"title":"Evaluation of two stable internal fixation techniques in mandibular ramus sagittal osteotomy: a three-dimensional finite element study.","authors":"Kaline de Moura Silva, Leonardo Mendes Ribeiro Machado, Milena Gomes Melo Leite, Pedro Yoshito Noritomi, Giorge Pessoa de Jesus, Andrezza Lauria de Moura","doi":"10.1007/s10006-025-01357-z","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate and compare, using finite elements three-dimensional (3D) analysis, two techniques of stable internal fixation in 2 patterns of sagittal split ramus osteotomy (SSRO) and the repercussions of occlusal load distribution in the postoperative period.</p><p><strong>Methods: </strong>A 3D finite element model of a hemimandible was created. The models were divided into 2 split patterns of SSRO advanced 5 mm forward, a split pattern (1) following the Epker osteotomy design and another split pattern (2) following Posnick osteotomy design, simulated by CAD (Computer Aided Engineering) Rhinoceros 3D<sup>®</sup>. Two internal fixation techniques were simulated by HyperMesh: A- one titanium miniplate of the Arnett system (1 mm) for orthognathic surgery fixed with four monocortical screws; B- one titanium plate fixed with four monocortical screws and one bicortical screw. Resistance, stress and displacement were analyzed applying a 200 N vertical load to the occlusal surface region of the mandibular first molar and a 100 N to the incisal surface of the mandibular central incisor.</p><p><strong>Results: </strong>The results were presented through the von Mises stress analysis. A difference in the displacement of the models fixed with only one miniplate and four monocortical screws was observed. The models with split pattern (2) presented smaller displacements when compared to the split pattern (1). For metallic components, the split pattern (2) exhibits lower strain values, although it has no significant difference.</p><p><strong>Conclusion: </strong>The fixation technique B proved to be more rigid and lower stress values both in the bone and in the plate, as well as lower deformation and displacements were shown in comparison to fixation technique A for all mandibular movements and forces.</p>","PeriodicalId":47251,"journal":{"name":"Oral and Maxillofacial Surgery-Heidelberg","volume":"29 1","pages":"59"},"PeriodicalIF":1.7000,"publicationDate":"2025-02-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Oral and Maxillofacial Surgery-Heidelberg","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s10006-025-01357-z","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To evaluate and compare, using finite elements three-dimensional (3D) analysis, two techniques of stable internal fixation in 2 patterns of sagittal split ramus osteotomy (SSRO) and the repercussions of occlusal load distribution in the postoperative period.

Methods: A 3D finite element model of a hemimandible was created. The models were divided into 2 split patterns of SSRO advanced 5 mm forward, a split pattern (1) following the Epker osteotomy design and another split pattern (2) following Posnick osteotomy design, simulated by CAD (Computer Aided Engineering) Rhinoceros 3D®. Two internal fixation techniques were simulated by HyperMesh: A- one titanium miniplate of the Arnett system (1 mm) for orthognathic surgery fixed with four monocortical screws; B- one titanium plate fixed with four monocortical screws and one bicortical screw. Resistance, stress and displacement were analyzed applying a 200 N vertical load to the occlusal surface region of the mandibular first molar and a 100 N to the incisal surface of the mandibular central incisor.

Results: The results were presented through the von Mises stress analysis. A difference in the displacement of the models fixed with only one miniplate and four monocortical screws was observed. The models with split pattern (2) presented smaller displacements when compared to the split pattern (1). For metallic components, the split pattern (2) exhibits lower strain values, although it has no significant difference.

Conclusion: The fixation technique B proved to be more rigid and lower stress values both in the bone and in the plate, as well as lower deformation and displacements were shown in comparison to fixation technique A for all mandibular movements and forces.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Oral and Maxillofacial Surgery-Heidelberg
Oral and Maxillofacial Surgery-Heidelberg DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.20
自引率
5.60%
发文量
118
期刊介绍: Oral & Maxillofacial Surgery founded as Mund-, Kiefer- und Gesichtschirurgie is a peer-reviewed online journal. It is designed for clinicians as well as researchers.The quarterly journal offers comprehensive coverage of new techniques, important developments and innovative ideas in oral and maxillofacial surgery and interdisciplinary aspects of cranial, facial and oral diseases and their management. The journal publishes papers of the highest scientific merit and widest possible scope on work in oral and maxillofacial surgery as well as supporting specialties. Practice-oriented articles help improve the methods used in oral and maxillofacial surgery.Every aspect of oral and maxillofacial surgery is fully covered through a range of invited review articles, clinical and research articles, technical notes, abstracts, and case reports. Specific topics are: aesthetic facial surgery, clinical pathology, computer-assisted surgery, congenital and craniofacial deformities, dentoalveolar surgery, head and neck oncology, implant dentistry, oral medicine, orthognathic surgery, reconstructive surgery, skull base surgery, TMJ and trauma.Time-limited reviewing and electronic processing allow to publish articles as fast as possible. Accepted articles are rapidly accessible online.Clinical studies submitted for publication have to include a declaration that they have been approved by an ethical committee according to the World Medical Association Declaration of Helsinki 1964 (last amendment during the 52nd World Medical Association General Assembly, Edinburgh, Scotland, October 2000). Experimental animal studies have to be carried out according to the principles of laboratory animal care (NIH publication No 86-23, revised 1985).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信