Metal artifacts correction based on a physics-informed nonlinear sinogram completion model.

IF 3.3 3区 医学 Q2 ENGINEERING, BIOMEDICAL
Shuqiong Fan, Mengfei Li, Chuwen Huang, Xiaojuan Deng, Hongwei Li
{"title":"Metal artifacts correction based on a physics-informed nonlinear sinogram completion model.","authors":"Shuqiong Fan, Mengfei Li, Chuwen Huang, Xiaojuan Deng, Hongwei Li","doi":"10.1088/1361-6560/adbaad","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Metal artifacts seriously deteriorate CT image quality. Current metal artifacts reduction methods suffer from insufficient correction or easily introduce secondary artifacts. To better suppress metal artifacts, we propose a sinogram completion approach extracting and utilizing useful information that contained in the corrupted metal trace projections.</p><p><strong>Approach: </strong>Our method mainly contains two stages: sinogram interpolation by an improved normalization technique for initial correction and physics-informed nonlinear sinogram decomposition for further improvement. In the first stage, different from the popular normalized metal artifact reduction method, we propose a more meaningful normalization scheme for the interpolation procedure. In the second stage, instead of performing a linear sinogram decomposition as done in the physics-informed sinogram completion method, we introduce a nonlinear decomposition model that can accurately separate the sinogram into metal and non-metal contributions by better modeling the physical scanning process. The interpolated sinogram and physics-informed correction compensate each other to reach the optimal correction results.</p><p><strong>Main results: </strong>Experimental results on simulated and real data indicate that, in terms of both structures preservation and detail recovery, the proposed PNSC method achieves very competitive performance for metal artifacts reduction compared to existing methods.</p><p><strong>Significance: </strong>According to our knowledge, it's for the first time that a nonlinear sinogram decomposition model is proposed in the literature for metal artifacts correction. It might motivate further research exploring this idea for various sinogram processing tasks.</p>","PeriodicalId":20185,"journal":{"name":"Physics in medicine and biology","volume":" ","pages":""},"PeriodicalIF":3.3000,"publicationDate":"2025-02-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physics in medicine and biology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1361-6560/adbaad","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: Metal artifacts seriously deteriorate CT image quality. Current metal artifacts reduction methods suffer from insufficient correction or easily introduce secondary artifacts. To better suppress metal artifacts, we propose a sinogram completion approach extracting and utilizing useful information that contained in the corrupted metal trace projections.

Approach: Our method mainly contains two stages: sinogram interpolation by an improved normalization technique for initial correction and physics-informed nonlinear sinogram decomposition for further improvement. In the first stage, different from the popular normalized metal artifact reduction method, we propose a more meaningful normalization scheme for the interpolation procedure. In the second stage, instead of performing a linear sinogram decomposition as done in the physics-informed sinogram completion method, we introduce a nonlinear decomposition model that can accurately separate the sinogram into metal and non-metal contributions by better modeling the physical scanning process. The interpolated sinogram and physics-informed correction compensate each other to reach the optimal correction results.

Main results: Experimental results on simulated and real data indicate that, in terms of both structures preservation and detail recovery, the proposed PNSC method achieves very competitive performance for metal artifacts reduction compared to existing methods.

Significance: According to our knowledge, it's for the first time that a nonlinear sinogram decomposition model is proposed in the literature for metal artifacts correction. It might motivate further research exploring this idea for various sinogram processing tasks.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Physics in medicine and biology
Physics in medicine and biology 医学-工程:生物医学
CiteScore
6.50
自引率
14.30%
发文量
409
审稿时长
2 months
期刊介绍: The development and application of theoretical, computational and experimental physics to medicine, physiology and biology. Topics covered are: therapy physics (including ionizing and non-ionizing radiation); biomedical imaging (e.g. x-ray, magnetic resonance, ultrasound, optical and nuclear imaging); image-guided interventions; image reconstruction and analysis (including kinetic modelling); artificial intelligence in biomedical physics and analysis; nanoparticles in imaging and therapy; radiobiology; radiation protection and patient dose monitoring; radiation dosimetry
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信