{"title":"A new ultrasound-guided surgical technique to fix acute tibial posterior cruciate ligament avulsion fracture","authors":"Hao Luo,&nbsp;Lin-Feng Li,&nbsp;Song Han,&nbsp;Yu Pan,&nbsp;Fei-Ju Xu,&nbsp;Tao Liu","doi":"10.1002/jeo2.70191","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Purpose</h3>\n \n <p>This study aims to describe a novel minimally invasive technique for the treatment of acute tibial posterior cruciate ligament (PCL) avulsion fracture.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>This retrospective study included seven patients who underwent ultrasound-guided fixation for acute PCL tibial avulsion fractures by using an adjustable-loop device between January 2021 and January 2023. Before the surgery, the maximum diameter, area and displacement distance of the fragments were measured using computed tomography examination. All patients were followed up for at least 12 months, and clinical outcomes were assessed on the basis of range of motion, the International Knee Documentation Committee Score and the Lysholm score.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>For the seven patients, the mean maximum diameter, area and displacement distance of preoperative avulsion fragments were 12.7 mm (range, 9.0–48.3), 128 mm<sup>2</sup> (range, 63–256.2) and 5.9 mm (range, 3.8–7.2), respectively. These fractures were fixed using an adjustable-loop suspensory device under ultrasound guidance. Based on x-ray examination during the post-operative follow-up period, all patients had no fracture displacement and fracture unions were confirmed, with a mean union time of 10.28 ± 2.13 weeks (range, 8–14). Based on the knee function assessment at 12-month post-operative follow-up visit, all patients demonstrated excellent clinical outcomes.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>Ultrasound-assisted internal fixation using an adjustable-loop device demonstrated satisfactory clinical and radiographic results. This technique has the advantages of being minimally invasive, safe, stable, convenient to operate and thus could be considered as a feasible alternative for the treatment of acute tibial PCL avulsion fractures.</p>\n </section>\n \n <section>\n \n <h3> Level of Evidence</h3>\n \n <p>Level III.</p>\n </section>\n </div>","PeriodicalId":36909,"journal":{"name":"Journal of Experimental Orthopaedics","volume":"12 1","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2025-02-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/jeo2.70191","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Experimental Orthopaedics","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/jeo2.70191","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose

This study aims to describe a novel minimally invasive technique for the treatment of acute tibial posterior cruciate ligament (PCL) avulsion fracture.

Methods

This retrospective study included seven patients who underwent ultrasound-guided fixation for acute PCL tibial avulsion fractures by using an adjustable-loop device between January 2021 and January 2023. Before the surgery, the maximum diameter, area and displacement distance of the fragments were measured using computed tomography examination. All patients were followed up for at least 12 months, and clinical outcomes were assessed on the basis of range of motion, the International Knee Documentation Committee Score and the Lysholm score.

Results

For the seven patients, the mean maximum diameter, area and displacement distance of preoperative avulsion fragments were 12.7 mm (range, 9.0–48.3), 128 mm2 (range, 63–256.2) and 5.9 mm (range, 3.8–7.2), respectively. These fractures were fixed using an adjustable-loop suspensory device under ultrasound guidance. Based on x-ray examination during the post-operative follow-up period, all patients had no fracture displacement and fracture unions were confirmed, with a mean union time of 10.28 ± 2.13 weeks (range, 8–14). Based on the knee function assessment at 12-month post-operative follow-up visit, all patients demonstrated excellent clinical outcomes.

Conclusions

Ultrasound-assisted internal fixation using an adjustable-loop device demonstrated satisfactory clinical and radiographic results. This technique has the advantages of being minimally invasive, safe, stable, convenient to operate and thus could be considered as a feasible alternative for the treatment of acute tibial PCL avulsion fractures.

Level of Evidence

Level III.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Experimental Orthopaedics
Journal of Experimental Orthopaedics Medicine-Orthopedics and Sports Medicine
CiteScore
3.20
自引率
5.60%
发文量
114
审稿时长
13 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信